Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  uszkodzenia budowli
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
3D scanning is the most modern method of unlimited possibilities based on laser technology. Its main advantage is the speed of obtaining large amounts of data in a very short time, which gives a huge advantage over existing methods of the measuring. Scanning provides opportunities for use in engineering works, geodetic and the inventory of buildings and objects of a high complexity, as well as in studies of damage or deformation of the structure. 3D scanner is a device, which with high accuracy collects data about the shape and texture of the tested object and its surroundings in the form of a point cloud.
PL
Skanowanie 3D jest to najnowocześniejsza metoda o nieograniczonych możliwościach oparta na technologii laserowej. Jej podstawową zaletą jest szybkość pozyskiwania dużej ilości danych w bardzo krótkim czasie, co daje ogromną przewagę nad dotychczasowymi metodami pomiarowymi. Skanowanie daje możliwości wykorzystania w pracach inżynieryjnych, geodezyjnych, przy inwentaryzacji budynków i obiektów o dużym skomplikowaniu (np. zabytkowych), a także w badaniach ich uszkodzeń i odkształceń konstrukcji. Skaner 3D jest to urządzenie, które z dużą dokładnością analizuje w czasie rzeczywistym mierzoną budowlę oraz zbiera dane o kształcie, fakturze oraz teksturze badanego przedmiotu i jego otoczeniu. Prawidłowo przeprowadzone pomiary dają zbiór punktów o znanych współrzędnych X,Y,Z w formie chmury punktów, które można obrabiać, w efekcie czego stworzony zostaje w pełni cyfrowy, trójwymiarowy model obiektu. Często w czasie inwentaryzacji wykonywanej metodami klasycznymi nie ma możliwości, aby zauważyć wszystkie uszkodzenia występujące na badanym obiekcie. Również trudno jest ocenić i zmierzyć np. zniekształcenia elementów konstrukcyjnych. Analiza obrazu uzyskanego z trójwymiarowej chmury punktów, pozwala na zidentyfikowanie ubytków, określenie wielkości pęknięć i innych odkształceń (np. ugięć belek) we wszelkiego rodzaju budynkach i budowlach.
EN
Issues concerning protection of buildings against the impact of underground coal mining pose significant scientific and engineering challenges. In Poland, where mining is a potent and prominent industry assuring domestic energy security, regions within reach of mining influences are plenty. Moreover, due to their industrial character they are also densely built-up areas. Because minerals have been extracted on an industrial scale in majority of those areas for many years, the rock mass structure has been significantly disturbed. Hence, exploitation of successive layers of multi-seam deposits might cause considerable damage – both in terms of surface and existing infrastructure networks. In the light of those facts, the means of mining and building prevention have to be improved on a regular basis. Moreover, they have to be underpinned by reliable analyses holistically capturing the comprehensive picture of the mining, geotechnical and constructional situation of structures. Scientific research conducted based on observations and measurements of mining-induced strain in buildings is deployed to do just that. Presented in this paper examples of damage sustained by buildings armed with protection against mining influences give an account of impact the mining exploitation in disturbed rock mass can have. This paper is based on analyses of mining damage to church and Nursing Home owned by Evangelical Augsburg Parish in Bytom–Miechowice. Neighbouring buildings differ in the date they were built, construction, building technology, geometry of the building body and fitted protection against mining damage. Both the buildings, however, have sustained lately significant deformation and damage caused by repeated mining exploitation. Selected damage has been discussed hereunder. The structures have been characterised, their current situation and mining history have been outlined, which have taken their toll on character and magnitude of damage. Description has been supplemented with photographic documentation.
3
Content available remote Trzęsienia ziemi w Polsce w 2004 roku
PL
W 2004 roku na terenie Polski wystąpiły dwa trzęsienia ziemi o magnitudach ok. 5,3 i 4,7 w skali Richtera. W niniejszym artykule opisano zaistniałe zjawiska oraz dokonano oceny ich intensywności i wpływu na obiekty budowlane, podając przykłady charakterystycznych uszkodzeń.
EN
Two earthquakes, with the magnitudes of about 5,3 and 4,7 in the Richter scale took place in Poland in 2004. The description of these seismic events as well as the evaluation of their intensities and influence on structures have been discussed in the present paper.
PL
W referacie przedstawiono uszkodzenia oraz sposób naprawy nadziemnego osadnika Dorra o średnicy 40,85 m na ciecz technologiczną w hucie miedzi. OmOwiono i przeanalizowano podstawowe rodzaje uszkodzeń: destrukcję betonu wywołaną agresywnym środowiskiem, uszkodzenia powierzchniowe konstrukcji wsporczej wywołane działaniem środowiska gazowego oraz pęknięcia naroży ram konstrukcji wsporczej, spowodowane nieprawidłowym ułożeniem zbrojenia na etapie wykonania osadnika. Zwrócono uwagę na konieczność zachowania minimalnych przekrojów elementów nośnych oraz właściwych otulin zbrojenia w środowisku agresywnym.
EN
Failures and repair method of elevated Dorra tank of 40.85 m diameter on technological liquid in copperworks are presented in the paper. Basic types of failures like concrete destruction caused by environmental corrosive aggressiveness and corner frames cracks caused high temperature of liquid not taking into account in calculations and abnormal steel detailing are also described.
PL
W referacie opisano powstałe w ciągu ponad 20-letniej eksploatacji uszkodzenia żelbetowej konstrukcji trzykondygnacyjnego budynku oraz technologię przeprowadzenia prac zabezpieczających i remontowych. Aktualny stan budynku jest awaryjny i obiekt ten wymagał kompleksowego remontu, który będzie uwzględniał nie tylko warunki nośności konstrukcji, ale także zapewni przy danym procesie eksploatacji wymaganą trwałość.
EN
Description of damages of 3-storey reinforced concrete structure of a building which appeared during 20 years of exploitation are presented in this paper with technology of refurbishment and protection works. The building was in failure state and required total refurbishment which should took into account capacity conditions and required durability under existing and planned exploitation conditions.
6
Content available remote Przyczyny uszkodzeń pokryć dachowych
PL
Trwałość powłok dachowych ma swój kres. Niekiedy dachy „uśmierca” celowo człowiek, np. podczas rozbiórki, przebudowy bądź modernizacji budynku i dachu, ale znacznie częściej walczy o przedłużenie im „życia.” Producent stara się tworzyć stosowne materiały o coraz wyższych parametrach, wytrzymalszych na starzenie i niszczący wpływ przyrody.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.