Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  vacuum pump
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Accurate temperature prediction is vital for the canned permanent magnet synchronous motor (CPMSM) used in the vacuum pump, as it experiences severe heating. In this paper, a novel motor temperature calculation method is proposed, which takes into account the temperature impact on the heat transfer capacity. In contrast to existing electromagnetic-thermal coupled calculation methods, which solely address the temperature effect on the motor electromagnetic field, the proposed method comprehensively considers its impact on motor losses, permanent magnet magnetic properties, thermal conductivity, and heat dissipation ability of motor components, resulting in a motor temperature simulation that closely resembles the actual physical process. To verify the reliability of the proposed temperature calculation method, a 1.5 kW CPMSM was chosen as the research subject. The method was used to analyze the temperature distribution characteristics of the motor and assess the impact of ambient temperature on motor temperature rise. Furthermore, a prototype was fabricated, and an experimental platform was established to test the motor temperature. The results demonstrate good agreement between the calculated results obtained using the proposed method and the experimental data. This research not only provides a theoretical foundation for optimizing the design of the CPMSM but also provides valuable insights into its operational safety and reliability.
PL
W pracy przedstawiono podstawowe systemy kanalizacji podciśnieniowej i przeciętne jednostkowe zużycie energii elektrycznej wg danych literaturowych i badań własnych. Stwierdzono, że energochłonność systemów kanalizacji próżniowej jest stosunkowo wysoka (200-400 kWh/a na jedno przyłącze), lecz mocno zróżnicowana (od 0,2 kWh/m3 do kilku kWh/m3), co wskazuje na duże możliwości jej zmniejszenia. Wyszczególniono cztery obszary redukcji kosztów transportu: koncepcję, projekt, wykonawstwo i eksploatację. Wszystkie te obszary mogą w różnym stopniu decydować o mocy zainstalowanej i zapotrzebowaniu na energię do transportu ścieków w kanalizacji podciśnieniowej, ale największe efekty może przynieść poprawa sprawności pomp próżniowych i sterowanie czasem otwarcia zaworów opróżniających.
EN
The paper presents basic vacuum sewerage systems and average unit electric energy consumption according to the literature data and own research. It was found that the energy consumption of vacuum sewage systems is relatively high (200-400 kWh/a per one connection), but highly diversified (from 0.2 kWh/m3 to several kWh/m3), which indicates great opportunities for its reduction. Four areas of transport cost reduction were specified: concept, design, construction, operation and maintenance. All these areas may, to a certain degree, determine the installed electric power and energy demand for the transport of wastewater in a vacuum sewerage system, but the greatest effects can be achieved by improving the energy efficiency of vacuum pumps and controlling the opening time of vacuum valves.
EN
When the traditional multi-motor speed synchronous control strategy is applied to the vacuum pump system, it is prone to the drawbacks of large synchronization error. In this paper, a simplified mathematical model of the motor for a vacuum pump is established and the transfer function is introduced, which weakens the multivariable, strong coupling and nonlinear characteristics of the motor system. According to the basic principle of the relative coupling control strategy, the neural network Proportion Integration Differentiation (PID) is introduced as a speed compensator in this system. It effectively improves the synchronization and anti-interference ability of the multi motor
EN
Rotary vane vacuum pumps are devices widely used in various types of industries. A three-phase electric motor, which is a usual drive source in this group of devices, propels rotor, which is eccentric placed in the cylinder. The combination of this arrangement, between cylinder and rotor, with centrifugal force, forces the vanes to move out and into its slots milled in the rotor. As a result, the increase and decrease of the inter-vane volume occur, causing the air to be sucked into the pump. Due to improper exploitation, there is a possibility of a mechanical damage to the vane, and in some cases the vane can fall out of its groove, what leads to catastrophic failure. The article presents a new method for diagnostics of vanes, based on the observation and analysis of a pressure signal, generated by a rotary vane vacuum pump.
EN
Unlike conventional fresh water producing systems, from saline or brackish water, the innovative solar water producing systems are efficient and effective. Experiments were conducted on two identical roof-type solar stills and simultaneously tested under the same weather conditions. One of these stills was modified by integrating a vacuum pump to lower the pressure inside while the other still was used as a reference unit. Different concentrations of Al2O3 nanoparticles were chosen, 0.2%, 0.4%, and 0.6%, and used with water inside the modified still. It was verified that the modified still, without nanoparticles, yields 34.84% more production than the conventional still. In addition, the modified still with a 0.4% of Al2O3 nanoparticles produced the highest percentage of distilled water, 44.42% in comparison to the one without the use of Al2O3 nanoparticles, followed by 37.94% and 24.07% for 0.6% and 0.2% of Al2O3 nanoparticles, respectively.
6
Content available remote Możliwości odzyskiwania energii cieplnej w procesie doju krów
PL
Przeprowadzono badania nad możliwością wykorzystania energii cieplnej zawartej w wydmuchiwanym powietrzu z pompy próżniowej dojarki do ogrzewania hali udojowej. Ze względu na małą moc cieplną (1,8 kW) ograniczono nadmuch tylko do kanału dla obsługi dojarni. Dzięki dodatkowym filtrom w dostarczanym powietrzu nie stwierdzono śladów oleju.
EN
The investigation into possibility of utilization the thermal energy contained in the air blowing from milker vacuum pump to heat milking hall, was executed. Because of the low thermal power (1,6 kW) demister was only reduced to pit for milker operators. Thanks to additional filters there was no traces of oil found in delivered air.
PL
W poprzedniej części artykułu omówiliśmy rynek bębnów inwersyjnych do renowacji przyłączy kanalizacyjnych. Kolejnymi bardzo ważnymi urządzeniami potrzebnymi do prawidłowego przygotowania rękawa są mieszalniki do żywic, pompy próżniowe, rampy przesączeniowe z walcami kalibrującymi, urządzenia do podgrzewania wody.
8
Content available remote Metody wymiarowania systemów kanalizacji podciśnieniowej
PL
W artykule omówiono metody wymiarowania systemu kanalizacji podciśnieniowej wg wytycznych polskich, niemieckich i amerykańskich. Dokonano porównania tych metod na podstawie przeprowadzonych obliczeń. Dla tych samych danych, otrzymano różne wyniki obliczeń. Brak jest spójnych wytycznych wymiarowania systemu kanalizacji podciśnieniowej.
EN
The paper describes a design method of vacuum sewer system according to Polish, German, and USA instructions. The methods were compared on the basis made calculations. For the same data obtained different results. It lacks of connectivity instructions to design of vacuum sewer system.
PL
Opisano projekty konstrukcji nowo opracowanych pomp jonowo-sorpcyjnych typu PJ-50 i PJ-400. Przy opracowaniu pomp wykorzystano wyniki eksperymentalne oraz wyniki symulacji obliczeniowych zjawisk zachodzących w układach katodowo-anodowych. Określono czynniki wpływające na efektywność pompowania gazów. Pompy PJ-50 i PJ-400 wyposażone są w zróżnicowane układy anodowo-katodowe z katodami płaskimi i modyfikowanymi oraz wkłady geterowe typu NEG firmy SAES. Pompa PJ-400 wyposażona jest dodatkowo w wymrażarkę chłodzoną ciekłym azotem lub wodą oraz w sześcioprętowy sublimator tytanowy.
EN
New construction design of ion sorption pumps: PJ-50 and PJ-400 is presented. Construction is based on experimental data as well as computer simulations of the physical processes present in Penning discharge systems. The presented pumps are equipped with various size discharge cells and different types of cathodes. In addition PJ-400 model has cryogenic shroud and six-rod titanium sublimator. Both pumps are equipped with SAES NEG getters.
PL
W pracy zaprezentowano numeryczną metodę wyznaczania szybkości pompowania pompy jonowo-sorpcyjnej. Obliczeń dokonano przy pomocy metody elementów skończonych zaimplementowanej w oprogramowaniu ANSYS 5.3 w celu optymalizacji konstrukcji pomp ze względu na szybkość pompowania. Badano rozkład potencjału oraz rozkład gęstości prądu jonowego wewnątrz komórki wyładowczej. Parametrami były: pole magnetyczne - do 1 ,5 T, potencjał anody - do 7 kV, średnica komórki wyładowczej - do 24 mm. Obliczenia szybkości pompowania dokonywano po przeprowadzeniu symulacji procesu rozpylania jonowego powierzchni katody.
EN
A numerical calculation of ion pump's pumping speed is presented. Finite element method implemented in ANSYS 5.3 code is used to optimise the construction parameters of ion sorption pumps. The method is based on simulation of potential distribution and ion bombardment current distribution within the discharge cell. The input parameters for the simulation were: magnetic field up to 1.5 T, anode potential up to 7 kV, dischange cell diameter up to 24 mm. The results as well as sputtering simulation data led us to calculate pumping speed of the analysed systems.
first rewind previous Strona / 1 next fast forward last