EN
This paper proposes a system design and control technique for a newly developed brushless and permanent magnetless synchronous generator-based variable-speed wind energy generation system, transferring power to a constant voltage dc grid via a three-level Vienna rectifier (VR). The recently established generator named Brushless Induction excited Synchronous Generator (BINSYG) is a wound field synchronous generator (WFSG), whose excitation is developed by controlling an Induction Machine fitted to the same machine structure and sharing the same magnetic core. A new controller is proposed that ensures the stable operation of BINSYG for a wide variation of shaft speeds. VR achieves sinusoidal input current and can control the power factor at its input, which is particularly suitable for wind energy applications. The top and bottom capacitor voltages of the VR are balanced using redundant switching combinations. The system with its proposed control algorithm is modelled in MATLAB/Simulink for a 5 kW rated BINSYG feeding power to a 750 V dc grid. The steady-state and dynamic state simulation results are presented and the controller performance is verified for a wide range of wind speeds. Further, real-time results using the OPAL-RT testbed are presented for the same system to verify the effectiveness of the overall control strategy.
PL
W jednofazowych systemach DC–AC zapewniających sinusoidalny prąd linii AC występuje zjawisko niezbilansowania mocy chwilowych. Niezbędne jest zatem stosowania w takich przekształtnikach tymczasowych magazynów energii. W literaturze coraz częściej prezentowane są topologie implementujące techniki aktywnego magazynowania energii, co pozwala na minimalizację pojemności kondensatorów pośredniczących (ang. DC-link), a przez to prowadzi równiez˙ do minimalizacji ich energii oraz gabarytów. W artykule zaproponowano jedno z takich rozwiązań. Dodatkowo, prezentowana topologia eliminuje składową zmienną podwójnej częstotliwości w prądzie po stronie DC. Przedstawione zostało działanie układu sterowania oraz zaprezentowano wyniki badań laboratoryjnych.
EN
In a single phase DC–AC systems with sinusiodal current in the utility line the phenomenon of instantaneous power imbalance occurs. Therefore in such converts temporary energy storages are needed. Active energy storage techniques (active power decoupling) which allows to minimize the DC-link capacitor capacitance, energy and therefore dimensions, are becoming more popular. The article proposes one of such solutions. Additionally, proposed topology eliminates double frequency alternating component in the DC side current. The operation principle, control system and the results of laboratory tests are presented.
PL
Występujące w jednofazowych systemach AC–DC zjawisko niezbilansowania mocy chwilowych wymaga stosowania tymczasowych magazynów energii. W spotykanych topologiach oprócz rozwiązań tradycyjnych (pasywnych) coraz częściej pojawiają się rozwiązania polegające na aktywnym magazynowaniu energii, co pozwala na minimalizację pojemności kondensatorów pośredniczących (ang. DC-link). W artykule zaproponowano jedno z takich rozwiązań. Opisano topologię i działanie układu sterowania oraz zaprezentowano wyniki badań laboratoryjnych.
EN
The phenomenon of instantaneous power imbalance occurring in single phase AC–DC systems requires the use of temporary energy storage. Lately, in addition to the traditional solutions, active energy storage techniques (active power decoupling) which allows to minimize the DC-link capacitance are becoming more popular. The article proposes one of such solutions. Describes the operation principle, control system and presents the results of laboratory tests.
4
Content available remote Quasi-Direct PWM AC-AC Converter Solution for AC Drives
EN
The topology of the 37-kW quasi-direct ac-ac converter consists of a three-phase voltage source converter, a small plastic film capacitor and a three-phase voltage inverter. Two control boards, based on the dSMC (digital Smart Motion Controller) digital signal processor, were involved in the ac-ac system driving. They have been synchronizing through a fast serial link communication for real-time load power acquisition. The experimental test has been performed in order to show the ac-ac converter operation at distorted by 10% of 5-th harmonic supply line voltage.
PL
Opisano quasi-bezpośredni 37 kW konwerter AC-AC składający się z trójfazowego źródła napięcia, cienkowartstwowego kondensatora i trójfazowego przekształtnika. Dwa procesory sygnałowe sSMC (digital Smart Motion Controller) włączono w układ sterowania. Ich rolą jest synchronizacja systemu napędu w czasie rzeczywistym. Eksperyment wykazał że jedynym zniekształceniem jest obecność 10% piątej harmonicznej.
PL
W referacie przedstawiono podstawy teoretyczne oraz wyniki badań eksperymentalnych układu do bezdotykowego transferu energii elektrycznej. Układ składa się z prostownika wejściowego, falownika rezonansowego z dołączonym na wyjściu transformatorem o obracającej się części wtórnej oraz prostownika wyjściowego. Pojemności i indukcyjności filtrów dobrano tak, aby prąd zasilający miał kształt sinusoidalny a falownik mógł pracować jako rezonansowy. Tranzystory falownika załączają przy zerowym napięciu i wyłączają przy małej wartości prądu.
EN
The theory and experimental results of the Contactless Energy Transmission (CET) system are presented in this paper. The system comprises of an input rectifier, a series resonant inverter with a rotary transformer connected to his output and an output rectifier. The filter capacities and inductivities are selected in such a manner, that the feeding current has a sinusoidal shape and the inverter could work as resonance one. Transistors in the inverter are in a soft switching mode: ZVS and simultaneously almost ZCS.
6
Content available remote Perfect Harmonic Cancellation Strategy for Three-Phase Four-Wire APF
EN
This paper evaluates the performance of four load compensation strategies for a three-phase four-wire system, namely, the p-q method, id-iq method, unity power factor (UPF) method and the perfect harmonic cancellation (PHC) method. The PHC is found to be the best candidate under distorted and unbalanced grid voltage conditions. Excellent steady-state and dynamic performance is achieved by using the presented PHC scheme. Finally, extensive simulation results are provided for verification.
PL
W artykule oceniono strategię kompensacji składowej biernej w układzie czteroprzewodowym metodą p-q, metodą id-iq, metodą współczynnika mocy UPF i metodą eliminacji harmonicznych PHC. Stwierdzono, że najlepsze wyniki w niezrównoważonej sieci napięciowej daje metoda PHC. Wyniki symulacji potwierdzono eksperymentalnie.