In this paper the authors present the test carried out to obtain the uniform velocity distribution at the outlet cross section of flow fan. In the investigations the inner flat vane mounted inside of the impeller has been applied. For various angular position of the inner vane, one obtained different flow structures as well as different velocity distributions. The analysis of the obtained results is presented in form of graphs shown in 10 figures, juxtaposing flow phenomena with velocity distributions. Numerical flow simulation with the use of Flo++ program based on the Finite Volume Method was carried out.
PL
Niniejsza praca zawiera próbę uzyskania jednorodnego rozkładu prędkości w strefie wylotowej wentylatora poprzecznego za pomocą płaskiej łopatki zamontowanej obrotowo w osi wirnika. Dla różnych położeń kątowych łopatki wewnętrznej alfa otrzymano zróżnicowane struktury przepływu wewnątrz wentylatora oraz różne rozkłady prędkości w przekroju poprzecznym kanału wylotowego, co zaprezentowano na 10 rysunkach. Symulacje numeryczne przepływu przeprowadzono wykorzystując program Flo++ oparty na metodzie objętości skończonych.