Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  turbo-generator
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote An application of the Pythagorean fuzzy sets in the fault diagnosis
EN
In this paper, a comprehensive review and critical analyses of methods based on the ordinary fuzzy set, Atanassov’s intuitionistic fuzzy set, and its extensions have been conducted to show their limitations and defects. Then, a novel similarity measure based on the generalized score function has been introduced that incorporates the significance (importance) of information, making it more intuitive to compare them. The proposed method is employed for the fault diagnosis of steam turbine generator unit under Pythagorean fuzzy environment. Ten fault types of rotating machines are established as failure patterns in nine different vibration frequency ranges, expressed in terms of Pythagorean fuzzy numbers. The superiority of the proposed method in dealing with uncertain and vague information is shown by comparing it with some existing measures in numerical examples.
PL
W artykule dokonano kompleksowego przeglądu i analiz krytycznych metod opartych na klasycznym zbiorze rozmytym lub intuicjonistycznym zbiorze rozmytym Atanassova i ich rozszerzeniach w celu wykazania ich ograniczeń i wad. Następnie wprowadzono na podstawie miary wiedzy, nową miarę podobieństwa, która uwzględnia znaczenie (ważność) informacji, czyniąc je bardziej intuicyjnymi przy ich porównywaniu. Zaproponowaną metodę weryfikuje się w przypadku diagnozowania uszkodzeń zespołu turbogeneratora w rozmytym środowisku. Dziesięć typów uszkodzeń turbogeneratora jest określanych jako wzorce uszkodzeń wyrażonych za pomocą liczb rozmytych Pitagorasa opisujących ich symptomy w dziewięciu różnych zakresach częstotliwości drgań. Poprzez porównanie z niektórymi istniejącymi miarami w kilku przykładach liczbowych pokazano przewagę proponowanej metody w opisaniu niedokładnych i niepewnych informacji.
EN
The transition of power grids to implement large amounts of nonsynchronous renewables reduces the inertia in the power system. Therefore, the rate of change of fre- quency (ROCOF) after a fault of given energy is higher in low inertia grids than in grids with mainly synchronous machines operating. Standard faults for the design of existing synchronous machines assume fixed frequency grids, in which an electrically close fault happens. It is not tested, if the machines can ride through transient disturbances with high ROCOF. For ROCOF values of up to 1 Hz/s as foreseen for the upcoming grid code of the Republic of Ireland and up to 2 Hz/s for Northern Ireland, a thorough verification, if generators are capable to ride through such events is necessary. For this study, ROCOF frequency traces provided by the transmission system operators (TSOs) of Ireland were first benchmarked with a full-grid model and in a second step impressed on a model of generators connected to the power grid via a step-up transformer to study transient stability and nonlinear response of the generator. This paper focusses on the ability of nine different synchronous machines to stay connected to the transmission system during severe ROCOF events without losing synchronism.
EN
The paper presents the results of basic design methods and justification of the use of existing materials for limit power turbo-generators with different cooling systems. The control methods necessary to assess the material’s technical condition are listed. Mechanical calculations of a 560 MW turbo generator rotor’s stress condition are reported. It has been shown that the rotor can be operated without restrictions throughout its entire operating lifetime.
PL
W artykule przedstawiono wyniki podstawowych metod projektowania i uzasadnienie zastosowania istniejących materiałów do turbogeneratorów granicznej mocy o różnym chłodzeniu. Podano niezbędne metody kontroli do oceny stanu technicznego stosowanego materiału. Wykonano obliczenia mechaniczne naprężeniowego stanu wirnika turbogeneratora o mocy 560 MW. Wykazano możliwość pracy konstrukcji wirnika bez ograniczeń w ciągu całego okresu eksploatacji.
PL
Omówiono przykłady wnioskowania o stanie technicznym wirnikowych maszyn elektrycznych w przypadku wystąpienia drgań spiralnych. Analizy drgań typu APHT NX pozwalają na szybkie postawienie poprawnej diagnozy, co umożliwia skrócenie czasu awaryjnego odstawienia agregatu krytycznego, jeśli jest ono niezbędne. Pokazano przykłady drgań spiralnych dla silnika asynchronicznego napędzającego pompę główną linii przesyłowej ropy oraz generatora 4-biegunowego.
EN
This paper describes examples of inference about rotating electrical machinery technical condition for situations when spiral vibrations happen. Analysis of these vibrations allows quickly formulated diagnosis of root cases of a problem, and if the malfunction results in the shutdown it can reduce the time an asset is out of operation. Examples of problems relating to electric motor driven a main oil line pump and 4-pole generators are discussed.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.