The process' characteristics. Wet oxidation vs. burning - similarities and differences. Design solution for sludge treatment using wet oxidation. Energy balance of the process. Basic wet oxidation of sludge with pure oxygen.
EN
A mathematical model enabling a quantitative description of wet oxidation of excess sludge in continuous bubble columns is proposed. The model consists of mass and heat transfer kinetic equations and material and heat balance equations of gas and liquid phases flowing through the absorber. The equations of material and heat balance refer to a parallel, co- current flow of gas and liquid phase and take into account a complex chemical reaction in the liquid phase core. The proposed model was used in a numerical simulation of wet oxidation in a bubble absorber for different process conditions: flow rate and composition of the gas and liquid phase, temperature and pressure, and different heights and diameters of the column.
4
Content available remote The advanced kinetic model of the excess activated sludge wet oxidation
EN
The objectives of the research were to study the mechanism and reaction kinetics of wet air oxidation oft the activated sludge. The effect of temperature, oxygen partial pressure and the concentration of substrates on the reaction rate was measured. On the basis of the experimental data, the scheme of the reaction pathway was discussed and the kinetic model of this process, which consists of the concentration of the solid phase and the rest of the parameters, was proposed. The special techniques of optimization were applied to calculate the kinetic parameters of this model, e.g. activation energy, the prepotential coefficient of the Arrhenius' equation and reaction order.
5
Content available remote Mathematical modelling of wet oxidation of excess sludge in bubble columns
EN
A mathematical model enabling a quantitative description of wet oxidation of excess sludge in continuous bubble columns is proposed. The model consists of mass and heat transfer kinetic equations as well as material and heat balance equations of gas and liquid phases flowing through the absorber. The equations of material and heat balance refer to parallel, the co- and counter-current flow of gas and liquid phase and take a complex chemical reaction in the liquid phase core into account. The proposed model was used in a numerical simulation of wet oxidation in a bubble absorber for different process conditions: the flow rate and the composition of the gas and liquid phase, the temperature and pressure, and different heights and diameters of the column.
PL
Osady ściekowe powstające podczas oczyszczania ścieków w oczyszczalniach biologicznych są bardzo uciążliwe i niebezpieczne. W ciągu kilku lat Polska wejdzie do Unii Europejskiej, dlatego poszukiwanie alternatywnych metod postępowania z osadami ściekowymi innymi niż składowanie jest nieodzowne. Problem ten może zostać rozwiązany dzięki mokremu utlenianiu, które dokonuje konwersji niebezpiecznego i biologicznie niestabilnego medium w ustabilizowany osad, pozbawiony negatywnego wpływu na środowisko. Proces mokrego utleniania prowadzony jest w temperaturach 150¸350°C pod ciśnieniem 1,5¸16,0 MPa i zachodzi dzięki kontaktowi fazy gazowej zawierającej utleniacz (tlen) z zawiesiną osadu czynnego. Podczas procesu związki organiczne z masy reaktywnej zostają utlenione, co prowadzi z kolei do powstania CO2, wody oraz małych ilości niskocząsteczkowych kwasów organicznych. Proces jest prosty technologicznie, jednakże wysoka temperatura i ciśnienie wymuszają surowe wymagania odnośnie do konstrukcji urządzeń, odporności na korozję oraz bezpieczeństwa procesowego. W pracy tej opisana została seria eksperymentów prowadzonych nad mokrym utlenianiem nadmiernego osadu ściekowego z trzech różnych oczyszczalni regionu łódzkiego. Eksperymenty przeprowadzone zostały bez dodatku substancji wspomagających, a także z dodatkiem nadtlenku wodoru. Na podstawie przeprowadzonych badań okazało się, że skuteczność procesu mokrego utleniania nie zależy od pochodzenia osadów, co z kolei świadczy o ich podobnych właściwościach fizykochemicznych. Dlatego też proces mokrego utleniania może być łatwo zastosowany dla osadów czynnych różnego pochodzenia.
EN
Activated sludge formed in all of wastewater treatment plants is very noxious and hazardous. In the next few years Poland is going to join the European Union therefore searching for alternative sludge treatment methods, other than landfill is essential. This problem can be solved by wet oxidation which converts a dangerous and biologically unstable medium into fully stabilized sludge without negative influence on the environment. Wet oxidation is a process conducted at temperature of 150¸350°C, under pressure of 1.5¸16.0 MPa and it proceeds due to contacting a gas phase containing an oxidant (oxygen) with an activated sludge suspension. During the process organic compounds in the reactive mass are oxidized which leads to the formation of CO2, water and small amounts of low-molecular organic acids. The process is simple technologically, however high temperatures and pressures extort stringent requirements so the construction of the equipment, corrosion resistance and process safety are concerned. A series of experiments on wet oxidation process of excess activated sludge from three different waste water treatment plants from Łódź area are described in this paper. Investigation was carried out with and without addition of hydrogen peroxide. On the basis of the experiments it was found that the efficiency of the wet oxidation process is not dependent on the origin of sludge so the physical and chemical parameters are similar. Therefore the process of wet oxidation of activated sludge can be easily applied for sludge from different sources.
PL
Omówiono zagadnienia związane z technologią mokrego utleniania zanieczyszczeń zawartych w ściekach przemysłowych. Mokre utlenianie to heterofazowy proces utleniania związków organicznych i/lub utlenialnych związków nieorganicznych, prowadzony w roztworze wodnym, pod ciśnieniem od 0,5 do 20 MPa, w temperaturze l25-320°C, za pomocą powietrza lub tlenu tłoczonego do środowiska reakcji. Może być z powodzeniem stosowany do oczyszczania ścieków przemysłowych, które są zbyt stężone, ażeby kierować je na oczyszczanie biologiczne lub też zawierają substancje, które niekorzystnie oddziałują na osad czynny. Przedstawiono mechanizm utlenienia związków organicznych w fazie ciekłej, w warunkach podwyższonej temperatury i pod zwiększonym ciśnieniem. Zwrócono uwagę, że :ze względu na wolnorodnikowy charakter tych reakcji jest w zasadzie niemożliwy szczegółowy opis całego łańcucha przekształceń substratów. Z uwagi na specyfikę procesu mokrego utleniania można w takich przypadkach zastosować uproszczone schematy przebiegu reakcji chemicznych, w których opisuje się jedynie te etapy procesu, które kontrolują szybkość całego łańcucha przekształceń. W pracy przedstawiono także skuteczność procesu mokrego utleniania w odniesieniu do wybranych grup zanieczyszczeń organicznych zawartych w oczyszczanych ściekach i omówiono najważniejsze aplikacje przemysłowe tego procesu. Omówiono także niektóre zagadnienia związane z modelowaniem procesu mokrego utleniania i projektowaniem reaktorów do jego prowadzenia. Odgrywa ono w tym przypadku rolę szczególną, gdyż pozwala na ocenę poprawności przyjętych rozwiązań konstrukcyjnych, a uzyskany model matematyczny staje się cennym narzędziem do oceny bezpieczeństwa pracy instalacji oraz sterowania jego działaniem.
EN
The problems concerning the wet oxidation of industrial wastewaters are deseribed. Wet oxidation is a heterogeneouls process, in which the organic and oxidizable inorganic substances are oxidized using air (or oxygen) at temperature from l25.C to 320.C and pressures from 0.5 to 20 MPa. This is an available options for processing the wastewater streams which are too concentrated for biological treatment or contain the recalcitrant pollutants, toxie for activated sludge microorganisms. The mechanism of chemical reactions taking place in the liquid phase at high temperature and pressures is discussed. It is impossible to describe a detailed mechanism of free radical reactions taking place during the wet oxidation of high molecular organic compounds, so the lumped kinetic model, which consists of only the reaction rate controlled processes, can be successfully used in that ease. The paper reviews the efficiency of removing from treated wastewaters the main groups of organic contaminants dissolved in the liquid phase, and describes same industrial applications of wet oxidation processes as well. Attention is paid to the mathematical procedures used for modeling the wet oxidation reactors. This predietive modeling techniques can be used to optimize, control and improve the safety of wet oxidation facilities.
8
Content available remote Badanie mechanizmu mokrego utleniania nadmiernego osadu czynnego
PL
Zaprezentowano wyniki badania procesu termohydrolizy nadmiernego osadu czynnego. Badania prowadzono w zakresie temperatur 50 ÷ 200°C i pod cisnieniem do 4,0 MPa, oceniając wpływ temperatury i stężenia początkowego substratu na szybkość roztwarzania węgla organicznego tworzącego fazę stałą. Stwierdzono, że w temperaturze 200°C ok. 50% węgla organicznego tworzącego fazę stałą prowadzi do roztworu, a szybkość procesu roztwarzania nie zależy od początkowego stężenia osadu.
EN
A series of experiments on thermohydrolysis of excess activated sludge are described in the paper. The rate of sludge digestion at temperature range from 50 to 200°C and under pressure up to 4.0 MPa was investigated. The effect of initial concentration on the rate of activated sludge particle digestion was also studied. On the basis of the investigations it was found that the process temperature growth enhanced the degree of activated sludge conversion which at 200°C reached 50%.
first rewind previous Strona / 1 next fast forward last