Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ultra-high performance liquid chromatography
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Flavonoids are the most abundant components in Salvia plebeia, with significant pharmacological antioxidant and hepatoprotective properties. Hispidulin and homoplantaginin are the main flavonoid components in S. Plebeia. In this study, we established an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to determine hispidulin and homoplantaginin in rat plasma samples, which were precipitated using acetonitrile-methanol (9:1, v/v). We used a UPLC HSS T3 (100 mm × 2.1 mm, 1.7 μm diameter) chromatographic column, an acetonitrile-water (containing 0.1% formic acid) mobile phase, and a gradient elution flow rate of 0.4 mL min⁻¹ in an elution time of 4 min. We used electrospray ionization (ESI) detection in positive ion mode, and multiple reaction monitoring mode (MRM) for quantitative analysis: m/z 301 → 286 for hispidulin, m/z 463 → 301 for homoplantaginin, and m/z 465 → 303 for internal standard (IS). In pharmacokinetic studies, 24 rats were orally administered hispidulin and homoplantaginin (5 mg kg⁻¹) and received sublingual intravenous injections (1 mg kg⁻¹) at two different doses, four groups with six rats/group. Differences in hispidulin and homoplantaginin pharmacokinetics in rat plasma were evaluated. The calibration curve showed good linearity in the 0.5–1,000 ng mL⁻¹ range, with r > 0.99. Precision, accuracy, recovery, matrix effects, and stability results all met standard biological sample detection requirements. Our pharmacokinetic studies showed hispidulin bioavailability was much higher than homoplantaginin at 17.8% and 0.1%, respectively.
EN
This paper develops an instrumental analytical approach for detection of fourteen polycyclic aromatic hydrocarbons (PAHs) in edible oil samples using gel permeation chromatography (GPC) and ultra-high performance liquid chromatography (UHPLC) coupled with diode array detector (DAD), and fluorescence detector (FLD). The GPC was used to remove triglycerides from edible oil samples. The extracted samples were then detected using UHPLC—DAD—FLD. In order to obtain good separation and high reproducibility, the UHPLC—DAD—FLD experimental condition was optimized. The PAHs including three groups of isomeric PAHs can be separated completely in 12 min using BEH Shield RP 18 column with a suitable gradient elution program. The mean recoveries were in the range of 73–110% with an acceptable reproducibility (RSD < 10%, n = 3). During real sample analysis, the method can decrease the chance of false positives with both DAD and FLD being used simultaneously. The results indicate that the approach is simple, easy, and acceptably reproducible, thereby showing great potential as a method for detection of fourteen PAHs contained in edible oil samples.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.