Content available remote Power quality analysis. Case study for induction motor and 110/35kV substation
EN
Power system harmonics have a significant impact on the efficiency, reliability, and stability of the system. Low power quality is determined by undervoltages and overvoltages, dips and swells, blackouts, harmonic distortions, and transients, among other phenomena. ETAP is used to illustrate the specific examples related to these deviations, and the results are graphically displayed. The real induction motor and substation 110/35kV Gjakova 1 within the Kosovo Power System are analysed as a case study. Voltage deviations, load flow, and voltage changes before and after power transformers are analysed.
PL
Harmoniczne systemu elektroenergetycznego mają istotny wpływ na sprawność, niezawodność i stabilność systemu. Niska jakość energii jest określana między innymi przez podnapięcia i przepięcia, spadki i wzrosty napięcia, przerwy w dostawie prądu, zniekształcenia harmoniczne i stany przejściowe. ETAP służy do zilustrowania konkretnych przykładów związanych z tymi odchyleniami, a wyniki są wyświetlane graficznie. Prawdziwy silnik indukcyjny i podstacja 110/35 kV Gjakova 1 w systemie elektroenergetycznym Kosowa są analizowane jako studium przypadku. Analizowane są odchyłki napięcia, przepływ obciążenia i zmiany napięcia przed i za transformatorami mocy.
2
Content available remote Comparison of multilevel inverters with T-type inverter
EN
This paper provides a comparison analysis of various types of multilevel inverters with T-Type inverters. The primary goal of this work is to examine the operation of T-type multilevel inverters with various multilevel inverters. The inverter used in our paper is based on a multilayer bidirectional DC-DC converter that can be used in EV applications. The proposed design incorporates two power switches as well as an additional capacitor to balance the currents of the multilayer T-type (MLI) capacitor over the course of a drive pattern or during fault conditions. Due to the highfrequency cycle-by-cycle current security between CN and CP, the large electrolytic capacitors in T-type MLI have been replaced with longer-lasting film capacitors in this design. Because of this, the dimensions and weight of the converter would be reduced by 20%.
PL
Artykuł zawiera analizę porównawczą różnych typów falowników wielopoziomowych z falownikami typu T. Podstawowym celem tej pracy jest zbadanie pracy falowników wielopoziomowych typu T z różnymi falownikami wielopoziomowymi. Falownik zastosowany w naszym artykule oparty jest na wielowarstwowej dwukierunkowej przetwornicy DC-DC, która może być wykorzystana w aplikacjach EV. Proponowany projekt obejmuje dwa przełączniki zasilania, a także dodatkowy kondensator do równoważenia prądów wielowarstwowego kondensatora typu T (MLI) w trakcie wzorca napędu lub w warunkach awarii. Ze względu na zabezpieczenie prądowe cykl po cyklu o wysokiej częstotliwości między CN i CP, duże kondensatory elektrolityczne w MLI typu T zostały w tym projekcie zastąpione trwalszymi kondensatorami foliowymi. Dzięki temu wymiary i waga konwertera zostałyby zmniejszone o 20%.
EN
The paper presents performance comparison of harmonic filters for the reduction of harmonic distortion in an industrial power system, i.e., National Tobacco Enterprise, an industry found in Ethiopia. The performance comparison is done for single tuned, double tuned, high pass and Ctype harmonic filter. As a result, the double tuned harmonic filter provides a better performance than the other type of filters by giving a reduced Total Harmonic Distortion for the voltage and current waveforms. MATLAB/SIMULINK simulation results are presented for validating the analysis.
PL
W artykule przedstawiono porównanie wydajności filtrów harmonicznych do redukcji zniekształceń harmonicznych w przemysłowym systemie elektroenergetycznym, tj. National Tobacco Enterprise, przemysł znajdujący się w Etiopii. Porównanie wydajności jest dokonywane dla pojedynczego strojonego, podwójnie strojonego, górnoprzepustowego i typu C filtra harmonicznego. W rezultacie podwójnie dostrojony filtr harmonicznych zapewnia lepszą wydajność niż inne typy filtrów, zapewniając zmniejszone całkowite zniekształcenie harmoniczne dla przebiegów napięcia i prądu. Przedstawiono wyniki symulacji MATLAB/SIMULINK w celu weryfikacji analizy.
EN
Cascaded H-Bridge Multilevel Inverter (CH-MLI) is rich in output voltage harmonics. If MLI’s poly-phase output voltage is fed directly as input to drive an induction motor, there is great change in the performance of the motor output. To reduce the lower order harmonics in CH-MLI, a novel selective harmonic elimination method is proposed in this paper. The proposed Cross-Entropy (CE) optimization is implemented to find the optimal switching angle of CH-MLI. The switching angles determined are generated by sinusoidal pulse width modulation in MATLAB based simulation. The performance of CE optimized 11-level CH-MLI connected to an induction motor drive is compared with existing optimization methods. The torque ripple and total harmonics distortion (THD) comparisons are studied. Moreover, Cross-Entropy optimization algorithm simulation results are found superior to the other algorithms in reducing the THD as well as a reduced torque ripple. Using CE optimization technique about 14.45% reduction in torque ripple is attained and 19.14% reduction in THD is found.
PL
Kaskadowy wielopoziomowy falownik H-Bridge (CH-MLI) jest bogaty w harmoniczne napięcia wyjściowego. Jeśli wielofazowe napięcie wyjściowe MLI jest podawane bezpośrednio jako wejście do napędzania silnika indukcyjnego, następuje duża zmiana w wydajności mocy wyjściowej silnika. Aby zredukować harmoniczne niższego rzędu w CH-MLI, w niniejszym artykule zaproponowano nową metodę selektywnej eliminacji harmonicznych. Proponowana optymalizacja entropii krzyżowej (CE) jest wdrażana w celu znalezienia optymalnego kąta przełączania CHMLI. Wyznaczone kąty przełączania są generowane przez sinusoidalną modulację szerokości impulsu w symulacji opartej na MATLAB. Wydajność 11-poziomowego CH-MLI zoptymalizowanego pod kątem CE, podłączonego do napędu silnika indukcyjnego, jest porównywana z istniejącymi metodami optymalizacji. Badane są porównania tętnienia momentu obrotowego i całkowitego zniekształcenia harmonicznego (THD). Co więcej, wyniki symulacji algorytmu optymalizacji krzyżowej entropii okazały się lepsze od innych algorytmów pod względem redukcji THD, a także zmniejszonego tętnienia momentu obrotowego. Przy użyciu techniki optymalizacji CE osiągnięto około 14,45% zmniejszenie tętnienia momentu obrotowego i 19,14% zmniejszenie THD.
EN
The kind of grid-connected loads and the control strategy of harmonic mitigation system using active power filters (APF) play a very important role in terms of total harmonic distortion (THD) and their performances during dynamic operating conditions. Much research deals with these filtering systems only under nonlinear loads with THD values of the source current not exceeding 30%. However when much distorted loads like LED lighting is chosen, the used control strategy can work unsatisfactorily. In this contribution paper, the indirect current control method (ICC) was examined under an extreme case when involving a very high nonlinear load. For the current control, the hysteresis method is adopted which provides switching signals with a fast response and good accuracy. Without require any accurate mathematical model and based on a linguistic description, a fuzzy logic control scheme (FLC) is also developed for the DC-side capacitor voltage to enhance the undesirable dynamic performances obtained using a conventional proportional-integral controller (PI). Simulations outputs and experimental implementation using dSPACE hardware are done under Matlab/Simulink software. Obtained results demonstrate very good performances of the laboratory platform and the control system has been proved to be effective and in perfect compliance with the standard harmonic limits IEEE 519-1992 even when the load current is highly distorted characterized by a high THD more than 60% and an important amplitude of 5th and 7th harmonics.
PL
Rodzaj odbiorników podłączonych do sieci oraz strategia sterowania systemem ograniczania harmonicznych za pomocą filtrów mocy czynnej (APF) odgrywają bardzo ważną rolę w zakresie całkowitego zniekształcenia harmonicznych (THD) i ich wydajności w dynamicznych warunkach pracy. Wiele badań dotyczy tych układów filtrujących tylko przy obciążeniach nieliniowych, przy wartościach THD prądu źródłowego nieprzekraczających 30%. Jednak w przypadku wybrania bardzo zniekształconych obciążeń, takich jak oświetlenie LED, zastosowana strategia sterowania może działać niezadowalająco. W niniejszym artykule, pośrednia metoda sterowania prądem (ICC) została zbadana w skrajnym przypadku, przy bardzo dużym obciążeniu nieliniowym. Do regulacji prądu przyjęto metodę histerezy, która zapewnia sygnały przełączające o szybkiej odpowiedzi i dobrej dokładności. Nie wymagający żadnego dokładnego modelu matematycznego i oparty na opisie językowym, opracowano również schemat sterowania logiki rozmytej (FLC) dla napięcia kondensatora po stronie DC w celu zwiększenia niepożądanych osiągów dynamicznych uzyskanych przy użyciu konwencjonalnego sterownika proporcjonalno-całkującego (PI). Wyniki symulacji i eksperymentalna implementacja przy użyciu sprzętu dSPACE są wykonywane w oprogramowaniu Matlab/Simulink. Uzyskane wyniki wskazują na bardzo dobre osiągi platformy laboratoryjnej, a system sterowania okazał się skuteczny i doskonale zgodny z normami dotyczącymi limitów harmonicznych IEEE 519- 1992, nawet gdy prąd obciążenia jest silnie odkształcony charakteryzujący się wysokim THD powyżej 60% i ważną amplitudę 5. i 7. harmonicznej.
EN
Distributed generation (DG) systems have been widely applied in power systems and will also be the dominant part of future power systems. This type of generation system has features that are distinctive among non-renewable huge capacity fossil and nuclear power generation systems. These types of distributed generation are comparatively very small and most оf them are constructed for the application оf nonconventional energy such as hydraulic power or wind power in the generation of electricity. And, whenever this type of DG system аre functioned in parallel together with main utility power systems, then particularly the power quality problem beсоme more significant with reverse power flow. Reliability, frequency deviation, harmonics, and voltage deviation of the power system are the main power quality problems. Also, a critical, and major problem of power quality is аn islanding protection. Tо resolve islanding problems, the detectors of islanding conditions аre used tо find аn islanded situation and allow the circuit breaker to trip. These circuit breakers are available in between the distributed generation and the power system. This Paper presents а nоvel concept оf the detection of islanding by the support of Slip Mоde Frequency Shift (SMFS) technique fоr the defense оf distributed generator fed systems from the Islanding conditions which has been tested and verified by the help of the proposed Simulink diagram on Matlab-2021a platform.
PL
Systemy generacji rozproszonej (DG) są szeroko stosowane w systemach elektroenergetycznych i będą również dominującą częścią przyszłych systemów elektroenergetycznych. Ten typ ma cechy charakterystyczne dla nieodnawialnych systemów wytwarzania energii z paliw kopalnych i jądrowych o dużej mocy. Różne rodzaje generacji rozproszonej są porównywalnie małej mocy i większość z nich jest konstruowana do wykorzystywania energii niekonwencjonalnej, takiej jak energia hydrauliczna lub energia wiatru do wytwarzania energii elektrycznej. I kiedy ten typ systemu DG działa równolegle z głównymi systemami zasilania, to szczególnie problemy z jakością zasilania stają się bardziej znaczące przy odwróconym przepływie mocy. Niezawodność, odchylenie częstotliwości, harmoniczne i odchylenie napięcia systemu elektroenergetycznego to główne problemy dotyczące jakości energii. Ponadto krytycznym i głównym problemem jakości energii jest ochrona wysp. Aby rozwiązać problemy związane z wyspą, detektory warunków wyspowych są wykorzystywane do wykrycia szczególnej sytuacji na wyspie i umożliwienia przerwania obwodu. Wyłączniki są dostępne pomiędzy generacją rozproszoną a systemem elektroenergetycznym. Niniejsza praca przedstawia nowatorską koncepcję wykrywania zjawisk wyspowych przy pomocy techniki przesunięcia trybu poślizgu częstotliwości (SMFS) do ochrony systemów zasilanych z generatorów rozproszonych przed warunkami wyspowymi. Pomysł został przetestowany i zweryfikowany za pomocą proponowanego diagramu Simulinka na platformie Matlab-2021a.
7
Content available remote A fully-balanced current-tunable all-pass filter with CAPRIO technique
EN
This paper presented the improvement of the first-order all-pass filter fully-balanced current-turnable with the Caprio technique. The proposed circuit was designed with NPN transistors, a capacitor, and a resistor. The amplitude of the signal can have been directly controlled by adding an external resistor (Ree) and has been tuneable electronically. The circuit has a relatively simple architecture. The Caprio technique can reduce total harmonic distortion (THD) to a low level. The proposed circuits were verified by the SPICE simulation, confirming the theoretical analysis.
PL
W artykule przedstawiono udoskonalenie filtra wszechprzepustowego pierwszego rzędu, w pełni zbalansowanego z obrotnicą prądową z wykorzystaniem techniki Caprio. Proponowany układ został zaprojektowany z wykorzystaniem tranzystorów NPN, kondensatora i rezystora. Amplituda sygnału może być bezpośrednio kontrolowana przez dodanie zewnętrznego rezystora (Ree) i jest dostrajana elektronicznie. Układ ma stosunkowo prostą architekturę. Technika Caprio może zredukować całkowite zniekształcenia harmoniczne (THD) do niskiego poziomu. Zaproponowane obwody zweryfikowano symulacją SPICE, potwierdzając analizę teoretyczną.
EN
In order to ensure that all the connected Equipment in the distribution network operates smoothly, the voltage stability of photovoltaic (PV) integrated distribution systems is very important. Sustaining the voltage profile when integrating PV is a particularly difficult issue. The primary goal of this article is to provide a consistent voltage profile to a sensitive load. A three-phase PV integrated distribution system has been chosen for investigation. An innovative feature of this system is that UPQC DVR and STATCOM systems are powered by Z-source inverters instead of traditional inverters. The ability to actively decouple power is the primary benefit of utilizing a Z-source inverter. The objective of the study effort is to use this new UPQC to synchronize a solar PV system with the distribution system. For the UPQC with battery energy storage system (BESS), the research study examines and develops the most appropriate control approach. A UPQC is a device that is used to integrate solar panels and improve the voltage stability of the distribution system. The prototype model is being developed, and the experimental findings confirm the main objective.
EN
The electrical grid integration takes great attention because of the increasing population in the nonlinear load connected to the power distribution system. This manuscript deals with the power quality issues and mitigations associated with the electrical grid. The proposed single comprehensive artificial neural network (SCANN) controller with unified power quality conditioner (UPQC) is modelled in MATLAB Simulink environment. It provides series and shunt compensation that helps mitigate voltage and current distortion at the end of the distribution system. Initially, four proportional integral (PI) controllers are used to control the UPQC. Later the trained SCANN controller replaces four PI Controllers for better control action. PI and SCANN controllers’ simulation results are compared to find the optimal solutions. A prototype model of SCANN controller is constructed and tested. The test results show that the SCANN based UPQC maintains grid voltage and current magnitude within permissible limits under fluctuating conditions.
10
Content available remote PQ & DQ based shunt active power filter with PWM & hysteresis techniques
EN
Power quality is mainly affected by any deviation in voltage, current, or frequency that results in damage, upset, or failure of end-use equipment. Non-linear loads like power electronics devices are the main causes of power quality problems. In this paper, we performed a comparison between DQ and PQ theory to control the shunt active power filter by using hysteresis and PWM techniques at different non-linear loads (controlled and uncontrolled rectifiers) in terms of the amount of improvement in the THD, power quality, and switching losses. The MATLAB / Simulink was used as a simulation tool to obtain a result for this paper.
PL
Na jakość energii wpływają głównie wszelkie odchylenia napięcia, prądu lub częstotliwości, które powodują uszkodzenie, niesprawność lub awarię sprzętu końcowego. Obciążenia nieliniowe, takie jak urządzenia energoelektroniczne, są głównymi przyczynami problemów z jakością energii. W artykule porównaliśmy teorię DQ i PQ w celu sterowania bocznikowym filtrem mocy czynnej za pomocą technik histerezy i PWM przy różnych obciążeniach nieliniowych (prostowniki sterowane i niesterowane) pod względem stopnia poprawy THD, jakości napięcia i strat przełączania. MATLAB / Simulink został wykorzystany jako narzędzie symulacyjne do uzyskania wyniku dla tego artykułu.
11
Content available remote Badania eksperymentalne zasilacza lampy ulicznej LED
PL
Praca dotyczy wpływu zmian rezystancji obciążenia oraz wartości skutecznej napięcia zasilającego na parametry eksploatacyjne zasilacza lampy ulicznej LED typu TECEO1. Badania eksperymentalne zostały przeprowadzone dla liniowego obciążenia rezystancyjnego zmieniającego się w zakresie od 10 Ω do 100 kΩ, dla obciążenia nieliniowego w postaci fabrycznego modułu LED oraz dla wartości skutecznej napięcia zasilającego zmieniającej się w zakresie od 100 V do 230 V. Podczas badań eksperymentalnych przeanalizowano także wpływ układu zasilania lampy ulicznej LED na odkształcenia prądu pobieranego z sieci elektroenergetycznej.
EN
The paper deals with an influence of changes in load resistance and the rms value of supply voltage on the exploitive parameters of the TECEO1 type LED street lamp power supply. Experimental studies were carried out for the linear load resistance ranging from 10 Ω to 100 kΩ, for nonlinear load in the form of a factory-made LED module and for the rms value of the supply voltage ranging from 100 V to 230 V. The influence of the power supply system of the LED street lamp on the deformations of the current taken from the power grid was also analyzed during the experimental studies.
EN
The Smart Grid environment gives more benefits for the consumers, whereas the power quality is one of the challenging factors in the smart grid environment. To protect the system equipment and increase the reliability, different filter technologies are used. Even though, consumers’ expectations towards the power quality are not fulfilled. To overcome these drawbacks and enhance the system reliability, a new Custom Power Devices (CPD) are introduced in the system. Among different CPDs, the Dynamic Voltage Restorer (DVR) is one of the voltage compensating devices that is used to improve the power quality during distortions. When the distortions such as voltage swell and sag occur in the distribution system, the control strategy in the DVR plays a significant role. In this article, the DVR performance using Proportional Integral (PI), Proportional Resonant (PR) controllers are analyzed. A robust optimization algorithm called Self Balanced Differential Evolution (SBDE) is used to find the optimal gain values of the controllers in order to reach the target of global minimum error and obtain fast response. Then, a comparative analysis is performed between different controllers and verified that the performance of PR controller is superior than the other controllers. It has been found that the proposed PR controller strategy reduces the Total Harmonic Distortion (THD) values for all types of faults. The proposed SBDE optimized DVR with PR controller reduces the THD value less than 4% under voltage distoration condition. The DVR topology is validated in MATLAB/SIMULINK in order to detect the disturbance and inject the voltage to compensate the load voltage.
13
Content available remote Wpływ trybu pracy lampy LED typu HUE na jej parametry elektryczne i optyczne
PL
W pracy przedstawiono i przedyskutowano wyniki pomiarów parametrów elektrycznych i optycznych lampy LED typu HUE emitującej światło białe. Przedstawiona lampa LED typu HUE może być sterowana bezprzewodowo. Parametry elektryczne i optyczne wybranej klasy lamp LED zostały zmierzone za pomocą autorskiego układu pomiarowego. Szczególną uwagę poświęcono wpływowi badanej lampy LED na parametry sieci elektroenergetycznej. Zbadano wpływ wartości napięcia zasilającego oraz wartości temperatury barwowej światła emitowanego przez badaną lampę LED na wartość współczynnika zawartości harmonicznych THD prądu zasilającego.
EN
In the paper electrical and optical properties of LED lamp of the HUE type emitting white light are analysed. This lamp makes it possible to remote control the mode of its operation. Properties of this class of lamps given by the producer was characterised and the authors’ set-up to measure electrical and optical parameters of the considered lamps is proposed. Attention was paid on parameters characterising influence of the LED lamp on the electroenergy network. Additionally, influence of feeding voltage, the fixed value of illuminance and correlated color temperature (CCT) of the emitted light on THD (Total Harmonic Distortion) is analysed and discussed.
EN
In this paper a modified space vector pulse-width modulation (SVPWM) technique for a three-phase T-type inverter is proposed that utilizes the state redundancies for fault-tolerant application. The performance of the T-type, 3-level inverter is analyzed with a three-phase induction motor load under the open-circuit fault condition of the inverter. The voltage space vectors of the three-level inverter under the open switch fault (open circuit fault) condition in any one leg of the three-phase inverter is analyzed and modified using the SVPWM adopted to overcome the problems of sudden stall at open switch fault conditions. Modelling and simulation of T-type 3-level inwerter using proposed modified space vector pulse width modulationis carried out in the MATLAB/SIMULINK environment. The experimental results are presented here for verification of the simulation results using real-time simulator (dSPACE 1103).
EN
The requirements relating to the emission of auxiliary AC supply sockets in traction vehicles have been extended in standard PN-EN 50121-3-2:2015 by voltage harmonics measurement. This applies to the public on-board AC supply grid which is accessible to all passengers. It is concerned with providing the quality of power supply which is required by computer devices and mobile phone rechargers. This article presents the requirements and test methods resulting from extended standard scope. Normative factors, for which levels of permissible voltage harmonics in the public supply grid of traction vehicle have been defined are discussed. Examples of comparative results obtained from measurements and analyses of voltage harmonics within on-board supply grids are also presented. The presented results include extended calculations of distortion factors for groups and subgroups of supply voltage harmonics. In order to improve the quality of voltage within the on-board grid, which did not meet the requirements, simulation calculations were performed and an additional output sinusoidal filter was proposed.
PL
Wymagania dotyczące emisji portów pomocniczego zasilania AC w pojazdach trakcyjnych zostały w normie PN-EN 50121-3-2 z 2015 roku rozszerzone o pomiar w zakresie harmonicznych napięcia. Dotyczy to publicznej sieci zasilania pokładowego ogólnie dostępnej dla pasażerów. Związane jest to z zapewnieniem jakości zasilania, która jest wymagana dla urządzeń komputerowych oraz zasilaczy telefonów komórkowych. W artykule przedstawiono wymagania oraz metody badań wynikające z rozszerzonego zakresu normy. Omówiono normatywne współczynniki, dla których określone są poziomy dopuszczalne emisji harmonicznych w napięciu publicznej sieci zasilania w pojeździe trakcyjnym. Przedstawiono również przykładowe wyniki porównawcze uzyskane na podstawie pomiarów i analiz harmonicznych w napięciu pokładowej sieci zasilania. Prezentowane wyniki obejmują rozszerzone obliczenia współczynników odkształceń dla grup i podgrup harmonicznych napięcia zasilania. W celu poprawy jakości napięcia w sieci pokładowej, która nie spełniała wymagań normatywnych wykonano obliczenia symulacyjne i zaproponowano dodatkowy wyjściowy filtr sinusoidalny.
16
Content available 2.5D im model with skewed rotor
EN
The papers deals with 2.5D induction motor model with skewed rotor. The model is based on two different IM with the same magnetic core: 55kW 2p=6 and 45kW 2p=8. Influence of the number of rotor slots and the number of slices on the torque ripple and magnetic field distribution in the air gap was considered.
PL
Artykuł przedstawia model 2,5D silnika indukcyjnego ze skosem w wirniku. Model silnika bazuje na silniku 6-biegunowym 55kW oraz 8-biegunowym 45kW o tym samym magnetowodzie. Zbadano wpływ liczby żłobków wirnika oraz liczby części modelu 2,5D silnika na tętnienia momentu oraz rozkład indukcji magnetycznej w szczelinie powietrznej.
PL
W pracy krótko scharakteryzowano ideę pomiaru natężenia prądu przy użyciu czujnika polarymetrycznego ze światłowodową cewką pomiarową. Zaprezentowano definicję oraz podstawowe właściwości dyskretnego przekształcenia Fouriera. Omówiono technikę wyznaczania wartości poszczególnych harmonicznych sygnału na wejściu i wyjściu polarymetrycznego czujnika natężenia prądu. Wyznaczono wartości błędów pomiaru oraz współczynnika zawartości harmonicznych – THD, a następnie sformułowano ogólne wnioski dotyczące wprowadzania zniekształceń towarzyszących procesowi przetwarzania realizowanemu w polarymetrycznym czujniku natężenia prądu. Dodatkowo określono wpływ stężenia molowego domieszki GeO2 w rdzeniu światłowodu (na przykładzie trzech standardów jednomodowych światłowodów telekomunikacyjnych wg ITU-T G.652, G.653 i G.655) oraz wpływ liczby zwojów pomiarowej cewki światłowodowej na zniekształcenia towarzyszące procesowi przetwarzania.
EN
In this paper briefly characterised the idea of measure of current using polarimetric current sensor with optical fiber coil. It shows the definition and basic properties of the Discrete Fourier Transform. It discusses the technique of determining the value of each harmonic of signal at the input and output polarimetric sensor current. Calculated the value of measurement errors and total harmonic distortion – THD, and formulated a general request for placing a distortion accompanying of processing realized in polarimetric current sensor. In addition, the impact of the molar concentration of the dopant GeO2 in the core of fiber (for example, three standards of single mode optical fiber ITU-T G.652, G.653 and G.655) and the impact of the number of turns of the measuring coil on the distortion accompanying the process of processing, have been determined.
PL
W pracy przedstawiono zmiany parametrów elektrycznych zamienników żarówek głównego szeregu przystosowanych do ściemniania. Wobec faktu, że producenci w specyfikacji zamienników lamp żarowych zadeklarowali możliwość współpracy z dowolnym regulatorem natężenia oświetlenia, zastosowano dwie metody ściemniania źródeł światła. W pierwszej wykorzystano tzw. regulację kąta przepływu (rozwiązanie stosowane w ściemniaczach tyrystorowych), w drugiej zaś regulowano amplitudą napięcia zasilającego (którą zrealizowano wykorzystując do tego celu autotransformator).
EN
The paper presents electrical parameter changes of prime set bulb equivalents suitable for dimming. Two methods of light dimming are used in accordance to fact that producers in the product specification of bulbs, declared a possibility of device cooperation with any dimmer. The first method deploys so called method of regulation of flow angle (solution used by thyristors dimmers), whereas the second method uses regulation of supplying voltage amplitude (by usage of autotransformer).
EN
This paper presents a high performance control scheme for a single phase uninterruptible power supply (UPS) inverter. In the proposed structure, a learning-type controller eliminates periodic disturbances and therefore guaranties high steady-state performance while an instantaneous feedback controller ensures fast dynamic response of the system. Analysis and design of each controller are presented and a brief stability analysis of the complete system is given. Finally to validate the proposed control scheme, simulation results of the system are presented.
PL
W artykule opisano metodę sterowania jednofazowym przekształtnikiem stosowanym w systemie UPS. Zastosowano układ uczący się co gwarantowało płynną pracę systemu. Bazujący na chwilowych wartościach sterownik w sprzężeniu zwrotnym zapewniał dobrą dynamikę.
EN
Increased sea transport with a constantly growing demand by ships for electric power means higher emission of pollutions generated by ships to the atmosphere. To turn off automatic generator sets which are the main source of air pollution emissions by ships mooring in the port a ship has to be connected to the power land network. Quality of electric power supplied from the land is of a great importance connected with security of the work of naval systems and economical ship functioning. Complicated computer steering systems more and more frequently used on ships are very sensitive to disturbances and require energy supply of a very high quality. In this article basic information about quality of electric power supplied to the ship from the land network and chosen ways of its improvement are presented.
PL
Zwiększony transport morski, przy ciągle rosnącym zapotrzebowaniu przez statki na energię elektryczną oznacza większą emisję zanieczyszczeń generowanych przez statki do atmosfery. W celu wyłączenia autonomicznych zespołów prądotwórczych, które są głównym źródłem emisji zanieczyszczeń powietrza przez statki cumujące w porcie jest podłączenie statku do elektroenergetycznej sieci lądowej. Jakość energii elektrycznej dostarczanej z lądu ma ogromne znaczenie związane z bezpieczeństwem pracy systemów okrętowych i ekonomicznym funkcjonowaniem statku. Stosowane coraz powszechniej na statkach skomplikowane komputerowe systemy sterowania są bardzo wrażliwe na zaburzenia i wymagają zasilania o bardzo wysokiej jakości. W niniejszym artykule przedstawiono podstawowe informacje dotyczące jakości energii elektrycznej dostarczanej na statek z sieci lądowej oraz wybrane sposoby jej poprawy.