Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  uderzenie pioruna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The electrical network is the set of elements where loads are connected to the generation plants by transmission lines. They can be either overhead or underground cables. A new technology has been introduced to replace these transmission lines with underground cables gas insulated line “GIL”. The latest has many advantages over underground cables and overhead transmission lines, such as low transmission losses, less capacitive load, reliability, personal safety, same operation as overhead lines and negligible electrical aging. GIL can handle much more power than overhead lines dueto its large conductive area. GIL is the best for high voltage. In this paper, the simulation of lightning strike effects on a 400 kV hybrid transmission line located in the Wilaya of Setif in northern Algeria is presented in the absence and presence of line arresters and GIL arresters. The results of this paper can provide a rich and valuable theoretical reference for GIL simulation modeling and evaluation of lightning strike impact on hybrid overhead –GILlines.
PL
Sieć elektryczna to zbiór elementów, w których obciążenia są połączone z elektrowniami za pomocą linii przesyłowych. Mogą to być linienapowietrzne lub podziemne. Nowa technologia została wprowadzona w celu zastąpienia tych linii przesyłowych podziemnymi kablami w izolacji gazowej "GIL". Najnowsza technologia ma wiele zalet w porównaniu z kablami podziemnymi i napowietrznymi liniami przesyłowymi, takich jak niskie straty przesyłowe, mniejsze obciążenie pojemnościowe, niezawodność, bezpieczeństwo obsługi, takie samo działanie jak w przypadku linii napowietrznychi znikome starzenie elektryczne. GIL może obsługiwać znacznie większą moc niż linie napowietrzne ze względu na dużą powierzchnię przewodzącą.GIL jest najlepszy dla wysokich napięć. W niniejszym artykule przedstawiono symulację skutków uderzenia pioruna w hybrydową linię przesyłową400 kV zlokalizowaną w Wilaya,Setif w północnej Algierii w przypadku braku i obecności ograniczników liniowych i ograniczników GIL. Wynikitego artykułu mogą stanowić bogate i cenne teoretyczne odniesienie do modelowania symulacji GIL i oceny wpływu uderzenia pioruna na hybrydowelinie napowietrzne –GIL.
EN
Overhead transmission lines are often the site of direct or indirect lightning strikes, the protection by reliable and sensitive elements to these waves is indispensable in the reversal of these lines. In this paper the protection by lightning arresters based on Zink Metal Oxide has been studied, the ATPdraw software (Alternative Transient Program) has been used to simulate the overhead transmission lines, towers , voltage sources and protection elements. A succession of three lightning strikes has been applied to the 220KV line of El Hassi line located in the north east of Algeria in the wilaya of Setif, the results have been presented and discussed.
PL
Napowietrzne linie przesyłowe są często miejscem bezpośrednich lub pośrednich uderzeń piorunów, ochrona przez niezawodne i czułe na te fale elementy jest niezbędna przy odwracaniu tych linii. W niniejszej pracy badano ochronę za pomocą odgromników opartych na tlenku metalu Zink, do symulacji napowietrznych linii przesyłowych, wież, źródeł napięcia i elementów ochrony wykorzystano program ATPdraw (Alternative Transient Program). Trzykrotne uderzenie pioruna zostało zastosowane do linii 220 kV w linii El Hassi zlokalizowanej w północnowschodniej części Algierii, w wilajacie Setif, wyniki zostały przedstawione i omówione.
PL
Przepięcia to trwające ułamki sekund impulsy napięć, tzw. przebiegi nieustalone o amplitudach sięgających kilkudziesięciu kilowoltów. Uszkodzenia instalacji elektrycznych powstają głównie w wyniku pośrednich efektów uderzenia pioruna lub/oraz przepięć spowodowanych przez procesy łączeniowe odbiorników o dużej mocy.
RU
В статье описаны способы обеспечения электромагнитной совместимости при ударах молнии в молниеотводы подстанции. Предложена новая конструкция двухуровневого заземляющего устройства, обеспечивающая минимизацию напряжения кондуктивных помех на портах микропроцессорного оборудования при ударах молнии
PL
Artykuł opisuje sposoby zapewnienia kompatybilności elektromagnetycznej podczas uderzeń pioruna w piorunochrony podstacji. Przedstawiona jest nowa konstrukcja dwupoziomowego uziemienia, która minimalizuje napięcie zakłóceń przewodowych na portach sprzętu mikroprocesorowego podczas wyładowań atmosfe-rycznych (uderzeń pioruna).
EN
The phenomenon of a lightning strike occurring during aircraft operation may seriously affect the integrity of its components due to the electrically insulating properties of polymers and polymeric composites used for manufacturing the fuselage elements of an aircraft. Due to the very high magnitude of temperature fields appearing during lightning strikes, decomposition and vaporization of the matrix and reinforcement materials occur. This results in a pyrolysis reaction and leads to rapid degradation of polymeric composites. One of the ways to limit such degradation is to make the matrix electrically conducting. Such a material is currently being developed by the authors’ team. In order to perform preliminary evaluation of the ability of the new material to minimize temperature magnitude and degradation during a lightning strike, a comparative study with a carbon fiber-reinforced polymeric composite, typical for aircraft applications, was performed. The comparative analysis was performed based on the coupled thermal-electrical analytical model of the considered composites subjected to a lightning strike. The obtained results show that the developed material, due to its electrical conductivity, receives much less thermal energy during a lightning strike and thus, minimizes degradation processes.
PL
Zjawisko uderzenia pioruna występujące podczas eksploatacji statków powietrznych może istotnie wpływać na integralność ich elementów ze względu na właściwości elektrycznej izolacji polimerów i kompozytów polimerowych stosowanych przy wytwarzaniu elementów kadłubów samolotów. Ze względu na bardzo wysokie wartości pól temperatury powstających podczas uderzeń piorunów zachodzi dekompozycja i odparowywanie materiałów osnowy i wzmocnienia. Powoduje to reakcję pirolizy i prowadzi do szybkiej degradacji kompozytów polimerowych. Jednym ze sposobów ograniczenia takiej degradacji jest wykorzystanie osnowy polimerowej zdolnej do przewodzenia prądu. Taki materiał jest obecnie opracowywany przez zespół autorów. W celu dokonania wstępnej oceny zdolności nowego materiału do minimalizacji wartości temperatury i degradacji podczas uderzenia pioruna przeprowadzono badania porównawcze z kompozytem polimerowym umacnianym włóknem węglowym, typowym w zastosowaniach lotniczych. Analiza porównawcza została przeprowadzona w oparciu o sprzężony termoelektryczny model analityczny rozpatrywanych kompozytów poddanych uderzeniu pioruna. Uzyskane wyniki wskazują, że opracowywany materiał, ze względu na swoją przewodność elektryczną, otrzymuje znacznie mniej energii cieplnej podczas uderzenia pioruna, a tym samym minimalizuje procesy degradacji.
PL
Klimat w Polsce zmienia się. Coraz częściej pojawiają się anomalie pogodowe i związane z nimi gwałtowne burze. Zagrożenie stanowi bezpośrednie uderzenie pioruna w budynek lub w związane z nim przyłącza. Niebezpieczne są również przepięcia powodowane uderzeniami pioruna w jego pobliżu.
EN
Tower-surge impedance is one of the most important parameters for evaluating the insulator voltage of transmission towers and line resistance to lightning strokes. Monotubular steel towers are an alternative to the commonly used lattice towers. The article contains the results of a comparative analysis of the surge impedance of monotubular steel towers and lattice towers for overhead 110kV line.
PL
W artykule omówiono zjawisko rozchodzenia się zakłócenia wywołanego przez wyładowanie atmosferyczne (impuls typu surge). Uderzenie pioruna zamodelowano jako impuls prądowy wstrzyknięty do losowo wybranego miejsca linii długiej. Rozwiązanie w dziedzinie czasu uzyskano za pomocą metody FDTD. Zbadano kilka konfiguracji linii długiej: jednorodną i niejednorodną linię jednofazową i jednorodną linię trójfazową.
EN
This paper deals with surge phenomena on transmission lines. The attack of lightning stroke is considered, so the source of surge phenomena is modelled like an injected current wave at random place on the transmission line. The problem is solved in time domain using the FDTD method. Several configurations of transmission line has been investigated in our work - homogeneous and non-homogeneous one-phase line and homogeneous three-phase line.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.