Renewable energy sources are connected to the grid through inverters, resulting in reduced grid inertia and poor stability. Traditional grid-connected inverters do not have the function of voltage and frequency regulation and can no longer adapt to the new development. The virtual synchronous generator (VSG) has the function of voltage and frequency regulation and has more outstanding advantages than the traditional inverter. Based on the principle of the VSG, the relationship between energy storage capacity, frequency response and output power of the VSG is derived, and the relationship between the virtual inertia coefficient, damping coefficient and frequency characteristics of the VSG and output power is revealed. The mathematical model is established and modeled using the Matlab/Simulink simulation software, and the simulation results verify the relationship between energy storage capacity and frequency response and the output power of the VSG.
EN
This paper proposes an electromechanical transient method to build a battery energy storage system-based virtual synchronous generator model, suitable for a large-scale grid. This model consists of virtual synchronous generator control, system limitation and the model interface. The equations of a second-order synchronous machine, the characteristics of charging/discharging power, state of charge, operating efficiency, dead band and inverter limits are also considered. By equipping the energy storage converter into an approximate synchronous voltage source with an excitation system and speed regulation system, the necessary inertia and damping characteristics are provided for the renewable energy power system with low inertia and weak damping. Based on the node current injection method by the power system analysis software package (PSASP), the control model is built to study the influence of different energy storage systems. A study on the impact of renewable energy unit fluctuation on frequency and the active power of the IEEE 4-machine 2-area system is selected for simulation verification. Through reasonable control and flexible allocation of energy storage plants, a stable and friendly frequency environment can be created for power systems with high-penetration renewable energy.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.