EN
This study complements a series of preliminary experimental studies of the destabilization of a granular stack immersed by fluidization, the particular case being the transient regime of homogeneous fluidization. The significant influence of the initial density (initial volume fraction) of the granular stack on the transient homogeneous fluidization regime is highlighted. An initially loose stack fluidizes turbulently and chaotically in a few seconds, from the injection zone to the top of the granular layer. Conversely, for the same material in an initially dense state, there is a mass takeoff of the stack, which is added to the propagation of porosity wave instability from the bottom to the top of the stack with fast kinetics that decompacts the medium. The results also showed that the velocity of this porosity wave seems almost constant regardless of the fluidization velocity.
2
Content available remote Transient natural convection in partitioned enclosures
EN
In this paper, the natural convection flow in a cavity heated differentially with a partition placed in the middle of the hot wall is numerically simulated. The aspect ratio of the geometry, Prandtl number are fixed at 0.24, 6.64, respectively, for different partitions lengths; however the Rayleigh number values were ranging from 106 to 3:77 x 109 in order to observe the transition regime. The fluid flow and the heat transfer described in terms of continuity, linear momentum and energy equations were predicted by using the finite volume method. To approach the physical reality experience, calculations were performed in a cavity with the same size and same priority of the fluid with an average temperature Tm imposed on the cooled wall, also another simulation with an average temperature Tm imposed on the horizontal wall. Time evolution, isotherms and mean Nusselt number are presented for all investigated values. Representative results illustrating the effects of the partition length for the heat transfer and the thermal boundary layer are also reported and discussed. The results indicate that the flow and heat transfer properties are altered by the presence of the partition, especially in the initial stage. In a certain sense, the partition blocks the flow and forces it to come off the hot wall. Since the partition parameters are critical for the transient natural convection ow in the cavity, different partition lengths on the warm wall have been studied.
3
Content available remote Pompowanie testowe w dokumentowaniu zasobów wód termalnych
PL
W artykule przedstawiono tematykę związaną z wykorzystaniem testów hydrodynamicznych (krótkich pompowań prowadzonych w warunkach dopływu nieustalonego) w procesie dokumentowania zasobów wód termalnych. Omówiono krótko metodykę pompowań testowych, rodzaje testów stosowanych w przypadku wód termalnych oraz najczęściej wykorzystywane metody interpretacji wyników. Zwrócono uwagę na kilka kwestii, które są bardzo ważne na każdym etapie badań, począwszy od zaprojektowania testu, poprzez jego przeprowadzenie, a skończywszy na interpretacji uzyskanych wyników. Szczególny nacisk, zdaniem autorów, należy położyć na zagadnienia związane z właściwym zaplanowaniem i przeprowadzeniem testu oraz użyciem odpowiednich urządzeń i aparatury pomiarowej. Takie podejście gwarantuje uzyskanie wiarygodnych wyników, służących jako podstawa do obliczenia parametrów hydrogeologicznych warstwy wodonośnej. Tylko dysponując wiarygodnymi parametrami będziemy mogli właściwie oszacować wielkość zasobów wód termalnych.
EN
This article presents issues related to the use of hydrodynamic tests (short pumping performed under conditions of transient flow) in the process of documenting the thermal water resources. Briefly discusses the methodology of pumping tests, the types of tests used in thermal waters engineering and the most frequently used methods for results interpretation. Attention was paid to several issues that are important at every stage of research, from designing the test, by its conducting to ending with the interpretation of results. Particular emphasis, according to the authors, should be given to issues related to the proper planning and carrying out the test and use appropriate equipment and apparatus. This approach will guarantee to obtain reliable results, serving as the basis for calculating the hydraulic parameters of the aquifer. Having only reliable parameters, we can correctly estimate the thermal water resources.
PL
Pompowania testowe w warunkach nieustalonego dopływu są nadal rzadko stosowane przy dokumentowaniu zasobów wód podziemnych, zwłaszcza w odniesieniu do wód słodkich (zwykłych). W niniejszej pracy zinterpretowano wyniki testów przeprowadzonych w trzech otworach (A, B i C), charakteryzujących różne warunki hydrogeologiczne. Pompowanie w każdym z otworów miało postać testu wielostopniowego (step test). Interpretacji dokonano przy użyciu programu obliczeniowego AquiferWin32. W pracy poddano analizie prawidłowość doboru schematu i czasu wykonywania testu. W zależności od warunków hydrogeologicznych zastosowano odmienne metody interpretacji. Prawidłowa interpretacja wyników testu hydrodynamicznego zależy w dużej mierze od właściwego zaprojektowania sposobu jego przeprowadzenia. Bardzo ważny jest także dobór odpowiedniej aparatury pomiarowej oraz właściwych urządzeń zapewniających utrzymanie założonego reżimu pompowania. Czynniki te bowiem gwarantują wiarygodność uzyskanych wyników (pomiar depresji przy stałym wydatku). Dopiero rzetelne dane pomiarowe, w połączeniu z właściwie dobraną do warunków hydrogeologicznych metodą interpretacji, pozwolą na obliczenie wiarygodnych parametrów filtracyjnych warstwy wodonośnej.
EN
Test pumpings under conditions of transient flow are still rarely used in documenting groundwater resources, particularly in relation to fresh water. This paper presents interpretation of the results of pumping test conducted in three wells (A, B and C) characterized by different hydrogeological conditions. All of them were multi-step tests. Interpretations were made using the AquiferWin32 software. We examined the correctness of the selection scheme and the timing of the test. Depending on the hydrogeological model, different methods of interpretation were implemented. Correct interpretation of hydrodynamic tests depends largely on the proper design of the test method (pumping scheme). Very important is also the selection of an appropriate measuring apparatus and appropriate devices for securing the assumed pumping regime. These factors ensure the reliability of the results (measured depression at the constant discharge). Only reliable measurement data, in conjunction with a properly matched method of interpretation of the hydrogeological conditions, will allow for reliable calculation of the filter parameters of the aquifer.
5
Content available remote Detection of structural defects in materials through infrared methods
EN
A review of infrared methods used for non-destructive testing of material defects is presented. Some experimental studies with the long wavelength IR camera are carried out when the pulse heating is used. Then the thorough theoretical analysis of the defect detectability with the use of the pulse thermography is performed. A sample with a two-dimensional defect with a rectangular cross-section is considered. Influence of different way of sample heating on thermal contrast is investigated for two materials with widely varying thermal properties.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.