Vibration is a ubiquitous phenomenon that occurs in everyday life and people are exposed to it almost all the time. Most often, vibration is measured using electromechanical devices such as piezoelectric, piezoresistive, or capacitive accelerometers. However, attention should be paid to the limitations of such vibration sensors. They cannot operate in the presence of strong electromagnetic fields. Measurements with electromechanical devices require physical contact between the sensor and the vibrating object, which is not always possible due to the design of the sensor and device. The possibility of a non-contact vibration measurement in harsh environments is provided by the technology of interferometric fibre optic sensors. This paper reports the principle of operation, design aspects, experimentation, and performance of a Mach-Zehnder interferometric setup for the measurement of vibration frequency. There are different sensing arms implemented in the interferometer: single-mode, polarization-maintaining, and tapered optical fibre. The paper emphasises the simplicity of the set-up structure and the detection capabilities based on the interferometric sensing giving the possibility of constructing a commercial vibration sensor for all industry demands.
EN
The paper describes a system for monitoring and diagnosing a gantry. The main goal of the system is to acquire, visualize and monitor vibration levels of the gantry crucial elements. The system is also equipped with a computing and analytical part which enables predictive maintenance related to the vibration level assessment. The system architecture can be used in other applications too, i.e. those which require a wireless network of vibration sensors to carry out diagnostic tasks.
PL
W artykule przedstawiono system monitorowania i diagnostyki suwnicy bramowej. Głównym zadaniem systemu jest akwizycja, wizualizacja i monitorowanie poziomu drgań newralgicznych elementów suwnicy. System wyposażony jest również w część obliczeniowoanalityczną, umożliwiającą realizację zadań predykcyjnego utrzymania ruchu (ang. predictive maintenance) związanych z oceną poziomu drgań. Architektura systemu umożliwia wykorzystanie go również do innych zastosowań, w których dla realizacji zadania diagnostyki wymagana jest bezprzewodowa sieć czujników drgań.
PL
Przeanalizowano wyniki badań porównawczych różnych typów czujników stosowanych w pomiarach amplitudy drgań pióra łopatki sprężarki silników lotniczych w próbie zmęczeniowej. Zbadano czujniki: indukcyjny, pojemnościowy, wiroprądowy, laserowy oraz drgań. Scharakteryzowano je i przedstawiono ich wady. Zaprojektowano i wykonano dodatkowe oprzyrządowanie stanowiska badawczego, m.in. uchwyt mocujący.
EN
Results of comparison research of various sensors types used in the fatigue tests for aircraft engine compressor blade vibration amplitude measurement were analysed. Sensors under tests: inductive, capacitive, eddy-current, laser and vibration. Presented were sensors characteristics and their faults. Additional test stand instrumentation was designed and performed, including mounting bracket.
4
Content available remote Pełna kontrola nad drganiami
PL
Wznoszenie nowych obiektów w terenie zurbanizowanym stawia coraz więcej wyzwań przed inwestorami i wykonawcami prac budowlanych. Dla obu stron realizacja robót w ścisłej zabudowie miejskiej oznacza bowiem nie tylko istotne ograniczenia technologiczne, ale i odpowiedzialność za bezpośrednie sąsiedztwo prowadzonej budowy. W praktyce oddziaływanie budowy na otoczenie skutkuje powstaniem szeregu ryzyk: poczynając od strat wizerunkowych na skutek niepotrzebnych konfliktów z sąsiadami, na znaczących stratach materialnych, wynikających z opóźnień lub ewentualnych odszkodowań, kończąc. Coraz częściej na polskich placach budów pojawiają się jednak technologie, które ograniczają te ryzyka do minimum.
5
Content available remote Monitorowanie oddziaływań dynamicznych w sąsiedztwie budowy
PL
Ciągły w czasie, długoterminowy monitoring drgań istniejących obiektów zlokalizowanych w pobliżu prowadzonych prac budowlanych przynosi wymierne korzyści, zarówno w kontekście wzrostu bezpieczeństwa sąsiadujących obiektów, jak i w sensie ekonomicznym. Skuteczność prowadzonych pomiarów w zakresie realnej kontroli ryzyka wymaga przeanalizowania wielu czynników. Począwszy od doboru czujników oraz miejsc i sposobu ich instalacji na konstrukcji, przez zastosowanie urządzeń elektronicznych pozyskując dane z czujników, a na oprogramowaniu do analizy danych i informowania o zagrożeniach kończąc.
EN
The facilities loaded near the construction tend to vibrate and that presents a great risk. Long-term monitoring of those vibrations brings measurable benefits by increasing security of neighbouring facilities. It is also very profitable. For the real risk control measurements to be effective, there are some requirements to be met. e.g. the appropriate selection of the sensors, the place and method of their installation, the use of electronic data acquisition devices or the data analysis software.
EN
Foaming slag in electric arc furnaces is one of the topics that engage many steelwork operators around the world. Since the 80’s a variety of methods, such as FFT analysis of the electric current or also directional microphone investigations, have not led to successful detection of the foaming slag height and nor, therefore, to complete automation of the electric arc furnace process. Therefore Siemens Industry Sector, Metals Technologies Division developed a new possibility to detect the level or at least the quality of foaming slag in the furnace. In different publications [1, 2, 3, 4] the topic of this special development was reported. In February 2005 research and development was launched to investigate detectability by means of structure-borne sound. Second step was to develop a control algorithm for the injection of carbon. The successful commissioning of the carbon control at the arc furnace No.1 of Lechstahlwerke GmbH led to further steps: The first results, details are explained later in the paper, are extremely good, so that an entirely full automated arc furnace operation seems to be possible in mid time range from the authors side of view. Siemens is setting up a research and development program for the next 3 years.
PL
Pienienie się żużla w elektrycznym piecu łukowym jest jednym z tematów, który angażuje wielu stalowników na całym świecie. Od lat osiemdziesiątych różnorodność metod, takich jak analiza FFT prądu elektrycznego, czy badania mikrofonem kierunkowym, nie doprowadziły do poprawnej detekcji wysokości pieniącego się żużla, ani udoskonalenia automatyzacji procesu elektrometalurgicznego. Dlatego Siemens Industry Sector, Metals Technologies Division opracował nową możliwość detekcji poziomu przy naj- mniejszej jakości pieniącego się żużla w piecu. W lutym 2005 roku rozpoczęto badania i rozwój wykrywalności z użyciem dźwięku structure-borne. Drugim krokiem było opracowanie algorytmu sterowania wdmuchiwaniem węgla. Sterowanie wdmuchiwaniem węgla z sukcesem zostało prze- prowadzone w stalowni Lechstahlwerke GmbH. Pierwsze wyniki są niezwykle dobre, więc w pełni automatyczne sterowanie piecem łukowym w trakcie procesu wydaje się możliwe. Siemens powołał program badań i rozwoju na najbliższe trzy lata.
PL
W niniejszej pracy zaprezentowana zostanie prototypowa konstrukcja światłowodowego czujnika drgali przeznaczonego do diagnostyki maszyn i urządzeń elektroenergetycznych. Wykorzystanie włókna światłowodowego jako elementu czujnikowego pozwoliło na stworzenie prostej konstrukcji, która charakteryzuje się odpornością na zakłócenia elektromagnetyczne, iskrobezpicczeństwem oraz izolacją galwaniczną. Dzięki swoim zaletom niniejszy czujnik może być stosowany w miejscach, gdzie instalacja czujników elektrycznych nie jest możliwa. Wstępne pomiary porównawcze i testowe potwierdziły skuteczność opracowanej konstrukcji.
EN
The prototype construction of the optical fiber vibration sensor for machines diagnostic and monitoring is herein described. The optical fiber was used as both: the sensor, and signal transmission channel. Thereby such features as: electromagnetic noise immunity, electrical isolation of the sensor from the measuring unit and spark-safety are fulfilled. Due to mentioned advantages, the measurements can be performed in environment where electrical methods couldn't be applied. Preliminary tests and measurements confirmed the efficiency of the sensor.