EN
The aim of the paper is to verify the effectiveness of the new technique of measuring the superheated steam temperature in the transient state in a power plant. It based on the application of a new design thermometer with calculation method using the solution of the inverse heat conduction problem. Steam temperature was also measured with an existing conventional thermometer so that the advantages of the new measurement technique could be assessed. Temperature measurements using both thermometers were made at the boiler start-up, boiler shut-off and during boiler operation. The thermometers were located downstream of the second superheater attemperator. The results of measurements were compared. The fastest change in steam temperature occurred after the sudden injection of water into the attemperator header. In this case, the temperature measurement errors with the conventional thermometer are the highest. Dynamic errors of steam temperature measurement using conventional thermometers exceeded 80 K. The measurements made show a much greater accuracy of the measurement of the transient steam temperature using the proposed new technique.
PL
Celem pracy jest weryfikacja skuteczności nowej techniki pomiaru nieustalonej temperatury pary przegrzanej w elektrowni. Opiera się ona na zastosowaniu termometru o nowej konstrukcji z metodą obliczeniową wykorzystującą rozwiązanie odwrotnego zagadnienia przewodzenia ciepła. Aby możliwe było oszacowanie zalet nowej techniki pomiarowej, wykonywany był również pomiar temperatury za pomocą istniejącego, konwencjonalnego termometru. Pomiary temperatury przy użyciu obu termometrów zostały wykonane podczas rozruchu, wyłączania z ruchu oraz pracy ciągłej kotła. Termometry zostały zamontowane za schładzaczem wtryskowym wtórnego przegrzewacza pary. Wyniki pomiarów zostały porównane. Najszybsze zmiany temperatury pary występują po nagłym wtrysku wody w komorze schładzacza. W tym przypadku błędy pomiaru temperatury za pomocą konwencjonalnego termometru są najwyższe. Błędy dynamiczne pomiaru temperatury pary przy wykorzystaniu konwencjonalnego termometru przekraczają 80 K. Przeprowadzone pomiary wskazują na znacznie większą dokładność pomiaru nieustalonej temperatury za pomocą nowej techniki pomiarowej.
EN
In steady-state conditions when the fluid temperature is constant, there is no damping and time lag so the temperature measurement can be performed with a high accuracy. But when the fluid temperature is varying rapidly as during the start-up, quite appreciable differences occur between the exact and measured temperature because of the time required for the transfer of heat to the thermocouple placed inside a thermometer pocket. The temperature of the fluid is one of the key parameters affecting the proper operation of thermodynamic cycles, so the precise determination of its value is very important. The speed of the response of control systems to a temperature change is closely related to the time constant of the used thermocouples. The paper presents a significant impact of fluid velocity changes (in this case air) on the value of time constants of thermometers. For this purpose, the experimental study was carried out using sheathed thermometers with different diameters and hot junctions. The time constants determined for various thermometers are compared.
PL
Przedstawiono dwa sposoby wyznaczania nieustalonej temperatury czynnika. Obydwa nadają się do zastosowań w trybie on-line dla dowolnych zmian temperatury czynnika w funkcji czasu, w niezmiennych warunkach wymiany ciepła oraz dobrej powtarzalności pomiarów. Po wyznaczeniu stałych czasowych termometrów w funkcji prędkości przepływającego czynnika, zaproponowane sposoby można również zastosować przy zmiennej prędkości i temperaturze przepływającego czynnika, gdy stałe czasowe zmieniają się w czasie pomiaru.
EN
Presented are two methods to determine the transient flowing fluid temperature. Both can be applied for on-line determining fluid temperature changes as a function of time, in steady heat exchange conditions and good measurement repeatability. After determining thermometers’ time constants as a function of fluid velocity, the proposed methods can also be applied in conditions of changing temperature and velocity of the fluid when time constants change during measurement.