Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  transient stability
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The power system is non-linear due to the constant change in loads, generators and operating conditions. In recent years, a substantial quantity of renewable energy sources (RES), has been integrated into the world power grid, which has provided alternatives to fossil fuels, especially since they are economical and environmentally friendly to the environment. But at the level of power system stability many concerns have been raised about its efficiency and its impact on its stability and reliability, so it is essential to investigate this impact. The simulation results demonstrated that the stability of the system is affected by this integration, particularly when conventional production plants predominate in the system.
PL
System elektroenergetyczny jest nieliniowy ze względu na ciągłe zmiany obciążeń, generatorów i warunków pracy. W ostatnich latach znaczna ilość odnawialnych źródeł energii (OZE) została włączona do światowej sieci elektroenergetycznej, co stanowi alternatywę dla paliw kopalnych, zwłaszcza że są one ekonomiczne i przyjazne dla środowiska. Jednak na poziomie stabilności systemu elektroenergetycznego zgłoszono wiele obaw dotyczących jego wydajności i wpływu na jego stabilność i niezawodność, dlatego konieczne jest zbadanie tego wpływu. Wyniki symulacji wykazały, że integracja ta ma wpływ na stabilność systemu, zwłaszcza gdy w systemie dominują konwencjonalne zakłady produkcyjne.
EN
The increase of environmental pollution and the decreasing of the energy is extremely related to social progress. The resolution of the environment pollution depends on renewable energy such as wind energy system. Though, that system is required by transient and voltage stability issues with wind energy employing fixed-speed induction generators to be augmented with resistive type superconducting fault current limiter (SFCL) and dynamic compensation devices, such as a Static Synchronous Compensator units (STATCOM). The use of combined model based SFCL and STATCOM for promoting the transient and voltage stability of a multi-machine power system considering the fixed-speed induction generators is the primarily focus of this study. The proposed combined model functions top reserve simultaneously a flexible control of reactive power using STATCOM controller and to reduce fault current using superconducting technology based SFCL. The effectiveness of the proposed combined model is tested on the IEEE11-bus test system applied to the case of three-phase short circuit fault in one transmission line. A simulation results are presented in this document.
PL
Proponowany w artykule połączony model ma najwyższą rezerwę jednocześnie elastyczną kontrolę mocy biernej za pomocą kontrolera STATCOM i redukcję prądu zwarciowego za pomocą SFCL opartej na technologii nadprzewodnictwa. Skuteczność proponowanego modelu łączonego jest testowana na systemie testowym magistrali IEEE11 stosowanym w przypadku zwarcia trójfazowego zwarcia w jednej linii przesyłowej. Wyniki symulacji przedstawiono w tym artykule.
EN
The article discusses the use of a series braking resistor to improve the transient stability of a power system. In the case under consideration, a series braking resistor is used to keep the synchronism of synchronous generators after a three-phase short-circuit in a transmission line nearby of power plant. Braking resistors have recently been increasingly used in power engineering. This focus of this paper is on how the resistor is incorporated into the generator unit and on the generator braking intensity during a fault. Theoretical considerations were confirmed by simulation tests in a test system.
PL
Artykuł dotyczy zastosowania szeregowego rezystora hamującego do poprawy stabilności kątowej przejściowej systemu elektroenergetycznego. W rozpatrywanym przypadku szeregowy rezystor hamujący wykorzystywany jest do ratowania synchronizmu generatorów synchronicznych po wystąpieniu bliskiego elektrowni 3-fazowego zwarcia w linii przesyłowej. W ostatnim okresie można zauważyć wzrost zastosowań rezystorów hamujących w elektroenergetyce. W tym artykule uwaga została skupiona na sposobie włączenia rezystora w układ blokowy generatora oraz na intensywności hamowania generatora w trakcie trwania zwarcia. Rozważania teoretyczne potwierdzono za pomocą badań symulacyjnych dla systemu testowego.
EN
This paper presents the control strategies and digital simulation for the double-fed induction generator (DFIG)-based wind generators for transient stability studies. The wind turbine power tracking characteristics and the power flow mechanism of the DFIG-based wind plant are analyzed. The rotor-side converter (RSC) control, grid-side converter (GSC) control and the pitch angle control scheme are presented based on the phasor model of the DFIG system. The voltage-regulation mode and var-regulation mode are analyzed using control block diagram, and the simulation results of the benchmark system using Matlab/Simulink are presented. The voltage regulation mode and reactive power capabilities are found to be highly effective for low-voltage ride-through (LVRT) capabilities and transient stability enhancement of the DFIG-based wind generators.
PL
W artykule przedstawiono metodę sterowania silnika typu DFIG w zastosowaniu do elektrowni wiatrowej. Analizie poddano charakterystykę turbiny oraz obwodu mocy z maszyną. Zaprezentowano schematy blokowe zastosowanych struktur sterowania. Otrzymane wyniki symulacyjne potwierdziły wysoką skuteczność i stabilność proponowanego algorytmu także przy obniżonym napięciu sieci (LVRT).
EN
This paper is devoted to the study and analysis of a two-machine infinite-bus (TMIB) power system by applying Lyapunov (energy) function based on the variable gradient method. Firstly, the TMIB power system’s energy function is constructed. More, numerical simulation is studied for Lyapunov (energy) function of the TMIB power system. Finally, the simulation results are obtained by using MACSYMA and some useful conclusions are obtained.
PL
Przedstawiono analizę system z dwoma maszynami i nieskończponą szyną przy zastosowaniu funkcji Lapunova w metodzie zmiennego gradientu. Skonstruowany system poddano badaniom symulacyjnym przy wykorzystaniu MACSYMA.
EN
In this paper the transient stability of power system is improved by development of an efficient generator tripping approach. Tripping number of generators is one of the most-used technique at when a serious disturbance lurching the steady sate operation of the power system. Traditional generator tripping techniques suffered from over-tripping generators beyond the stability requirements. The instability in the power system is usually followed by some delay to be detected by the system which has been unclear for traditional tripping approaches, resulting in misscommitment of tripping generators or unnecessary tripping. As a remedy to this, fuzzy system based rotor angle prediction is proposed to study the behavior of the fault before when the instability detected by the system. However, fuzzy system prediction has an impressive performance on nonlinear systems on which the rotor angle attitude is utterly an identical case with nonlinear characteristics. Results obtained by various and practical simulations exhibit that the stability index of the system improved by less number of tripped generators at the proper time. Simulations are conducted by MATLAB and DIgSILENT software on a 9- bus system with 3 generators to demonstrate the promised results.
PL
Przedstawiono metodę poprawy stanów przejściowych i stabilności system energetycznego przez ulepszenie wyzwalanie generatora. Dla poprawy jakości tego załączania zastosowano układ logiki rozmytej bazujący na przewidywaniu kąta wirnika.
EN
In this paper, transient stability of power systems with structure preserving models is considered. A Hamiltonian function which can be regarded as a Lyapunov function for the system is proposed. Based on this, the influence of flux decay dynamics, especially during a fault, on transient stability is analyzed. With the increase of load power, the variation of stability boundary in the rotor angle/Eq plane is shown. The Energy-based excitation control, aiming at injecting additional damping into the post-fault system may reduce the critical clearing time (CCT). This can be demonstrated by the comparison of different flux decay dynamics in the fault-on condition, and the reason is illustrated by the relationship between rotor angle/Eq and the stability boundary. An improved control strategy is proposed and applied to increase the CCT. Simulation results verify that improvement is obtained both in transient stability and dynamic performance.
EN
This paper addresses the state-variable stabilising control of the power system using such series FACTS devices as TCPAR installed in the tie-line connecting control areas in an interconnected power system. This stabilising control is activated in the transient state and is supplementary with respect to the main steady-state control designed for power fl ow regulation. Stabilising control laws, proposed in this paper, have been derived for a linear multi-machine system model using the direct Lyapunov method with the aim of maximising the rate of energy dissipation during power swings and therefore maximising their damping. The proposed control strategy is executed by a multi-loop controller with frequency deviations in all control areas used as the input signals. Validity of the proposed state-variable control has been confi rmed by modal analysis and by computer simulation for a multi-machine test system.
PL
Tematem artykułu jest regulacja stabilizacyjna zmiennych stanu systemu elektroenergetycznego za pomocą urządzeń szeregowych FACTS typu TCPAR, zainstalowanych w liniach międzysystemowych łączących obszary regulacji w połączonym systemie elektroenergetycznym. Taką regulację stabilizacyjną uruchamia się w stanie przejściowym jako uzupełnienie głównej regulacji przepływu mocy w stanie ustalonym. Zaproponowane w niniejszym opracowaniu reguły regulacji stabilizacyjnej wyprowadzono dla liniowego modelu systemu wielomaszynowego, przy użyciu bezpośredniej metody Lapunowa, w celu maksymalizacji rozpraszania energii w trakcie kołysań mocy, a więc ich tłumienia. Proponowaną strategię regulacji wykonuje wielo-wejściowy układ regulacji wykorzystujący odchylenia częstotliwości we wszystkich obszarach regulacji jako sygnały wejściowe. Trafność proponowanej regulacji zmiennych stanu potwierdziła analiza modalna oraz symulacja komputerowa dla testowego systemu wielomaszynowego.
9
Content available remote Use of fuzzy based valve operation for transient stability improvement
EN
This paper proposes a fuzzy based valve to divert the steam to a storage tank during the occurrence of a fault in a power system in order to improve stability of the system. The advantages of this technique over fast valving are discussed. The rate of opening and closing of valve are decided by the fuzzy controller. The valve operation is coordinated with fuzzy based braker. The technique is demonstrated for a single machine infinite bus system.
PL
W artykule zaproponowano zastosowanie sterowania zaworów opartego na technice rozmytej, odwracającego przepływ pary w zbiorniku podczas wystąpienia awarii w systemie elektroenergetycznym, w celu poprawy stabilności systemu. Przedyskutowano zalety tego rozwiązania przy zastosowaniu szybkiej regulacji turbin. O szybkości otwarcia i zamknięcia zaworu decyduje układ regulacji rozmytej. Działanie zaworów jest skoordynowane z hamulcami regulowanymi w technice rozmytej. Technika ta jest przedstawiana w odniesieniu do układu jednomaszynowego.
EN
This paper addresses the state-variable stabilising control of the power system using such series FACTS devices as TCPAR installed in the tie-line connecting control areas in an interconnected power system. This stabilising control is activated in the transient state and is supplementary with respect to the main steady-state control designed for power flow regulation. Stabilising control laws, proposed in this paper, have been derived for a linear multi-machine system model using direct Lyapunov method with the aim to maximise the rate of energy dissipation during power swings and therefore maximisation their damping. The proposed control strategy is executed by a multi-loop controller with frequency deviations in all control areas used as the input signals. Validity of the proposed state-variable control has been confirmed by modal analysis and by computer simulation for a multi-machine test system.
EN
Combinations and Genetic Algorithms for the Locations and tuning of Robust Power System Stabilizers (PSS's) is presented in this paper. The PSS parameters and locations are computed to assure maximum damping performance under different operating conditions. The efficacy of this technique in damping local and inter-area modes of oscillations in multimachine power systems is confirmed through nonlinear simulation results and eigenvalues analysis.
12
EN
The phasor tracking methods enable to identify power angles and rotor speed deviations of the generators. For simplified power system model the power angles and speed deviations constitute the state variables of the system. How to use such state variables to the closed-loop control of the shunt FACTS devices is the subject of the paper. The relevant control formulas are derived for the non-linear system model using direct Lyapunov method. Validity and robustness of the proposed control has been confirmed by simulation for multi-machine test system.
PL
Metoda pomiaru fazorów umożliwia określenie kątów obciążenia generatorów oraz poślizgów ich wirników. W przypadku uproszczonego modelu systemu elektroenergetycznego kąty obciążenia oraz poślizgi wirników stanowią zmienne stanu systemu. Przedmiotem artykułu jest metoda wykorzystania tych zmiennych stanu do sterowania bocznikowych urządzeń FACTS w układzie z zamkniętą pętlą sterowania. Zakłada się przy tym, że obiektem sterowania jest cały system elektroenergetyczny a nie pojedyncze urządzenie FACTS. Odpowiednie wzory określające sterowanie wyprowadzono dla nieliniowego modelu systemu wielomaszynowego korzystając z bezpośredniej metody Lapunowa. Przydatność i poprawność wyprowadzonych wzorów potwierdzono za pomocą symulacji wielomaszynowego systemu z wykorzystaniem proponowanego sterowania.
EN
The paper develops an adaptive fuzzy control system for a turbogenerator. The control system consists of a voltage controller and a power system stabilizer. The parameters of the proposed control system were optimized using genetic algorithms and are updated on line to get an optimum performance of the power system. Simulation tests of the study power system due to three-phase short-circuit or small deviation of the infinite bus voltage is presented. Moreover, a comparison between the power system response using fuzzy control strategy and conventional control is obtained.
PL
W artykule omówiono model rozmytego i adaptacyjnego układu regulacji turbogeneratora. Model ten składa się z: regulatora napięcia i stabilizatora systemowego. Parametry proponowanego modelu układu regulacji zostały zoptymalizowane wykorzystując algorytm genetyczny i są dostrajane w czasie pracy turbozespołu w celu uzyskania optymalnego stanu pracy. Przedstawiono badania symulacyjne przejętego układu jednomaszynowego przy trójfazowym zwarciu i małym zakłóceniu napięcia. Poza tym, porównano wyniki symulacji uzyskane z rozmytym i klasycznym układem regulacji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.