Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  total harmonic distortion (THD)
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper describes a Fuzzy Logic approach to Shunt Active power filter (SAPF) versus Hybrid Active Power Filter (HAPF) using Simulink. Here hysteresis controlled PWM method is applied to the SAPF and HAPF as a current controller and Fuzzy logic controller as a inverter dc voltage controller. To reduce harmonics, Shunt Active Power Filters (SAPFs) are used with various control schemes, but Hybrid Active power filter is a power electronic device which has both the characteristics of passive power filters and active power filters, which helps in cancelation of the harmonics by producing compensating signal. The fuzzy-hysteresis controller is designed and its simulation results are presented for both the filter types, showing acceptable THD results for the word length used in the fixed-point computations involved in the switching sequence generation. The results of the above controller are compared with the Indirect current controller.
EN
The article has presented a predictive output voltage regulator of a three-phase two-level voltage inverter with an LC filter with a prediction of the receiver current in the time domain and the frequency domain. Simulations of the operation of the regulator were conducted for a three-phase receiver. The circuit model and simulations of the operation of the predictive voltage regulator were performed in the PSIM program. The algorithm of the predictive regulator was written in the C programming language in the Microsoft Visual Studio compiler and attached to the model performed in the PSIM program by a block that supports the Dynamic-Link Library.
3
Content available remote Design of a passive 48-pulse AC-DC converter for THD stabilization atlLight load
EN
In this paper a 48-pulse uncontrolled AC-DC converter is proposed to mitigate AC line current harmonics of the input side. The proposed rectifier uses conventional 24-pulse parallelly connected rectifier with addition of a passive current injection circuit named as special interphase reactor. The interphase reactor consists of two additional lower rated power diodes. The value of the found THD is 3.55% which satisfies the IEEE 519-1992 standard. Proposed converter also shows lower fluctuation of harmonics valued 1.40% with respect to full load ensuring stable operation at light load. Designed multipulse converter scheme is also simple in construction and requires less number of electronic devices compared to conventional 48-pulse AC-DC converter. This article also explains the simulation and THD performance of the proposed AC-DC converter with proper figure.
PL
W artykule przedstawiono 48-pulsowy przekształtnik AC-DC ze zmniejszoną wartością harmonicznych prądu na wejściu. Proponowany prostownik wykorzystuje 24-pulsowe konwencjonalne prostowniki połączone równolegle z dodatkiem obwodu prądowego nazwanego międzyfazowym reaktorem. Składa się on dwóch dodatkowych diod. Osiągnięto współczynnik THD mniejszy niż 3.55%. Proponowany układ charakteryzuje sie też mniejszą fluktuacja harmonicznych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.