The study shown in this paper is concerned with the two-star asynchronous motor, and this motor is from the family of six-phase induction motors, which has many advantages in the industrial world. The featured in this article is the mathematical model of the double star motor by adopting the spatial harmonics of the inductance distribution on the squirrel-cage rotor bars and calculating the different inductances following the modified winding function approach (MWFA). Then we care about the control systems for this motor, especially the PWM command, by controlling a hexagonal inverter that feeds the DSAM. Finally, we make a preferential comparison between the two types of direct and indirect PWM control according to various operating circumstances, including load, torque, and speed fluctuations, considering the impact of spatial harmonics, to find out the best between them for this type of engine.
PL
Badanie przedstawione w tym artykule dotyczy dwugwiazdkowego silnika asynchronicznego, a ten silnik pochodzi z rodziny sześciofazowych silników indukcyjnych, która ma wiele zalet w świecie przemysłowym. W tym artykule omówiono model matematyczny silnika z podwójną gwiazdą, przyjmując harmoniczne przestrzenne rozkładu indukcyjności na prętach wirnika klatkowego i obliczając różne indukcyjności zgodnie z podejściem zmodyfikowanej funkcji uzwojenia (MWFA). Następnie dbamy o układy sterowania dla tego silnika, zwłaszcza polecenie PWM, sterując heksagonalnym falownikiem, który zasila DSAM. Na koniec dokonujemy preferencyjnego porównania między dwoma rodzajami bezpośredniego i pośredniego sterowania PWM w zależności od różnych okoliczności roboczych, w tym wahań obciążenia, momentu obrotowego i prędkości, biorąc pod uwagę wpływ harmonicznych przestrzennych, aby znaleźć najlepsze między nimi dla tego typu silnik.
EN
The article analyzes existing methods of diagnosing power transformers (PTs). The technique of experiment planning using D-optimal plans is investigated. According to the results of the study, a D-optimal plan of the frequency response measurements was created, which defines the algorithm of the studies. On the example of PT type TMG 1000/10 it is determined that 13 measurements are required to evaluate the condition of the PT during the interpretation of the results of the frequency response measurements. The method of determining the average frequency characteristic of PT is given. This amplitude-frequency characteristic can be used to check the PT status and to detect damage at an early stage of their development.
PL
Artykuł analizuje istniejące metody diagnozowania transformatorów mocy (TM). Badana jest technika planowania eksperymentu z wykorzystaniem planów optymalnych. Zgodnie z wynikami badań opracowano optymalny D-plan pomiarów odpowiedzi częstotliwościowej, który określa algorytm badań. Na przykładzie TM typu TMG 1000/10 ustalono, że do oceny stanu TM podczas interpretacji wyników pomiarów odpowiedzi częstotliwościowej potrzeba 13 pomiarów. Podano metodę wyznaczania charakterystyki średniej częstotliwości TM. Ta charakterystyka amplitudowo-częstotliwościowa może być u żywana do sprawdzania stanu TM i wykrywania uszkodzeń na wczesnym etapie ich rozwoju.
3
Content available remote Zastosowanie algorytmów do interpretacji wyników FRA
PL
W artykule przedstawiono porównanie najczęściej spotykanych w literaturze wzorów do interpretacji wyników uzyskanych przy pomiarach metodą analizy odpowiedzi częstotliwościowej stosowanej do diagnostyki transformatorów energetycznych. Kontrolowane deformacje wprowadzone w uzwojenia transformatora oraz wykorzystanie dwóch układów pomiarowych wykazały znaczne różnice w możliwości wykrycia uszkodzeń.
EN
The paper presents a comparison of the most frequently used formulas for interpreting the results obtained with the frequency response analysis method used to diagnose of power transformers. Controlled deformations introduced into windings and the use of two measuring setups showed significant differences in the possibility of detecting damages.
PL
W artykule przedstawiono analizę wpływu parametrów uzwojeń na charakterystyki przełączalnych generatorów reluktancyjnych SRG, pracujących przy zmiennej prędkości, takich jak generatory wiatrowe. Celem badań jest określenie charakterystyki, dla której uzyskana zostanie maksymalna moc w zadanym zakresie prędkości. Badania przeprowadzono metodą symulacji komputerowej z wykorzystaniem modelu matematycznego maszyny reluktancyjnej, bazując na zmodyfikowanym obwodzie magnetycznym seryjnie produkowanego przełączalnego silnika reluktancyjnego. W ramach badań przeprowadzono optymalizację uzwojeń i parametrów sterowania. Dla uzyskanych modeli generatora wyznaczono charakterystyki mocy generowanej w funkcji prędkości. W dalszym etapie badań wykonano obliczenia parametrów opisujących poszczególne charakterystyki oraz przeprowadzono analizę uzyskanych wyników.
EN
The paper presents the influence of winding parameters on the characteristics of switched reluctance generators (SRG), operating at variable rotational speeds, such as in wind turbine generators. The aim of the research is to find a characteristic allowing for maximum power of the generator at a given speed range. The research was carried out with means of a computer simulation using a mathematical model of a reluctance machine, based on a modified magnetic circuit of a series production switched reluctance motor. Winding parameters as well as control parameters were optimized. For each achieved model the characteristics of generated power in function of speed were calculated. Additionally, the parameters describing each characteristics were calculated and achieved results were analyzed.
PL
Zaprezentowano klasyczną metodę pomiaru temperatury uzwojenia wirnika generatora synchronicznego oraz przeanalizowano jej błędy pomiarowe. W artykule opisano koncepcję, algorytm oraz badania innowacyjnej metody pomiaru temperatury uzwojenia wirnika w procesorze regulatora napięcia statycznego tyrystorowego układu wzbudzenia. Badania przeprowadzono w środowisku Matlab/Simulink. Nowa metoda pomiaru temperatury uzwojenia wirnika została opracowana przez Instytut Energetyki Oddział Gdańsk w ramach pracy statutowej.
EN
Presented is a classical method for measurement of a synchronous generator rotor winding temperature and analysed are its measurement errors. Described is an idea, algorithm and research on the innovative method for measurement of a generator rotor winding temperature in the processor of a static voltage regulator in a thyristor excitation system. Reasearch was conducted in the Matlab/Simulink environment. The new method of a rotor winding temperature measurement has been developed by the Instytut Energetyki Oddział Gdańsk as a part of its statutory activity.
6
Content available remote Powstawanie rezonansowych drgań uzwojeń w transformatorach energetycznych
PL
W pracy opisano metodykę obliczeń drgań uzwojeń w transformatorach energetycznych przy pomocy metody elementów skończonych 3D zarówno w dziedzinie elektromagnetycznej jak i mechanicznej. Obliczenia uwzględniają rzeczywistą geometrię uzwojeń oraz ich strukturę materiałową.
EN
The paper describes the calculation method of winding zone in power transformers which uses the 3D finite elements both in electromagnetic and in structural domain. Calculations take into account the realistic geometry and material structure of windings.
PL
Uszkodzenia rotorów silników elektrycznych mogą wynikać z wielu przyczyn powstających na etapach montażu oraz eksploatacji napędów elektrycznych. Uszkodzenia mechaniczne, elektryczne lub złożone powstają jednak najczęściej w wyniku nieprawidłowego użytkowania. Z punktu widzenia niezawodności układów napędowych stanowią one istotny element powodujący zwiększenie prawdopodobieństwa awarii.
PL
Zjawisko oddziaływania pola elektrycznego na cząstki pyłu zaobserwowano pod koniec XVIII wieku. Jednak pierwsze udane próby budowy elektrofiltrów przeprowadzono dopiero na początku XX wieku. Obecnie filtry elektryczne, zwane elektrofiltrami, to urządzenia elektrostatyczne. Ten typ filtrów jest stosowany do odpylania pyłów w przemyśle hutniczym, wydobywczym i energetycznym. Chociaż charakteryzują się one dużą skutecznością odpylania (nawet powyżej 99%), nie znajdują jednak zastosowania w obiektach, w których pyły mają charakter wybuchowy, np. pyły w młynach, kaszarniach itp. W tej gałęzi przemysłu powszechnie stosowane są filtry tkaninowe. Elektrostatyczne oczyszczanie gazów jest w dalszym ciągu dynamicznie rozwijającą się technologią. W połączeniu z technologiami usuwania zanieczyszczeń stanowi z pewnością podstawę dalszego rozwoju elektrofiltrów. W artykule przedstawiono propozycję wykorzystania uzwojenia bifilarnego do odpylania pyłów wybuchowych.
EN
The article presents the proposal to use bifilar winding for extraction of explosive dusts. In the process of cleaning, grinding and transporting grain in elevators, warehouses and mills are generated large amounts of dust. Accordingly, the explosion dangerous concentrations of dust are formed in both the cleaning and the grinding grain. Bifilar windings with voltage supplied DC or AC generates heterogeneous electric field around. This property of bifilar winding can be used to capture particulate matter organic of explosive origin.
9
Content available remote Badanie izolacji zwojowej transformatorów prądem stałym
PL
W artykule przedstawiono koncepcję badań diagnostycznych izolacji zwojowej transformatorów i maszyn elektrycznych. Metoda ta polega na zasilaniu uzwojenia prądem stałym, następnie wyłączenie prądu i rejestracje indukowanego na uzwojeniu napięcia. Przebieg napięcia, w zależności od parametrów izolacji zwojowej, może być aperiodyczny lub periodyczny. Przedstawiono schematy ideowe wyłączników elektronicznych jednostopniowego i wielostopniowych oraz przykładowe przebiegi zarejestrowanego napięcia, po wyłączeniu prądu stałego, na transformatorze olejowym o mocy 400 kVA i transformatorze suchym 800 kVA.
EN
The article presents the idea of diagnostic tests of winding-isolation in transformers and in electrical machines. In this method a direct current is feeding the winding, next the current is switched off and the voltage induced in the winding is being recorded. The Oscillations/wave of voltage - depending on the parameters of the winding insulation - can be aperiodic or periodic. Schematic diagrams of electronic switches both single-speed and multi-speed are presented in this article, as well as sample Oscillations/wave of voltage, recorded - after the current is switched off - on oil-transformer with a capacity of 400 kVA and on 800 kVA dry-transformer.
Logistyka
|
2015
|
nr 3
2302--2311, CD 1
PL
W artykule przedstawiono metodę analizy wibroakustycznej drgań konstrukcji transformatora rejestrowanych akcelerometrem przytwierdzonym do kadzi. Prezentowana metoda opiera się na dwóch założeniach: w stanie ustalonym bez obciążenia źródłem wibracji jest rdzeń, w stanie nieustalonym po włączeniu zasilania drgania spowodowane są przez uzwojenia zasilające i rdzeń. W stanie ustalonym sygnał z akcelerometru analizowany jest w dziedzinie częstotliwości, a w stanie nieustalonym – w dziedzinie częstotliwości i czasu. W pracy przedstawiono podstawy teoretyczne zaproponowanych metod analizy sygnału wibroakustycznego oraz wyniki eksperymentalnych pomiarów na obiekcie rzeczywistym. Wykonane badania eksperymentalne potwierdziły wysoką skuteczność zaproponowanych algorytmów analizy sygnału wibroakustycznego.
EN
This paper presents a technique of vibroacoustic analysis of transformer mechanical condition, based on vibration measurement, using an accelerometer attached to the transformers tank. Presented method is based on two assumptions: 1. in no-load steady-state, the source of vibrations is the core, 2. in transient state, after power on, the vibrations are caused by the power winding and core. In the steady-state the signal from the accelerometer is analyzed in the frequency domain and in the transient state - in the frequency and time domain. This paper presents a theoretical basis of proposed vibroacoustic signal analysis methods and the results of real object measurements. Performed and described experimental studies confirmed the high effectiveness of the proposed algorithms for vibroacoustic signal analysis.
11
Content available remote Analysis of thermal processes in oil distribution transformer
EN
Paper deals with the analysis of thermal processes in oil distribution transformers. By means of the mathematical analysis and experimental measurements it is possible to diagnose of power oil transformers in terms of mechanical strength of winding. Analysis of warming at varying loads is very importance, since allows determining the load capacity and overload of the transformer under various operating conditions and respecting the variable ambient temperature.
PL
Artykuł dotyczy analizy procesów termicznych w rozdzielczych transformatorach olejowych. Za pomocą analizy matematycznej I pomiarów doświadczalnych można dokonać diagnozy olejowych transformatorów mocy pod względem wytrzymałości mechanicznej uzwojenia. Analiza nagrzewania się uzwojeń przy zmiennych obciążeniach jest bardzo ważna, gdyż pozwala na określenie nośności i przeciążenia transformatora w różnych warunkach eksploatacji w odniesieniu do zmiennej temperatury otoczenia.
12
Content available Analiza przepięć w transformatorach energetycznych
PL
Transformatory energetyczne są narażone na oddziaływanie udarów napięciowych stosowanych do prób napięciowych oraz przepięć o zróżnicowanych przebiegach i wartościach maksymalnych w warunkach eksploatacji. Przepięcia zawierają zwykle składowe oscylacyjne tłumione o częstotliwościach zawartych w szerokich granicach i oddziałują na transformatory pomimo powszechnie stosowanej ochrony przepięciowej. Zjawiska przejściowe w transformatorach, wpływające na przebiegi i wartości maksymalne przepięć wewnętrznych, są zależne od reakcji uzwojeń na napięcia pojawiające się na zaciskach wejściowych. Analiza przepięć w transformatorach ma duże znaczenie dla oceny warunków pracy ich układów izolacyjnych i doskonalenia ich konstrukcji. W artykule przedstawiono analizę przepięć generowanych w uzwojeniu transformatora rozdzielczego przy oddziaływaniu napięć przejściowych o różnych przebiegach.
EN
Power transformers are subjected to action standard voltage strokes during voltage tests and overvoltages with different shapes and maximal values in exploitation. Overvoltages influence on transformers despite of overvoltage protection systems. Usually overvoltages contain oscillative dumped components with frequencies of wide ranges. Transient phenomena in transformers, which have influence on courses and maximal values of internal overvoltages, are dependent on the reaction of windings on transient voltages at input clamps of transformers. Analysis of overvoltages in transformers has important meaning for estimation of working conditions of insulation systems and improvement of its construction. Analysis of overvoltages generated in distribution transformers under action of transient voltages with different waveforms is presented in the paper.
PL
W artykule omówiono sposób odwzorowania uzwojeń maszyn i urządzeń elektrycznych wykonanych z cienkich przewodów. Zastosowano podejście wykorzystujące elektryczny potencjał wektorowy T0. Proponowane w pracy podejście polega na poszukiwaniu rozkładu wektora T0 w obrębie uzwojenia przy znanym jego rozkładzie na granicy podobszarów. Przy rozwiązywaniu równań zastosowano sformułowanie „singularne” polegające na rozwiązywaniu nieoznaczonego układu równań, które umożliwia uzyskanie szybszej zbieżności procesu obliczeniowego od procesu rozwiązywania układu równań oznaczonych uzyskanego poprzez narzucanie dodatkowego warunku kalibracji Coulomb’a. Przydatność zaproponowanego sposobu odwzorowania uzwojeń przetestowano na przykładzie cewki dwuwarstwowego uzwojenia stojana maszyny indukcyjnej wysokonapięciowej pracującej w warunkach kriogenicznych.
EN
In the paper the method of description of the electrical machine windings with stranded conductors has been presented. The approach using the electrical vector potential T0 has been applied. The proposed method bases on finding the distribution of vector potential T0 inside the winding region by given its distribution on border of the subregions. The equations of T0 method have been given. In the order to solve the equations of T0 method the singular formulation has been employed. The usefulness of the proposed way of winding representation has been tested in the example of the coil of double layer winding of high-voltage induction machine working in cryogenic temperature.
EN
This paper presents an outer rotor in-wheel switched reluctance motor, designed for a cart type electric vehicle. Both of the short and fully pitched winding configurations are developed and analyzed considering the requirements of such a vehicle propulsion motor. Torque profiles and ripple ratios, which are the most important parameters of in-wheel applications are compared for various loading conditions. It is observed that with fully pitched configuration, torque output is increased. However, increasing ripple ratio makes this winding configuration inconvenient for in-wheel propulsion applications, unless any ripple control algorithm is applied.
PL
W artykule zaprezentowano przełączalny silnik reluktancyjny zaprojektowany do pojazdów elektrycznych. Zaprojektowano odpowiednią konfigurację uzwojeń uwzględniając wymagania pojazdu. Głównym wymaganiem był moment napędowy i pulsacje momentu.
EN
Thermal conductivity of windings insulation has significant influence on temperature distribution in power transformer. It means that the conductivity has the influence on aging process of transformer insulation and acceptable load of transformer. Feedback is between temperature and thermal conductivity. So, the solution, obtained using iteration method, should be used, in order to determine temperature distribution in power transformer in details. The paper presents the influence of temperature on thermal conductivity of windings insulation of power transformer and iteration solution of relationship between the conductivity and temperature.
PL
W artykule pokazano wpływ zmian sposobu łączenia uzwojeń pasm przełączalnego silnika reluktancyjnego, na jego moment elektromagnetyczny. Do zasilania silnika zastosowano nowy układ, umożliwiający zmianę konfiguracji połączeń uzwojeń w trakcie pracy napędu. Do analizy wpływu sposobu łączenia uzwojeń w różnych fazach zasiania silnika na moment elektromagnetyczny, opracowano programy symulacyjne, realizujące różne algorytmy zasilania silnika. Obliczenia wykonano dla silnika dwupasmowego, a ich wyniki porównano z uzyskanymi dla napędu z typowym układem zasilania.
EN
The paper shows the influence of SR Motor winding connection configuration on its electromagnetic torque. A new motor supply system was used, which allows winding connection configuration switching during the motor’s operation. For the purpose of the analysis, a set of simulation applications were developed, which realize various supply algorithms. The calculations were carried out for a two-phase motor and their results were compared with a drive supplied from a typical supply system.
PL
W pracy przedstawiono wpływ transpozycji Roebela przewodów elementarnych na rozkład gęstości prądu w pręcie warstwy dolnej i górnej uzwojenia stojana turbogeneratora Zaprezentowano program komputerowy "Bar" umożliwiający wyznaczenie tego rozkładu dla różnych transpozycji przewodów elementarnych w strefie żłobkowej i obu strefach czołowych. Obliczenia przeprowadzono dla pręta warstwy dolnej i górnej wybranego typu turbogeneratora o mocy 450 MVA napięciu 21 kV i częstotliwości 60 Hz. W modelu obliczeniowym uwzględniono sprzężenia magnetyczne między przewodami elementarnymi w strefie żłobkowej (środowisku ferromagnetycznym) i w strefie czołowej (środowisku niemagnetycznym). Dla pręta warstwy dolnej i górnej leżących w żłobku nr 1 i 9 wykonano obliczenia rozkładu gęstości prądu wzdłuż wysokości pręta dla trzech typów transpozycji Roebela: 0 + 180 + 0, 0 + 360 + 0, 0 + 540 + 0.
EN
The paper presents the influence of Roebel strands transposition on current density distribution as a function of the top and bottom bar of turbogenerator stator winding. Here is presented the computer program "Bar" which makes it possible to calculate this current density for different Roebel strands transposition type within slot and overhang parts. The computations were made for selected turbogenerator, which has power 450 MVA, voltage 21 kV and frequency 60 Hz. The application computational model takes into consideration the strands magnetic coupling within as well as slot part (ferromagnetic environment) and overhang part (non-magnetic environment). The calculation results of the bar current density distribution are presented for three following transposition types: 0 + 180 + 0, 0 + 360 + 0, 0 + 540 + 0. The calculated bars are located in slot number 1 and 9.
18
Content available remote Yarn twisting
EN
The mechanism of twist insertion to the strand during ring spinning has been studied. The twisting of the strand occurs not only due to the rotation of twisting elements, but also due to the winding of yarn on the package. When the yarn is wound on a stationary cop by gripping and winding the yarn by hand, for every coil of yarn wind one turn of twist to the yarn is inserted. But the same yarn is over-end withdrawn from the cop, and all twists inserted during winding are removed during unwinding. Over-end unwinding rotates the yarn in the opposite direction. Since the yarn from the cop is over-end withdrawn during winding, the spindle speed is taken for calculating the twist in the yarn, whereas the flyer speed is taken for calculating twist in the roving due to the parallel unwinding of roving during spinning.
19
Content available remote Experimental study of mechanical splicing
EN
An experimental design method was used in order to determine the most relevant parameters as well as the crossing effects to be considered in mechanical splicing. This approach was applied in order to establish a statistical model to predict the splicing properties of thick and medium cotton yarns for denim fabrics. This model shows that the change in the value of drafting has no influence on the properties of the mechanical splicing. Moreover, high values of untwisting and low re-twisting values improve those properties. The result proved that in optimal conditions, and in contrast to pneumatic splicing, the yarn linear density has no influence on the properties of splice. Therefore, mechanical splicing may be used for a wide range of yarns.
20
Content available remote Modernizacja uzwojeń wsypywanych silników asynchronicznych podczas remontów
EN
This article deals with the interrelationship of performance characteristics of the induction motors with the fillings windings that are dependent on the type of windings which are used during the repair. In order to decrease the labor-intensiveness of the technological process one could make wider use of a lathe for the mechanized working of this kind of motors. At the same time it could cause an increase in the losses in the magnetic wires, the size of power loss, the decreasing of its reliability, and the term of its operation. This type of motor could be mainly repaired by service station whose technological equipment is different from the equipment of big businesses. A solution for all of these problems could be a process of modernization of the stators' windings during the repair. This modernization includes the replacement of single-layer or single-double-layer concentric windings in favor of single-layer equipment windings or double-layer windings. There are examples of the realization of the different types of windings that could provide the minimization of copper use without increasing the labor-intensiveness of the procedure. At the same time it provides the decrease of power lose in the motors with invariably power factor.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.