1
EN
The size of all sensible heat balance components in livestock building varies in time, because it depends on time-varying weather factors. On the example of two buildings, sensible heat balance was shown on a daily basis. Measurements carried out in winter and spring in two livestock buildings with usable attics included measurements of air temperature and humidity inside and outside, air velocity in ventilation channels, and wind speed. Measuring devices were designed to record the results of measurements at intervals of 300s. During each such time interval, sensible heat losses by ventilation, heat losses by permeation through the barrier construction, and the amount of sensible heat produced by the animals were calculated. The results of measurements were shown in graphs. The study is important for the development of animal livestock building.
PL
Wielkość wszystkich składników bilansu ciepła jawnego w budynku inwentarskim jest zmienna w czasie ponieważ zależy od zmiennych w czasie czynników pogodowych. Na przykładzie dwóch budynków przedstawiono bilans ciepła jawnego w ujęciu dobowym. Pomiary przeprowadzone w zimie i na wiosnę w dwóch budynkach dla bydła z poddaszem użytkowym obejmowały pomiary temperatury i wilgotności powietrza wewnętrznego i zewnętrznego, prędkości przepływu powietrza w kanałach wentylacyjnych oraz ciśnienia atmosferycznego i prędkości wiatru. Urządzenia pomiarowe zostały zaprojektowane na rejestrację wyników pomiarów w odstępach co 300 s. W każdym z takim przedziale czasowym obliczone zostały straty ciepła jawnego drogą wentylacji, straty ciepła drogą przenikania przez przegrody budowlane oraz ilości ciepła jawnego produkowanego przez zwierzęta. Wyniki pomiarów i obliczeń przedstawiono na wykresach.
PL
W pracy podjęto próbę wyznaczenia terenów stanowiących potencjalne korytarze przewietrzające warunkujące prawidłowe funkcjonowanie systemu aeracyjnego miasta. Badanie zostało przeprowadzone przy użyciu jednej z najpopularniejszych metod – morfometrycznej, ze względu na niski koszt pozyskania danych oraz wysoką precyzję otrzymywanych wyników. Z uwagi na dominujący kierunek napływu wiatru, analizami objęto dowietrzny fragment miasta Łodzi. Pierwszy etap opracowania objął analizę podstawowych parametrów szorstkości terenu, tj. chropowatości podłoża (zo), przemieszczenia płaszczyzny zerowej (zd) oraz porowatości w obrębie warstwy dachowej (P). Na podstawie uzyskanych wyników oraz przyjętych kryteriów prawidłowego funkcjonowania korytarzy przewietrzających wyznaczono osiem obszarów swobodnego napływu powietrza do miasta.
EN
The aim of the paper was an indication of potential ventilation paths which affect proper functioning of the cities aerial system. The research was conducted using the most popular method – morphometric for the sake of low cost data gathering and high precision of final results. Due to the wind’s dominant direction, an analysis covered a windward part of Lodz. The first part of the research included an analysis of the basic roughness parameters such as: roughness length (zo), zero plane displacement height (zd) and porosity of the urban canopy layer (P). Based on the obtained results and taking into account ventilation paths criteria eight areas were designated which provide a free flow of air to the city.
PL
W artykule omówiony został system wentylacji w środkach komunikacji, w którym można zastosować układ zawierający kanały wentylacyjne wyłożone od wewnątrz warstwą fotoaktywną, która reaguje na podające światło stając się bakteriobójczą.
EN
The model of ventilation channel with internal layer which becomes germicidal influenced by the light has been presented. The results is concerning the channel with rectangular cross section.
4
Content available remote Badanie wpływu wykształceń na suficie na czas zadziałania czujek pożarowych
PL
W artykule zaprezentowano metodykę pomiarów oraz wyniki badań wpływu wykształceń na suficie na czas detekcji czujek pożarowych. W badaniach wykorzystano stanowisko wyposażone w przeszkodę w postaci kanału wentylacyjnego, umożliwiające dokonywanie pomiarów czasu zadziałania czujek w skali rzeczywistej. Badania wykonano podczas spalania płomieniowego drewna sosnowego. Na podstawie przeprowadzonych analiz stwierdzono negatywny wpływ obecności wykształceń na suficie na zdolność detekcyjną czujek.
EN
In this paper the methodology of measurements and results of the examination of the impact of ceiling obstructions on the response times of fire detectors was presented. In the research a measuring chamber equipped with an obstacle in form of the ventilation channel, allowing to make measurements of the response time of detectors in real scale was used. Measurements were performed during the flame combustion of the pine wood. On the basis of the analyzes, a negative impact of the presence of ceiling obstructions on the response times of detectors was stated.
EN
The aim of this article to present of research results of microclimate parameters in barns with different gravitational ventilation systems and comparison of efficiency of these systems. Two tied-up and three loose-housing barns for dairy cows and one for beef cattle were researched. Tied-up barns had functional attic and duct ventilation, in barns with loose housing systems there were skylights with roof ridge gap. In stalls with ventilation by vertical channels there was not sufficient area of air inflow and outflow. The negative consequence of this was overcoming of recommended internal relative humidity of air (80%) in these stalls. In non-littered barns, with roof- ridge gap ventilation, temperature of air exceeded recommended values of 25oC. The luminance of daily light in stalls with functional attic was below of minimal level, which was described by standards (100 lx).
PL
Celem niniejszego artykułu jest przedstawienie wyników badań parametrów mikroklimatu w oborach z dwoma różnymi systemami wentylacji grawitacyjnej i porównanie skuteczności tych systemów. Zbadano po dwie obory stanowiskowe i wolnostanowiskowe dla krów mlecznych oraz jedną dla bydła mięsnego. Obory stanowiskowe posiadały poddasze użytkowe z wentylacją kanałową, natomiast w pozostałych oborach był świetlik ze szczeliną kalenicową. W oborach z wentylacją pionowymi kanałami nie była zapewniona odpowiednia powierzchnia nawiewu i wywiewu. Negatywnym tego skutkiem było przekroczenie zalecanych wartości wilgotności względnej powietrza (80%) w tych oborach. Temperatura w oborach bezściółkowych z wentylacją kalenicową przekraczała zalecane standardami wartości (25oC). Natężenie oświetlenia dziennego, w oborach z poddaszem użytkowym było poniżej minimalnego poziomu określonego standardami (100 lx).
PL
Analizie i opisowi poddano poszczególne elementy składające się na opis całościowy począwszy od modelu matematycznego opisywanego zjawiska łącznie z wyborem hipotezy zamykającej przez budowę warstwy przyściennej, narzucenie warunków brzegowych, budowę i dekompozycję geometrii wraz z opisem jej dyskretyzacji. Model został poddany walidacji na stanowisku pomiarowym, a wyniki eksperymentu zestawiono z obliczeniami numerycznymi na odpowiednich wykresach.
EN
An analysis and comprehensive description are presented concerning the phenomenon being described with its respective elements. The description starts from the mathematical model and includes a choice of the closing hypothesis, construction of the boundary layer and assumption of boundary conditions, the structural geometry and its decomposition with the description of its digitalisation. The model has been validated at the test stand. The results of the experiment were compared with numerical calculations in respective diagrams.
PL
Przeprowadzono badania eksperymentalne procesu wymiany ciepła przez konwekcję podczas ruchu burzliwego powietrza w kanałach przewodów wentylowanych. Otrzymana zależność kryterialna, dająca możliwość obliczania średnich wartości współczynnika przejmowania ciepła, a odpowiednie, ilość strumienia ciepła podczas ruchu burzliwego powietrza w kanałach przewodów wentylowanych.
EN
Experimental investigations of the convectional heat exchange process at air turbulent movement in the channels of ventilated spaces have been carried out. Criterial dependency that gives a possibility to determine an average value of heat-returning coefficient, and as a result the value of heat flow, has been obtained.