Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  total harmonics distortion
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This study aimed at evaluating and analyzing the voltage and current distortions on the introduction of a steel production plant in a typical 33 kV distribution system in Nigeria, with a view to assisting decisions made in the present system operation and planning effective service delivery in terms of quality. A three phase induction furnace was developed using MatLab Simulink software and the effects of steel plant loads on the quality of electric power system supply to electricity users on the same distribution network was analyzed in terms of total harmonic distortions of voltage and current. In order to evaluate voltage magnitude profile on the network, load flow computation and analyses were carried out on the 33 kV distribution network before and after the introduction of steel plant loads, using Successive Approximation Method. The results showed critical voltage magnitude profile below -5% of nominal voltage at the receiving end nodes. With the aid of the Matlab Simulink model, inadmissible voltage and current distortions of 15.47% and 10.35% were measured. Passive filter was proposed, designed and simulated, in order to mitigate these distortions caused by the steel production plant loads. By simulation, the installation of the designed passive filter gave a reduction of the distortions to permissible values. Further, for every 1 MW load increment when the steel plant is connected, network losses increased by 94%; however, for every of Mvar of filter capacity, loss reduction in the network is 5.1 MW.
EN
This study was conducted in order to classify and then to identify the different types of PD based on the characteristic of the harmonic orders. The data from the experimental work has been validated before the harmonic analysis can be commenced. Once the validation stage has been completed, the obtained data is then analysed in terms of its fundamental power frequency and the characteristic associated. The outcome of the analysis shows that each different type of PD produced a distinctive Total Harmonic Distortion (THD) level and distinguishable harmonics order. Based on the findings, a classification has been profiled and a conditional method system is proposed to be used to identify the PD types based on the harmonics order. The outcome of this study shows an accuracy of 98.33% of PD types can be identified from various types of data which have been tested based on the proposed condition.
PL
W artykule przedstawiono wyniki badań dotyczących identyfikacji różnych typów wyładowań niezupełnych w oparciu o analizę harmonicznych. W badaniach wykorzystano wyniki prac eksperymentalnych. Opracowane wyniki wykazały różny wpływ poszczególnych rodzajów wyładowań na współczynnik THD. Na podstawie posiadanych danych możliwa była identyfikacja ponad 98% typów wyładowań.
EN
The paper presents the results of simulation of the power network composed of the main supplying point (PCC) of 15kV, 4km overhead supply line of middle voltage, filter of kth harmonics and 6- and 12-pulse rectifier. In each case we have determined the impedance characteristics of the network as the function of frequency in steady state of AC analysis. The values of the voltage harmonics corresponding to the circuit before and after filter of kth harmonic have been also calculated. The supplying line was simulated by a two-port of the distributed parameters. The numerical data used in experiments have been acquired from the real (physical) power system. All experiments have been performed using Micro-Cap 8 program. In the paper we have included the exemplary results of the numerical calculations.
PL
W artykule przedstawiono wyniki badań symulacyjnych dotyczących współpracy odbiornika nieliniowego 6- i 12-pulsowego prostownika z systemem elektroenergetycznym z dołączonym filtrami wyższych harmonicznych. Dla poszczególnych przypadków przedstawiono zmiany modułów impedancji układu w zależności od częstotliwości wyznaczone przy wykorzystaniu analizy AC. Do obliczeń numerycznych przyjęto dane występujące w układach rzeczywistych a linie zasilające napowietrzne odwzorowano układami o parametrach skupionych . Dla różnych konfiguracji określono wartości wyższych harmonicznych prądu i napięcia oraz współczynniki odkształcenia napięcia i prądu w liniach 15 kV. Wszystkie obliczenia zostały przeprowadzone z wykorzystaniem programu MicroCap-8.
4
Content available remote Estimation of higher voltage and current harmonics generated by the nonlinear load
EN
The results of simulation tests concerning the cooperation of the nonlinear load formed by 6 – pulse rectifier with the power system are presented. In numerical experiments we have taken data from the real systems, including the cable and overhead lines. They have been represented by the distributed parameter system. The values of higher voltage and current harmonics and total harmonic distortion (THD) in 15 kV and 110 kV line, for each considered case have been evaluated by the experiments performed by using the simulation program MicroCap-8.
PL
W artykule przedstawiono wyniki badań symulacyjnych dotyczących współpracy odbiornika nieliniowego (6 – pulsowego prostownika) z systemem elektroenergetycznym. Do obliczeń numerycznych przyjęto dane występujące w układach rzeczywistych a linie zasilające napowietrzne i kablowe odwzorowano układami o parametrach rozłożonych . Dla różnych konfiguracji określono wartości wyższych harmonicznych prądu i napięcia oraz współczynniki odkształcenia napięcia i prądu w liniach 15 kV i 110 kV. Wszystkie obliczenia zostały przeprowadzone z wykorzystaniem programu MicroCap-8 .
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.