The objective of this study is to assess the threat of contaminating groundwater originating from the first exploitative aquifer level in the municipality of Bodzentyn within the Świętokrzyskie Voivodship. The analysis included 23 representative groundwater intakes from MHP 816 Bodzentyn sheet. The various potential sources of groundwater contamination were identified. The intrinsic vulnerability of the first aquifer to contamination and the water recharge area were determined. In the results intakes potentially threatened by anthropogenic pollution were indicated. Providing information on the potential risks of groundwater contamination will help better plan environmental and decision-making activities in this area. The results can serve as a basis for policy development, land use and sustainable resource management in the municipality of Bodzentyn.
PL
Celem niniejszego opracowania jest ocena zagrożenia zanieczyszczeniem wód podziemnych pochodzących z pierwszego eksploatowanego poziomu wodonośnego w gminie Bodzentyn na terenie województwa świętokrzyskiego. Analizą objęto 23 reprezentatywne ujęcia wód podziemnych z arkusza MHP 816 Bodzentyn. Zidentyfikowano różne potencjalne źródła zanieczyszczenia wód podziemnych. Określono wewnętrzną podatność pierwszego poziomu wodonośnego na zanieczyszczenie oraz obszar zasilania. W wynikach wskazano ujęcia potencjalnie zagrożone zanieczyszczeniami antropogenicznymi. Dostarczenie informacji na temat potencjalnego ryzyka zanieczyszczenia wód podziemnych pomoże lepiej zaplanować działania środowiskowe i decyzyjne na tym obszarze. Wyniki mogą służyć jako podstawa do rozwoju polityki, zagospodarowania przestrzennego i zrównoważonego zarządzania zasobami w gminie Bodzentyn.
EN
The purpose of the article was to estimate the thermal power of groundwater intakes of the Kielce district within the sheets of hydrogeological maps with the serial numbers MHP 813-817, MHP 850-851, and to indicate in this area prospective areas for the development of low-temperature geothermal energy supported by water/water heat pumps. Based on the calculations on the basis of 147 groundwater intakes, it was determined that the estimated values of thermal power resources are in the range of 3.47 kW to 5757.34 kW. The created map of the low-temperature geothermal potential for groundwater intakes indicates the towns of Bodzentyn, Morawica and the villages of Piekoszów, Wolica and the area around the village of Górno as prospective areas.
PL
Poddano analizie elementy systemu hydrodynamicznego: warstwa wodonośna - studnia głębinowa (strefa przyfiltrowa, obsypka żwirowa, filtr) - instalacja do pompowania wody (pompa głębinowa - rurociąg tłoczny) w celu określenia ich parametrów filtracyjnych i hydraulicznych. Oferuje się nowe rozwiązania techniczne mające na celu zmniejszenie strat hydraulicznych i energii układów pompowych pomp głębinowych. Przedstawiono metody diagnozowania stanu technicznego studni głębinowych, nowe filtry pierścieniowe studni, konstrukcji otworów studziennych (z jednej i dwoma kolumnami rur osłonowych), układów pompowych bez rurociągu tłocznego pompy głębinowej oraz technologie regeneracji filtrów i przyfiltrowej strefy studni głębinowych. Przeprowadzono ocenę techniczną i ekonomiczną ich zastosowania na istniejących ujęciach wód podziemnych.
EN
Elements of the hydrodynamic system: aquifer - borehole (filter zone, gravel backfill, well screen) - water pump installation (submersible pump - discharge pipe), were analysed to determine the filtration and hydraulic parameters. New technical solutions to reduce hydraulic losses and energy pumping systems for municipalities were proposed. Methods for diagnosing the technical condition of deep wells, new well screen, well construction (one and two columns of casing pipes) and pumping systems without a submersible pump described. Methods of wells regeneration and deep water filtration zone are given. The technical and economic estimation of their application on the existing water intakes of groundwater is given.
EN
Current administrative and legal rules for obtaining permission for execution of a groundwater intake vary vastly depending on the intended purpose and depth of such an intake. In extreme cases, it might be necessary to prepare a number of reports and assessments, largely overlapping in content, and obtain several administrative decisions. In parallel, Polish geological and mining law allows for execution of a well up to a depth of 30 m and well yield <5m3/d without any permits or formal reports. As a result, investors abuse conditions of "normal use of waters”, and the geological and mining administration lacks any instruments of control in this area. On the backdrop of a presentation of legal requirements related to execution of groundwater intakes in Poland, the author discusses selected legal provisions in force, cross-examining their relevance. The suggestions for changes in procedures and regulations discussed presented in the paper should be considered as a starter for a discussion between hydrogeology experts, geological administration and lawyers.
EN
This article presents research to identify the environmental possibilities of groundwater flow into an intake, excluding the technical aspects of its construction and functioning. The purpose of the study was to set down the so-called water intake potential, which is understood as the highest possible amount of extracted water at the well location, without considering constructional and technological aspects. The research object is a groundwater intake near Świniarsko, used for water supply in Nowy Sącz. A numerical hydrogeological model of the capture area was prepared, which, after calibration, was used for quantitative predictions. The results show that the water exploitation potential (11,130 m3/d) is significantly higher than the current consumption (2,362 m3/d).
PL
Aktualne problemy związane z oceną efektywności inwestycji projektów nowych oraz modernizacji istniejących ujęć wód podziemnych, z uwzględnieniem optymalizacji kosztów. Ocena kosztu cyklu życia jako odpowiednie narzędzie wspomagające wybór najlepszego wariantu w zakresie modernizacji ujęcia. W artykule przedstawiono charakterystykę metodyki LCC (ang. Life Cycle Cost) oraz przykłady jej zastosowania do projektów ujęć wód podziemnych bez skutecznych narzędzi monitorujących procesy jednostkowe w systemie zaopatrzenia w wodę.
EN
The paper is devoted to the current problems of the evaluation of the investment effectiveness at new groundwater intakes and the modernization of existing ones including aspects of the costs optimization. The evaluation of life cycle costs as the adequate tool for assisting in selecting of the best variant or the level of groundwater intake modernization has been shown. The characteristics of LCC methodology and examples of using in projects of groundwater intakes have been presented.
EN
The paper presents the first stage of research on a geostatistical hydrogeochemical 3D model dedicated to the horizontal and vertical spatial and time variation in the topographical, hydrological and quality parameters of underground water in the Kłodzko water intake area. The research covers the period 1977–2012. For this purpose various thematic databases, containing original data on coordinates X, Y (latitude and longitude) and Z (terrain elevation and time – years) and on regionalized variables, i.e., the underground water quality parameters in the Kłodzko water intake area determined for different analytical configurations (22 wells, 14 wells, 14 wells + 3 piezometers), were created. The data were subjected to spatial analyses using statistical methods. The input for the studies was the chemical determination of the quality parameters of underground water samples taken from the wells in the water intake area in different periods of time. Both archival data (acquired in the years 1977–1999, 1977–2011) and the latest data (collected in November 2011 and in January 2012) were analyzed. First, the underground water intake area with 22 wells was investigated. Then in order to assess the current quality of the underground water, 14 wells out of the 22 wells were selected for further chemical analyses and a collection siphon wall was included. Recently, three new piezometers were installed in the water intake area and so new water samples were taken, whereby the databases were supplemented with new chemical determinations. The variation in the topographical parameter (terrain elevation) and in the hydrogeological parameters: water abstraction level Z (with and without the land layout being taken into account) and the depth of occurrence of the water table, was examined. Subsequently, the variation in quality parameters was studied on the basis of data coming from 22 wells, then 14 wells and finally from 14 wells and 3 piezometers. The variation in: Fe, Mn, ammonium ions NH4+, nitrite anion NO3 – and phosphate anion PO4 –3 content values, total organic carbon (TOC) C content, the pH reaction and temperature (°C) of the water was investigated. The basic statistics and distribution histograms of the topographical, hydrogeological and quality parameters (22 wells, 14 wells, 14 wells + 3 piezometers; the years: 1977–1999, 2011, 2011–2012) were estimated and detailed characteristics of the variation in the parameters in the whole underground water intake area over the years were obtained. Generally, the behaviour of the underground water quality parameters has been found to vary in space and time. Thanks to the multidirectional spatial analyses of the variation in the quality parameters in the Kłodzko underground water intake area some regularities in the variation in water quality have been identified.
EN
A six-layer hydrogeological numerical model was constructed in the area of the upper basin of the Bobrza river. The model calculations were conducted by means of a hydrogeological program - Woterloo Hydrogeologic Visual Modflow Pro ver. 4.3.0 WATERLOO HYDROGEOLOGIC, Inc. 180 Columbia St. W. - Unit 1104 Waterlo, Ontario, Canada. A multilayer (3D) model, calculated in the uniform filtration field with the determined flow conditions, was used for the solutions. The objective of the conducted model research was to determine the admissible volume of the extracted groundwater in the municipal capture in Zagnańsk and to present the groundwater circulation system in the area of the conducted model research. The original and the current hydrodynamic fields appearing in the aquifer were reconstructed on the model, and then the balance for the well influence area with determined safe yield was prepared.
PL
W obszarze górnej zlewni Bobrzy wykonany został sześciowarstwowy numeryczny model hydrogeologiczny. Obliczenia modelowe przeprowadzono za pomocą modułu MODFLOW z bloku programowego VISUAL MODFLOW ver. 4.3.0, opracowanego przez WATERLOO HYDROGEOLOGIC, Inc. 180 Columbia St. W. - Unit 1104 Waterlo, Ontario, Canada. Do rozwiązań zastosowano model wielowarstwowy (3D), liczony w jednorodnym polu filtracji, w ustalonych warunkach przepływu. Celem wykonanych badań modelowych było określenie zasobów eksploatacyjnych ujęcia komunalnego w Zagnańsku oraz przedstawienie systemu krążenia wód podziemnych w obszarze prowadzonych prac modelowych. Na modelu numerycznym odtworzone zostało pierwotne i aktualne pole hydrodynamiczne występujące w warstwie wodonośnej, a następnie wykonany został bilans wodny obszaru zasobowego.
PL
W artykule przedstawiono wyniki kompleksowych badań hydrogeologicznych w celu oceny sprawności 40-letnich studni, poprawności wyznaczonych w latach 70. XX w. wielkości zasobów eksploatacyjnych „dużego” ujęcia i zasięgu jego oddziaływania. Badania hydrogeologiczne objęły prace terenowe, kartograficzne, pompowania pomiarowe oraz badania modelowe. Prace terenowe przeprowadzono w trakcie normalnej pracy Zakładu, co wiązało się z szeregiem uciążliwości wynikających z ograniczeń poboru wody dla celów technologicznych. W rezultacie przeprowadzonych badań stwierdzono, iż stan techniczny większości badanych studni, w wyniku 40-letniej eksploatacji, uległ znacznej poprawie, na co wskazuje wyraźny wzrost wydatku jednostkowego nawet o 4,5 raza. Według próbnych pompowań i badań modelowych ujęcie może pracować na poziomie zatwierdzonych zasobów (również pozwoleń wodnoprawnych), jednakże obszar zasilania i oddziaływania jest niemal 2–3 razy większy w stosunku do obszaru oszacowanego metodami analitycznymi zaprezentowanymi w dokumentacji hydrogeologicznej wykonanej w latach 70 ubiegłego wieku.
EN
The paper presents the results of comprehensive hydrogeological studies to evaluate the efficiency of 40-years old wells, correctness of the amount of exploitable groundwater resources of a “large” intake, predicted in the 1970s, and to assess the range of its influence zone. Hydrogeological studies included field work, mapping, test pumping and modelling. Field work was carried out during the normal operation of the Department, which was associated with a number of nuisances resulting from water intake limits for technological purposes. The research found that the technical condition of most wells after 40 years of operation has greatly improved, as indicated by a marked increase in the specific well’s discharge as much as 4.5 times. According to test pumping and modelling studies, the intake can still work at the level of approved groundwater resources (including water-legal permits), however the recharge area and influence zone are almost 2–3 times greater compared to the area estimated by analytical methods presented in the hydrogeological documentation compiled in the 1970s.
PL
Artykuł przedstawia wyniki badań naukowych w celu stworzenia planu modernizacji systemu usuwania żelaza z wód podziemnych na istniejącym ujęciu wód podziemnych w "Jurowcach".
EN
The article presents the results of scientific research in order to create a plan to upgrade the system to remove iron from groundwater at the mouth of the existing groundwater intake in Jurowce.
PL
Przez sufozję rozumiemy wymywanie z podłoża gruntowego najdrobniejszych cząstek gruntu przez strumień wody gruntowej poruszającej się z określoną prędkością. Przemieszczenie ziaren gruntu, będące wynikiem sufozji, powoduje lokalne zwiększenie porowatości, co sprzyja zwiększeniu intensywności filtracji. W artykule podjęto próbę analizy możliwości powstawania zjawiska sufozji na terenie Centralnego Ujęcia Wody w Zawadzie k/Zielonej Góry.
EN
This washing through stream of land water moving with definite speed from lands basis of the smallest particles of soil suffusion. The dislocation of primes grains causes local porosity enlargement. It favours then the enlargement the intensity of filtration. It the test of analysis of possibility formation of phenomenon in article was undertaken was sufozji on terrain of Central Water Intake in Zawada near Zielona Góra.
PL
W artykule przedstawiono analizę warunków hydrogeologicznych, konstrukcję wybranego ujęcia wód podziemnych, stanowiącego otwór studzienny ujmujący czwartorzędowy poziom wodonośny oraz wyniki testu hydrodynamicznego i ich interpretację. Przeprowadzony test polegający na próbnym pompowaniu pomiarowym, umożliwił ocenę zasobów eksploatacyjnych ujęcia. Wielkość obliczonych zasobów eksploatacyjnych ujęcia wody wskazuje, że istnieje możliwość wykorzystania tego ujęcia do zaopatrzenia w wodę dla celów pitnych i sanitarnych z równoczesnym pozyskaniem energii cieplnej z wody podziemnej, za pomocą pompy ciepła.
EN
In the article is presented the analysis of hydrogeological conditions, construction of chosen groundwater capture, which contains an Quarternary water-bearing horizon well and results of hydrodynamical test and its interpretation. This test - pumping test - made an evaluation of admissible volume of extracted groundwater catchment possible. The size of counted admissible volume of water points that there is a possibility of using this groundwater catchment to water supplying for drinking and sanitary purpose, and obtaining of heat energy from groundwater, with the use of a heat pump.
PL
Ze względu na zagrożenie jakości wód podziemnych w Toruniu planowana jest budowa nowego ujęcia Wrzosy III. Dla nowej lokalizacji ujęcia skonstruowano model matematyczny. Obszar badań ma powierzchnię 15 km2. Wody podziemne występują tu w osadach czwartorzędu. Zasilanie wód podziemnych odbywa się głównie na drodze infiltracji opadów (średni moduł zasilania infiltracyjnego wynosi 109,3 mm/rok). Warstwa wodonośna jest również zasilana poprzez dopływ lateralny spoza obszaru badań, od północy z Wysoczyzny Chełmińskiej, oraz poprzez infiltrację z Łysomickiej Strugi. Wydajność eksploatacyjna została oszacowana na około 270 m3/h, przy depresji około 5 m.
EN
The Wrzosy III intake is investigated on account of risk of groundwater quality degradation, to change its location. Therefore, a mathematical model was developed for the new location. The research area covers about 15 km2. Groundwater occurs in the Quaternary formations and the aquifer is recharged mainly by precipitation (infiltration recharge module is 109 mm/year). The rest of the inflow comes from lateral flows from beyond the study area and also to some extent from a river. The safe yield on the new Wrzosy III intake can be estimated at 270 m3/h, with expected drawdowns of about 5 m.