Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  total solar radiation
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
High growth of human population and dynamic socio-economic development have contributed to mounting demand for electric energy. Currently, electric energy is mainly generated from mined and combusted fossil fuels and by the nuclear power plants. The current geopolitical crisis forces mankind to reflect upon the search for alternative energy sources. In this paper analyses of the potential solar radiation volume for 12 months and annual total have been made and visualized on the maps. Additionally, the energy volume gained by the photovoltaic systems in a 12-month period and the annual total as well as underutilised solar radiation energy were calculated. It was found that the tested sites had a solar potential in the range from 113 kWh·m-² to 1314 kWh·m-². For process reasons, only 18 to 203 kWh·m-² could be converted into electric energy, which accounts approximately for 1/5 of the total radiation. The results can be useful to show the best investment site for commercial plants and households in the mountainous area. Surplus energy output should be stored or sold to the power grid. Moreover, the energy source from photovoltaic panels in these areas is only one of the options for green energy generation. investment site for commercial plants and households in the mountainous area. Surplus energy output should be stored or sold to the power grid. Moreover, the energy source from photovoltaic panels in these areas is only one of the options for green energy generation.
PL
W pracy zaprezentowano wpływ zaćmienia słonecznego z dnia 20.03.2015 na zmiany mocy oraz energii elektrycznej produkowanej przez system fotowoltaiczny w porównaniu do bezchmurnego dnia 17.03.2015 oraz do dnia 20.03.2014. System fotowoltaiczny wykorzystuje moduły z krzemu monokrystalicznego oraz inwerter solarny Soladin 600 podłączony do uczelnianej sieci elektrycznej. Moc szczytowa systemu wynosi 330W. Instalacja pracuje w Rzeszowie (φ=50°02’N λ=22°17’E). Moduły fotowoltaiczne zamontowane są na ramie pod stałym kątem 30° względem horyzontu (poziomu). Układ pomiarowy systemu fotowoltaicznego obejmował pomiar napięcia oraz prądu DC przed inwerterem, napięcia, prądu AC, mocy oraz częstotliwości na wyjściu inwertera. Zaprezentowano również pomiary całkowitego i bezpośredniego natężenia promieniowania słonecznego oraz promieniowanie rozproszone w dniu zaćmienia Słońca 20.03.2015 oraz w dniach 17.03.2015 i 20.03.2014 padające na płaszczyznę poziomą. Wszystkie parametry były mierzone co 10 sekund i uśredniane do 1 minutowych wartości. Dokonano również obserwacji wizualnych tarczy Słońca przy wykorzystaniu aparatu fotograficznego DSLR SONY A-57 oraz teleskopu typu Maksutow-Cassegrain o ogniskowej f=1500mm, oraz aperturze 127mm. Światłosiła teleskopu wynosi F 1:11,8. Zestaw zamontowany był na montażu paralaktycznym HEQ-5 SynScan. Wyniki badań ukazują, że podczas maksimum zaćmienia Słońca w Rzeszowie, które wystąpiło o godzinie 10:56 chwilowa moc systemu fotowoltaicznego zmalała o 60%, natomiast dobowa energia elektryczna zmalała o -13,4% w stosunku do niezachmurzonego dnia.
EN
The paper presents the impact of solar eclipse of 20.03.2015 on power and electricity produced changes by the PV system compared to the cloudless day 03.17.2015 and on 20.03.2014. The system uses photovoltaic monocrystalline silicon modules and solar inverter Soladin 600 connected to the electricity grid. Peak power system is 330W. Installation works in Rzeszow (φ = 50°02'N λ = 22°17'E). PV modules are mounted on the frame at a constant angle of 30° relative to the horizon. The measuring system comprised the measurement of voltage and DC current before an inverter, voltage, AC current, power and frequency at the output of the inverter. Also presented measurements of total and direct solar radiation and the scattered radiation in the day of a solar eclipse 03.20.2015 and on 03.17.2015 and 20.03.2014 falling on a horizontal plane. All parameters were measured every 10 seconds and averaged to 1 minute values. Also made visual observations of the sun using a camera Sony DSLR A-57 and Maksutov-Cassegrain telescope with a focal length f = 1500mm, 127mm aperture. Maximum aperture telescope is F 1: 11.8. Set was mounted on an equatorial mount HEQ-5 SynScan. The results show that the maximum eclipse in Rzeszow, which occurred at 10:56 instantaneous power photovoltaic system decreased by 60%, while the daily electricity decreased by -13.4% compared to cloudless day.
EN
This study is based on a 50-year data series (1964-2013) of total solar radiation (G) from the Kołobrzeg – station that is located on the Polish Baltic Sea coast and is characterised by a very high level of air quality. To find and remove gross errors, quality control checking procedures were applied in this study. Additionally, the homogeneity of the G series in this study has been tested on a monthly basis by using of the Standard Normal Homogeneity Test for single shifts. We found a statistically non-significant decrease in G during the period from 1964 to 2013. The decrease in the 5-year mean total solar radiation is evident from the beginning of the 1980s, with the minimum mean value occurring in the second half of the 1990s, while G slightly increased from the early 2000s. The analysis of seasonal G patterns shows that total solar radiation in summer is the most similar to the annual pattern and only the summer series trend shows a statistically significant decrease in G. We have also found two noticeable tendencies in monthly anomalies of G over the studied decades; they are negative trends in May and August. The shape of the decadal daily G histogram remained unchanged during the analysed decades.
4
PL
Celem pracy było określenie wpływu parametrów oszklenia na zużycie energii w wybranej strefie cieplnej. Jako strefę o regulowanej temperaturze wybrano pomieszczenie o charakterze pokoju dziennego z aneksem kuchennym (open space), często spotykane w rozwiązaniach architektonicznych współczesnego budownictwa jednorodzinnego, energooszczędnego. Elewację południową pomieszczenia stanowi przeszklona fasada, która w założeniu miała być elementem pozyskiwania energii cieplnej z promieniowania słonecznego. Wymiary pomieszczenia wynoszą 4,0 x 6,0 m, wysokość 2,8 m. Metoda badawcza przyjęta w pracy to badania numeryczne z wykorzystaniem programów Comfen, Window, Therm oraz EnergyPlus. Do analiz przyjęto 4 warianty. Punkt odniesienia stanowi przeszklona fasada złożona z zestawu szybowego jednokomorowego wypełnionego powietrzem. Pozostałe warianty dobrano tak, aby odpowiadały współczesnym rozwiązaniom zestawów szybowych dla budownictwa niskoenergetycznego. Spełniają one aktualne wymagania izolacyjności termicznej wg [3], przy czym różnią się wartościami współczynników: przenikania ciepła U, całkowitej przepuszczalności energii promieniowania słonecznego g oraz przepuszczalności światła τvis. Są to zestawy trójszybowe, w których komory wypełniono argonem, szyby pokryto powłokami selektywnymi (por. tab. 1). Dodatkowo analizowano wpływ zastosowania ruchomych żaluzji. Najbardziej korzystnymi z punktu widzenia miesięcznych zysków ciepła przez fasadę oraz zużycia energii w roku wydają się być rozwiązania W2 oraz W2_Ż czyli zestaw trójszybowy, w którym komory są wypełnione argonem, szyby pokryte powłokami niskoemisyjnymi, bez lub z żaluzjami.
EN
The goal of this paper was to determine the impact of glazing parameters on energy consumption in selected thermal zone. A room with parameters of a living room and kitchenette was selected as such a zone. Such zones are frequently used in architectural solutions for contemporary energy-saving detached buildings. The south façade is glazed in order to gather thermal energy from solar radiation. The dimensions of this room are as follows: 4.0 x 6.0 m, height of 2.8 m. We chose the numerical method for testing - Comfen, Window, Therm and EnergyPlus software. 4 variants were used in the analysis. The reference point was the glazed façade made of single chamber pane set filled with air. Other variants were selected in such a way that they corresponded to modern solutions of pane sets assigned for low-energy buildings. They meet current requirements of thermal insulating power [3] but they have different values of the following coefficients: heat transfer [U], total permeability of solar radiation energy [g] and light transmittance [τvis]. They are sets with three glasses and chambers filled with argon and the panes are covered with selective coats (see Table 1). Additionally, the impact of movable shutters was tested. From the point of view of monthly heat gains via the façade and annual energy consumption it seems that the most advantageous are W2 and W2_Ż solutions – that is the set with three panes and chambers filled with argon, the panes are covered by low emission coats without or with shutters.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.