Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  urządzenie przekształtnikowe
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
DC/DC converters are wealthy of nonlinear phenomena that appear when the converter parameters are subject to perturbation or variation. The converter may exhibit bifurcation from behavior to another, quasi periodic and chaotic responses. In such cases, it is difficult and even impossible to analyze, to predict and to control the converter behavior. This paper gives a description of a DC/DC converter and shows their desirable and undesirable behaviors; then a solution, based on type-2 fuzzy logic controller, is proposed to eliminate the undesirable behaviors and to enhance the converter dynamics.
PL
Urządzenia przekształtnikowe, jak wszystkie urządzenia elektryczne, podlegają ocenie zgodności. Kluczem dobrze przeprowadzonego procesu oceny zgodności jest właściwy dobór norm zharmonizowanych z dyrektywami. Ważnym elementem tego procesu jest przeprowadzenie szeregu testów i badań w laboratoriach. Istotne jest stosowanie aktualnych standardów przy domniemaniu zgodności (dotyczy to w szczególności norm zharmonizowanych oraz aktualnych norm metod badawczych i norm zawierających wymagania dla aparatury badawczej stosowanej w laboratoriach). Tylko współpraca z kompetentnymi jednostkami będącymi stroną trzecią zapewnia solidność i wiarygodność wyników przeprowadzonej oceny.
EN
Power electronics converters like all other electrical equipment are a subject to conformity assessment. The key to a well-conducted conformity assessment process is the proper selection of standards that are harmonized with the directives. An important element of this process is the conduction of a series of tests and research in specialized laboratories. It is important to use up-to-date standards with the presumption of conformity (this applies in particular to harmonized standards and current standards, test methods and standards containing the requirements for equipment used in research laboratories). Only cooperation with the competent units that are third party to this process provides the robustness and reliability of the results of the proceeded assessment.
PL
[W ocenie właściwości nowoczesnych urządzeń przekształtnikowych wielkie znaczenie ma stwierdzenie zdolności do niezakłóconej pracy w warunkach, gdy w zasilającej sieci występują zaburzenia polegające na krótkotrwałym zmniejszeniu bądź nawet zaniku napięcia. Dla uniknięcia zakłócenia w pracy zasilanych w takich warunkach urządzeń stosuje się środki zaradcze polegające na magazynowaniu energii elektrycznej w pobliżu chronionego urządzenia czy fragmentu systemu i jej dostarczaniu w razie potrzeby.]
PL
W ostatnich latach obserwuje się istotny wzrost zainteresowania zagadnieniami jakości energii elektryczne. Wynika to z kilku powodów, m. n. z wprowadzania do użytkowania urządzeń wrażliwych na zakłócenia zasilania i z rozwoju urządzeń przekształtnikowych, które takie zakłócenia generują.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.