Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  transformata Clarka
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents vector control structures for n-phase AC motors derived from generalized Clarke transformation. In contrast to known works, where authors operate on generalized formulas of the Clarke transformation, in this work, only a number of actually used phases, of mostly industrial purposes, are considered (n = 5, 6, 2×3). This allows to perform control calculations in stationary orthogonal coordinates aβ or rotating dq. There are implementations of different control strategies: ROC (rotor-oriented control) or FOC (field-oriented control). Next, the paper presents the novel concept of a voltage modulator designed for multi-phase drive systems. Operation of the modulator is based on the extended Clarke transformation for multiphase systems. A mathematical model of the multiphase voltage modulator, operating in open-loop and closed-loop current control has been presented. Some selected oscillograms of voltage and current waveform, which illustrate properties of proposed control structures have been presented.
EN
This paper presents accurate fault detection and location using wavelet based on Clarke’s transformation. This study was done using Clarke’s transformation method to convert current phase (three phase) signal into a two-phase current alpha and beta (current mode). The proposed method introduced the mode current to transform the signal using discrete wavelet transform (DWT) and was utilized to obtain the wavelet transform coefficients. Analysis was also conducted for other mother wavelets. The most accurate parent was wavelet Db8, with the fastest time of detection and the smallest error, whereas the largest error was found in Coil4 parent wavelet. The result for proposed method was compared with Db4, Sym4, Coil4 and Db8 and found to be very accurate.
PL
W artykule opisano dokładną metodę wykrywania awarii w sieciach przesyłowych bazująca na falkowej transformacie Clarka. Sygnał trójfazowy jest przekształcany do postaci dwufazowej Za najbardziej się do tego celu nadająca uznano falkę Db8 z najszybszym czasem wykrywania i najlepszą dokładnością. Wyniki porównano z innymi typami falek.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.