Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  układ przepływowo-wstrzykowy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Flow-injection spectrophotometric determination of manganese in aqueous solution, using a solid sodium bismuthate reactor has been presented. Manganese (Mn2+) can be determined spectrophotometrically at 308 nm after its on-line oxidation to MnO4- at the room temperature. In acidic media permanganate immediately reacts with sym-diphenylcarbazide to form a complex, the absorbance of which is measured. The linear range of the method was 5 × 10-7 - 1 × 10-4 mol L-1 with a detection limit (3 [sigma]) of 6 × 10-8 mol L-1. The proposed procedure was applied to the determination of Mn2+ in effluents and food, with a relative standard deviation better than 1.85%. The sampling frequency as high as 110 h-1 could be achieved.
PL
Zaproponowano spektrofotometry czną metodę oznaczania manganu w wodnych roztworach w układzie przepływowo-wstrzykowym z zastosowaniem reaktora z bizmutanem sodu. Mangan (Mn2+) oznaczano spektro foto metryczni e po uprzednim utlenieniu on-line, w temperaturze pokojowej, do MnO4(-1). W środowisku kwaśnym nadmanganian natychmiast reaguje z sym-difenylokarbazydem tworząc kompleks, którego absorbancjabyła mierzona. Zakres liniowości metody wynosił 5 x 10(-7)-1 x 10(-4) L(-1), a granica wykrywalności (3Sigma) - 6 x10(-8) mol L(-1). Proponowaną metodę zastosowano do oznaczania Mn(2+) w ściekach i żywności uzyskując względne odchylenie standardowe lepsze niż 1,85%. Częstotliwość próbkowania mogła osiągnąć 110 h(-1).
2
Content available remote Preconcentration of cadmium on different sorbents in flow-injection system
EN
The on-line solid phase extraction of trace amounts of cadmium in flow-injection system was developed. For preconcentration of Cd, cellulose sorbent with phosphonic acid groups Cellex P, chelating resin Chelex 100 and cation exchange resin Dowex 50Wx4 were investigated. The performance of these sorbents in time-based system were compared with regard to detection limit, enrichment factor and interferences from other metal ions. The best dynamic characteristics of retention was observed for functionalized cellulose sorbent Cellex P; an enrichment factor of 260 (for 1 min sample loading) was achieved. The detection limit (3scyma) was 0.7 ug 1(-1) and precision (at 10 ug 1(-1) level) was 5.6% (RSD).
PL
Technikę ekstrakcji do fazy stałej zastosowano do zatężania jonów kadmu w układzie przepływowo-wstrzykowym. Zbadano przydatność celulozowego sorbentu z grupami fosfonowymi Cellex P, chelatującej żywicy Chelex 100 oraz kationowego wymieniacza jonowego Dowex 50Wx4. Porównano zachowanie tych sorbentów pod względem uzyskanej granicy wykrywalności, współczynnika zatężania oraz wpływu innych jonów metali. Najlepsze rezultaty uzyskano dla sorbentu Cellex P; współczynnik zatężania (dla czasu zatężania = 1min) wyniósł 260, granica wykrywalności 0.7 ug 1(-1), a precyzja (na poziomie stężenia 10ug1(-1) Cd) była równa 5.6% RSD.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.