The article addresses the problem of short-circuits in DC circuits of high voltage direct current (HVDC) transmission systems. The current state of HVDC technology development, including achievable parameters of semiconductor components, relevant for short-circuit strength, are presented. The differences between voltage source converter (VSC HVDC) topologies are described from the perspective of affecting the possibilities of switching off short-circuit currents and the results of simulation tests for selected topologies are presented. Responses of a system with a cable and overhead line to ground-fault of one or both poles are analysed and compared. The results of the analysis have shown that short-circuits in the DC circuits of a VSC HVDC system cause a rapid and very significant increase in the short-circuit current, which imposes high requirements on DC breakers that are starting to appear in field applications.
PL
W artykule podjęto problem zwarć w obwodach DC układów przesyłowych prądu stałego na wysokim napięciu (HVDC). Przedstawiono aktualny stan rozwoju technologii HVDC, w tym osiągalne parametry elementów półprzewodnikowych, istotne z punktu widzenia wytrzymałości zwarciowej. Opisano różnice w topologiach przekształtników układów tranzystorowych (VSC HVDC) wpływające na możliwości wyłączania prądów zwarciowych oraz przedstawiono wyniki badań symulacyjnych dla wybra- nych z nich. Poddano analizie i porównano odpowiedzi układu z linią kablową i napowietrzną na zwarcie jednego bieguna lub obu biegunów do ziemi. Wyniki analiz pokazały, że zwarcia w obwodach prądu stałego układu VSC HVDC powodują szybki i bardzo znaczny wzrost prądu zwarciowego, co narzuca duże wymagania na wyłączniki DC, które dopiero zaczynają być w praktyce stosowane.
EN
The paper presents the problem of interaction between an LCC HVDC system and a VSC HVDC system. It was shown that the separate operation of an LCC HVDC system under low short circuit power conditions is possible and that at this level of short circuit power it is possible to transfer the same active power through the VSC HVDC system operating in parallel, under the condition that the inverter of this connection operates in AC voltage regulation mode. On the other hand, in certain circumstances it is this mode that may cause the LCC system operating conditions to worsen, which indicates the need for a careful analysis of such cases in order to properly adjust the settings of the relevant control systems. It has been shown that the settings of the voltage regulation system and the PLL system under normal short circuit power conditions can improve the process of the LCC HVDC system returning to operation post-disturbance, while in the conditions of reduced short circuit power they make this process more difficult.
PL
W artykule przedstawiono problem interakcji pomiędzy układem LCC HVDC a VSC HVDC. Pokazano, że samodzielna praca układu LCC HVDC w warunkach niskiej mocy zwarciowej jest możliwa oraz że przy tym poziomie mocy zwarciowej możliwe jest dodatkowe wyprowadzenie takiej samej mocy czynnej przez równolegle pracujący układ VSC HVDC, pod warunkiem że falownik tego łącza będzie pracował w trybie regulacji napięcia AC. Z drugiej strony w określonych okolicznościach to właśnie ten tryb może być przyczyną pogorszenia warunków pracy układu LCC, co wskazuje na potrzebę dokładnej analizy takich przypadków w celu właściwego doboru nastaw odpowiednich układów regulacji. Pokazano bowiem, że nastawy układu regulacji napięcia i układu PLL w warunkach normalnej mocy zwarciowej potrafią usprawnić proces powrotu do pracy układu LCC HVDC po zakłóceniach, natomiast w warunkach obniżonej mocy zwarciowej ten proces utrudniają.