Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  transmission line model
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Przedstawiono metodę szybkiego i dokładnego wyznaczania maksymalnego prądu i napięcia indukowanego w przewodzie elektrycznym leżącym w bezpośredniej bliskości ziemi i oświetlanym impulsem pola elektrycznego o dużym natężeniu. Do analizy wykorzystano model linii transmisyjnej.
EN
The method of fast and accurate determination of the maximum current and voltage induced in an electric wire lying in close proximity to the ground and illuminated by the impulse of an electric field of high intensity is presented. The transmission line model was used for the analysis.
2
Content available Signal propagation in multi-wire cables
EN
The article presents the analysis of the influence of the pulses propagating in the wires of a multi-wire cables. Special attention was drawn to the process of pulses inducing in the wires to which no pulse signal was provided. The pulses interaction occur in those sections of a cable where a change of wave impedance causing a change in the reflectance is present. The pulse interaction changes its shape and amplitude. This pulse interaction can be used to diagnose the technical condition of the electric power and telecommunication cables.
PL
W artykule przedstawiona jest analiza oddziaływania impulsów przemieszczających się w przewodach linii wieloprzewodowych. Zwrócono uwagę na powstawanie impulsów w przewodach, do których nie jest podawany sygnał impulsowy. Oddziaływanie impulsów występuje w miejscach linii, w których jest zmiana impedancji falowej powodująca zmianę współczynników odbicia. Oddziaływanie impulsów powoduje zmianę ich kształtu oraz amplitudy. Zjawisko oddziaływania impulsów można wykorzystać do diagnostyki stanu technicznego linii elektroenergetycznych i telekomunikacyjnych.
EN
Lightning overvoltages occurring in electrical power systems are especially dangerous for devices installed in network. Lightning transients may cause damages of devices installed in power system. Therefore, analysis of lightning overvoltages in electrical power systems is important to ensure reliability of power supply. For this purpose, development of mathematical models is necessary, however mathematical complexity can lead to slightly different results. In this paper, both various overhead transmission lines models as well as exemplary insulation coordination analysis performed in HV power system have been presented. Simulation results performed for various models of overhead lines implemented in EMTP/ATP software have been presented and compared in this paper.
PL
Przepięcia atmosferyczne są szczególnie niebezpiecznie dla urządzeń zainstalowanych w sieciach elektroenergetycznych. Z tego powodu, zdeterminowanie poziomu przewidywanych przepięć atmosferycznych jest istotne z punktu widzenia koordynacji izolacji. Do tego celu, konieczne jest opracowanie modeli matematycznych poszczególnych elementów sieci elektroenergetycznej. Jednakże, w zależności od sposobu modelowania, wyniki symulacji mogą się różnić pomiędzy sobą. Artykuł zawiera zestawienie trzech modeli matematycznych linii przesyłowych, mogących posłużyć do przeprowadzania symulacji przepięć atmosferycznych. W artykule przedstawiono wyniki symulacji przepięć atmosferycznych przeprowadzonych dla przykładowego systemu z wykorzystaniem różnych modeli linii przesyłowych.
EN
This paper deals with frequency-dependent surge arresters models and transmission lines models utilized for insulation coordination studies. Simulations have performed by means of EMTP/ATP software. Various frequency-dependent surge arresters models and transmission lines models have been compared in this article. Simulations of lightning transient in analyzed power system have been performed and results presented in this paper for various surge arrester and overhead line models. Influence of models application during calculations on simulation results has also been analyzed.
PL
Artykuł dotyczy modelowania zmienno-częstotliwościowych modeli ograniczników przepięć oraz modeli linii przesyłowych, stosowanych do obliczeń koordynacji izolacji przy użyciu programu symulacyjnego EMTP/ATP. W niniejszym artykule przedstawiono wyniki symulacji przepięć podczas wyładowań piorunowych w rozpatrywanej sieci elektrycznej. Obliczenia przeprowadzono z wykorzystaniem różnych modeli ograniczników przepięć oraz linii przesyłowych, w celu porównania wpływu zastosowanego modelu ograniczników przepięć i linii przesyłowych, na wyniki symulacji.
5
Content available remote Analiza numeryczna absorberów metamateriałowych dla zakresu terahercowego
PL
Przy użyciu pakietu programów CST Microwave Studio zaprojektowano szereg struktur metamateriałowych realizujących funkcje absorberów terahercowych. Komórka elementarna sieci tych metamateriałów składa się z elementów metalowych położonych na dwóch równoległych powierzchniach, oddzielonych warstwą dielektryka, wykonanych na podłożu z wysokorezystywnego krzemu. Symulacje numeryczne pozwoliły wyznaczyć współczynniki transmisji i odbicia fal elektromagnetycznych na granicy ośrodka metamateriałowego i próżni oraz absorpcję promieniowania terahercowego przez strukturę metamateriałową w funkcji częstotliwości. Analiza numeryczna potwierdziła występowanie silnej, selektywnej absorpcji promieniowania terahercowego przez zaprojektowane metamateriały. Przeprowadzono również analizę oddziaływań fal terahercowych z rozważanymi metamateriałami posługując się modelem linii transmisyjnej.
EN
Using CST Microwave Studio programming package, a series of structures performing the functions of terahertz metamaterial absorbers were designed. A unit cell of such metamaterials consists of two-layer metal structures, separated by a thin layer of dielectric material, deposited on the substrate of high-resistive silicon. The simulations allowed the determination of transmission, reflection and absorption parameters for electromagnetic waves on the boundary between metamaterial medium and vacuum as a function of frequency. Numerical analysis confirmed the presence of a strong, selective absorption of terahertz radiation by designed metamaterials. The analysis of the interaction of terahertz radiation with the considered metamaterials based on the equivalent transmission line model was also done.
6
EN
Purpose: The aim of the paper was to apply a conventional method - “screen printing” using micrometric pastes to improve the quality of forming front side metallization of monocrystalline solar cells. Design/methodology/approach: The topography of co-fired in the infrared belt furnace front contacts were investigated using confocal laser scanning microscope and scanning electron microscope with an energy dispersive X-ray (EDS) spectrometer for microchemical analysis. There were researched both surface topography and cross section of front contacts using SEM microscope. Phase composition analyses of chosen front contacts were done using the XRD method. Front contacts were formed on the surface with different morphology of the solar cells: textured with coated antireflection layer, textured without coated antireflection layer, non-textured with coated antireflection layer, non-textured without coated antireflection layer. The medium size of the pyramids was measured using the atomic force microscope (AFM). Resistance of front electrodes was investigated using Transmission Line Model (TLM). Findings: The high of deposited front metallization has an influence on value obtained from the contact resistance. This high of silver contact depends on: a paste composition, obtained structure after fired into a infrared belt furnace, the quantity and type of creating connections material molecules between themselves and with a silicon substrate. Research limitations/implications: The contact resistance of the screen-printed front metallization depends not only on the paste composition and firing conditions, but is also strongly influenced by the surface morphology of the silicon substrate. Originality/value: This paper investigates the front contact formation using silver pastes about different composition on silicon solar cells in order to decrease contact resistance and increase efficiency in this way.
PL
W pracy przedstawiono wyniki badań metalograficznych i właściwości elektrycznych elektrody przedniej ogniwa fotowoltaicznego wytworzonego metodą konwencjonalną (przez wypalanie w piecu taśmowym) oraz niekonwencjonalną (przez selektywne spiekanie laserowe). Rezystancję elektrody przedniej oraz strefy jej połączenia z podłożem krzemowym wyznaczono metodą linii transmisyjnych.
EN
The paper presented research results of metallographic and electrical properties of front electrode photovoltaic cell manufactured using both the conventional (by cells fired in a belt furnace) and the unconventional (by selective laser sintering) methods. Resistance of front contact and its connection zone with silicon substrate was investigated using Transmission Line Model (TLM).
EN
Purpose: The aim of the paper is to demonstrate a laser method of micro-machining front contacts of monocrystalline solar wafers. This means forming front electrodes in order to decrease their resistance. It was demonstrated, that laser processing is a promising technique for selective laser sintering (SLS) solar cell contacts compared conventional forming front grid methods. Design/methodology/approach: The topography of laser micro-machining contact formations and screen-printing were investigated using ZEISS SUPRA 25 scanning electron microscope. The materials used in the present invention are different granulation silver powders. The grain size analysis were used in order to determine their size. The transmission line model (TLM) patterns were fabricated by selective laser sintering. Findings: This work presents an initial analysis of a new selective laser sintering/melting process to contact crystalline silicon solar cells. The seed layer was created using both silver pastes and powders by a selective laser sintering, do not use up to now in Poland. These contact structures were investigated microscopically to gain a better understanding of the method and select laser micro-machining parameters, which will influence on electrical parameters of formed front side grids. Practical implications: SLS can produce parts from a relatively wide range of commercially available powder materials. The physical process can be full melting, partial melting, or liquid-phase sintering and depending on the material. The thickness of silicon solar wafer can cause some difficulties connected with adhesion electrode during contact formation process. Originality/value: In pursuing the purpose of increasing the efficiency ç of industrial crystalline solar cells to reduce costs of PV electricity, a measure to improve the front side grid is interesting – decreasing contact resistance and increasing efficiency in this way.
EN
Purpose: The aim of the paper is to analyze how to improve the quality of the screen printed contacts of silicon solar cells. This means forming front side grid in order to decrease contact resistance. Design/methodology/approach: The topography of screen printed contacts were investigated using ZEISS SUPRA 25 scanning electron microscope (SEM) with an energy dispersive X-ray (EDS) spectrometer for microchemical analysis. Front collection grid was created using two types of Ag pastes.The Transmission Line Model (TLM) patterns were fabricated by screen printing method on p – type Czochralski silicon Cz-Si wafer with n+ emitter without texture and with a titanium oxide (TiOx) layer as an antireflection coating (ARC). Electrical properties of contacts were investigated using TLM. Findings: This work presents a conventional analysis of a screen printing process for contact formation in the crystalline silicon solar cells. The seed layer was created using silver pasts by the screen printed metallization. These contact structures were investigated using SEM to gain a better understanding of the obtained electrical parameters. Research limitations/implications: The contact resistance of the screen-printed metallization depends not only on the kind of applied paste and firing conditions, but is also strongly influenced by the surface morphology of the silicon substrate. Practical implications: Contact formation is an important production step to be optimized in the development of high efficiency solar cells. Originality/value: The effect of co-firing different pasts (especially a past, which was prepared using silver nano-powder) on electrical properties of silicon wafers.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.