In this paper, the problem related to transformation of ac voltage into DC voltage used in tram supply is considered. A variable component is always present in rectified voltage. Pulsation of rectified voltage is influenced by different factors. In a 12-pulse system, where two secondary transformer windings are used (one delta-connected and the other star-connected), an additional factor increasing the pulsation is the unbalance of the output voltages at these windings. Tap changer may be used and its setting is optimized here by applying the ant-colony algorithm. Different supply voltage variants have been considered. It is demonstrated that pulsation may be reduced by even 25%.
PL
W różnych obwodach elektrycznych wykorzystuje się napięcie stałe powstałe wskutek przetwarzania napięcia sinusoidalnego przemiennego dostarczanego przez sieć elektroenergetycznej. Są to układy różnych mocy, od pojedynczych W do MW. Zachodzi pytanie, jaki układ przetwarzania dobrać jako najefektywniejszy z technicznego i ekonomicznego punktu widzenia. W artykule skupiono się na układach przetwarzania 12- i 24-pulsowych, wykorzystujących wielouzwojeniowe transformatory prostowni-kowe. Przedyskutowano efektywność przetwarzania napięcia przy różnych wariantach napięcia zasilania i podano argumenty przemawiające za ograniczeniem się do przetwarzania 12-pulsowego.
EN
Different electric circuits use dc voltage created by transforming ac sinusoidal voltage supplied by the power grid. These are low- and high-power circuits, with power ranging from single watts to megawatts. The question arises what transforming system should be selected as the most efficient from technical and economical point of view. The authors have focused of 12- and 24-pulse systems utilizing multi-winding rectifier transformers. Effectivess of energy transformation has been discussed depending on the supply voltage variant. Authors have indicated that the 12-pulse system is in their opinion most advantageous.
3
Content available remote Racjonalne przetwarzanie napięcia - czy budować układy 24-pulsowe?
PL
W rożnych układach zasilania, przykładowo w trakcji kolejowej i miejskiej w Polsce, wykorzystuje się napięcie stałe powstałe wskutek przetwarzania napięcia sinusoidalnego przemiennego sieci elektroenergetycznej. Zachodzi pytanie, jaki układ przetwarzania dobrać jako najefektywniejszy z technicznego i ekonomicznego punktu widzenia. W artykule porównano przetwarzania 12- i 24-pulsowe przy rożnych wariantach zasilania oraz podano argumenty przemawiające za ograniczeniem się do przetwarzania 12-pulsowego.
EN
Different supply systems, e.g. railway and city traction in Poland, utilize dc voltage produced by rectification of power grid tree-phase sinusoidal voltage. The question arises, what type of transformation circuit will be most effective from technical and economical point of view. Twelve and twenty-four pulse systems operating under diverse suppply conditions have been compared in the paper. The rationality of applying twelve-pulse system to the exclusion of twenty-four pulse system has been argued.
PL
W artykule zaprezentowano nietypowe zjawiska występujące podczas pracy laboratoryjnego, jednofazowego, wielouzwojeniowego transformatora trakcyjnego. Fenomeny te związane są z występowaniem wady konstrukcyjnej urządzenia, która najprawdopodobniej wynika z zastosowania magnetycznie przewodzących materiałów niektórych elementów konstrukcji wsporczej urządzenia. Jednocześnie nie wyklucza się wykorzystania niskiej jakości impregnatu zlokalizowanego pomiędzy pakietami blachy transformatorowej badanego obiektu. Przedstawiono zmodyfikowany zastępczy schemat transformatora, oparty na klasycznym modelu transformatora dwuuzwojeniowego. Schemat ten pozwala zidentyfikować elementy, dzięki którym praca opisywanego urządzenia może zostać zasymulowana.
EN
The paper shows what problems and different types of phenomena can be found in case when transformers weren't properly constructed. In the article there is presented mono phase, 22 windings, 27 kVa power, traction transformer with construction defect. The defect probably comes from the beams which should support transformers construction, because they are probably made of magnetically conductive materials. The transformers unusual phenomena which come from the defect were shown and described, in addition the cause of the phenomena is explained. In the conclusion modified model of T type equivalent scheme vertical branch, which comes from no load state occurring in the transformer phenomena is shown. The model can be used to create equivalent scheme which might be able to model the transformer later.
EN
It was presented how to design three column substitute diagram of the main magnetic circuit using the impedance matrix of the autotransformer obtained by FEM 3D methods [1, 6, 7]. Relation between main inductances of the magnetic circuit and angular frequency caused by eddy currents in the autotransformer plates was modeled by additional windings on columns short-circuited by admittances. These admittances were synthesized by Cauer ladder schemes. Magnetic saturation of the columns in the substitute diagram should be considered using traditional methods. The substitute diagram presented in this article should be complemented by ladder circuits, which synthesize zero component inductance and leakage inductance [8] of the transformer. Then the diagram can be used for fast calculations of the transient states in clean power multipulse rectifiers circuits. This way of calculations represents proper conditions of the diodes commutation and allows for studying of the circuits higher harmonics.
EN
Commutation processes in power electronic converters are significantly dependent on the leakage inductances of the transformer. The calculations of the leakage inductance matrix where preformed with use of the finite element method (3D). The eddy current losses were taken into consideration. The mono harmonic calculations for different frequencies where performed. The dependence of magnetical inductance main, component zero and leakage were showed from frequency. This caused rotational currents in the core of the autotransformer and in the conductors of windings is. The way of the fusion of these inductances was introduced ladder arrangements. Adaptation of these inductances to the calculations of courses transitory converters district methods was the aim. The article presents ladder circuits, which synthesize zero component inductance and leakage inductance of the transformer. They are also used to complement [8] (remove imperfection) substitute diagram of the main magnetic circuit of the transformer. Including the substitute diagram they can be used for fast calculations of the transient states in clean power multi-pulse rectifiers circuits. This way of calculations represents proper conditions of the diodes commutation and allows for studying of the circuits higher harmonics.