Content available Steel telecommunication tower displacement studies
EN
The study of displacements of engineering structures using geodetic methods consists in determining the displacements of the structure in relation to the adopted reference system or in determining the geometry of individual structural elements or the entire structure. The geometry of tower objects is measured cyclically. In the case of telecommunications towers, the most common geometry research is the deviation of the tower axis and the turning angles of the tower at its individual levels. The article presents the methodology and results of the telecommunications tower geometry research obtained for a steel three-legged tower with a height of H = 32.11m. It is a steel tower with a typical structure. The structure in the projection is described on the plan of an equilateral triangle. In the corners of the tower there are curbs in the form of solid round bars. Angular observations were made in two positions of the telescope to selected points on the legs of the tower. The heights of the points on the foundations of the tower were obtained from measurements using the geometric leveling method. The heights of the points at each level of connecting the segments were determined by the trigonometric leveling method based on the measured zenith angles. The measurement points were related to the geometric axes of the tower legs at the connection points of individual segments. The tower displacement parameters were determined from geodetic measurements with the Theo010A theodolite.
2
Content available remote Modele przekrojowe do analizy nośności murowych konstrukcji wieżowych
PL
W artykule przedstawiono modele przekrojowe do analizy nośności murowych konstrukcji wieżowych. Przyjęto nieliniowe związki fizyczne muru ściskanego, z uwzględnieniem efektu jego osłabienia. Wzory określające graniczne bezwymiarowe wartości siły osiowej nmu i momentu zginającego mmu wyprowadzono, całkując równania równowagi sił przekrojowych. Otrzymane rozwiązania odwzorowano w postaci krzywych interakcji nmu – mmu i porównano z rozwiązaniem uzyskanym na podstawie wykresu paraboliczno-prostokątnego.
EN
The paper presents section models for of the resistance of masonry tower structures. Assuming the nonlinear stress-strain relationship for masonry in compression taking into account the effect of its softening. The cross-sectional resistances nmu are derived mmu in the analytical form by integrating the equilibrium equations and taking into account the geometrical and physical relationship. The calculated results are presented in the form of interaction diagrams nmu – mmu and compared with those based on the parabolic-rectangular diagram for masonry in compression.
PL
W niniejszej pracy mowa jest o zapleczu norm kominowych dotyczących wymiarowania trzonu pod względem funkcjonalności, nośności i trwałości jego konstrukcji.
EN
This article concerns the set of standards relating to the dimensioning of chimney shafts in terms of the functionality, load capacity and durability of their structure.
EN
Application of mechanical vibration dampers (MTD) is one of the effective methods of reduction of excessive steel tower structure vibration. Solution of MTD cooperating with high steel chimney was presented. Results of experimental verification of MTD efficiency were presented. The results of measurements obtained in different chimneys were presented.
5
Content available remote Model elementów sprężysto-tłumiących w mechanicznych tłumikach drgań
EN
Elastic-damping elements are the most important parts of a tuned mass damper. Because of these, an accurate description of their behavior is of fundamental importance. In the paper a numerical model for such an element has been proposed. Static and dynamic calculations have been caried out. The results are interesting, however the model needs further development and experimental verification.
6
Content available remote Badania dynamiczne układu budowla wieżowa - mechaniczny tłumik drgań
PL
Jednym ze skutecznych sposobów redukcji nadmiernych drgań stalowych budowli wieżowych jest zastosowanie mechanicznych tłumików drgań (MTD). W [1] przedstawiono rozwiązanie konstrukcyjne MTD współpracującego z wysokim kominem stalowym. Podano tam cząstkowe wyniki doświadczalnej weryfikacji skuteczności MTD. w niniejszej pracy rozszerzono podany w [1] zbiór informacji. Podano wyniki badań uzyskane w kolejnych seriach pomiarowych. Przedstawiono metodykę pomiarową i interpretacyjną, która umożliwia wiarygodną ocenę skuteczności MTD.
EN
Application of mechanical vibration dampers (MTD) is one of the effective methods of reduction of excessive steel tower structure vibration. Solution of MTD cooperating with high steel chimney was presented in [1]. Partial results of experimental verification of MTD efficiency were presented in [1]. The present elaboration is an extension of the set of information. The results obtained in consequent series of measurements were presented. The measurement and interpretation methods permitting evaluation of MTD efficiency were given.