Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  tornado
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In June 2021, a tornado struck a large area in southern Moravia, causing extensive damage to property owned by individuals and legal entities. A need thus arose to speed up the process of estimating the amount of insurance indemnity. This process involved local inspections and subsequent assessment of quotations from construction companies for repairs, as the adjusters did not have the time and resources to estimate the amount of damage using the usual method, i.e. an itemised budget containing a list of works, supplies and services necessary to restore a structure to its original condition based on an on-site inspection. This article contains a retrospective analysis of the accepted quotations and evaluates differences in terms of scope and price compared to the standard procedure. Four apartment buildings were selected for assessment of the insulation and roof repairs. The results show that there are clear discrepancies between the price as determined by the itemised budget using the usual prices and the construction companies’ quotations. The analysis of the selected buildings has indicated that the quotations can by no means be accepted without first establishing the total damage and its actual scope. Major damage caused by a natural disaster will still have to be estimated on the basis of a personal inspection of the damaged property and preparation of an itemised budget created in line with the applicable pricing system.
EN
This study documents the atmospheric conditions and the development of a tornadic supercell in the Czech Republic, which occurred on the early evening on 24 June 2021. I used the data from the ERA5-reanalysis, vertical atmospheric sounding, synoptic map, and a Sentinel-2 satellite image to determinate the tornado route. As a result of the analysis, it can be concluded that the development of this tornadic supercell was caused by high CAPE values, amounting to around 5,000 J·kg-1, 0-6 km AGL wind shear 30 m·s-1, storm-relative helicity with values of 150 m2·s-2 and a wavy atmospheric front. The tornado occurred around 19:30 local time (1730 UTC) in the town Hrušky and moved north-east, reaching the town Hodonín. Based on satellite image derived from Sentinel-2, the widest point of the tornado reached 70 meters; it traveled a distance of about 20 kilometers and had a force of EF3/T5 on the Fujita/TORRO scale. As a result of this event, 6 people lost their lives, 200 people were seriously injured, and hundreds of buildings and cars were destroyed. Further studies on strong thunderstorm incidents in Europe are necessary for their better understanding and prediction.
EN
International scales describing the intensity of tornadoes are investigated along with reports from the Polish Government Security Centre on all types of wind storms in Poland. Then, collected tornado reports for the years 1899-2019 in Poland, a set of the annual maximum gust wind speeds measured at 39 meteorological stations from 1971 to 2005 (35 years), descriptions of Poland’s strongest wind storms in the 21st century, estimating the risk of significant strong and extreme winds in Poland, and classification of maximum wind speeds by Lorenc (2012) are presented. Based on these data, i.e. measured and estimated wind speeds, this paper proposes two separate intensity scales to categorize synoptic, thunderstorm, and downslope winds (in the Tatra and Karkonosze regions), derechos, tornadoes, and downbursts, i.e. all types of wind storms. These scales are simpler than the one put forward by Lorenc (2012). These two scales cover a range of maximum wind speeds from 20 to 90 m/s. This proposal is only applicable to Poland. Other countries may determine whether it applies to them.
PL
Różnego rodzaju burze wiatrowe w Polsce każdego roku stanowią potencjalne duże zagrożenie strat finansowych w gospodarce, zdrowia i życia ludzkiego w naszym kraju. W niniejszym artykule przedstawiono: raport Rządowego Centrum Bezpieczeństwa (RCB) o potencjalnych zagrożeniach naturalnych w Polsce, międzynarodowe skale opisujące intensywność trąb powietrznych, badania dotyczące liczności trąb powietrznych w latach 1899-2019 w Polsce, zestaw rocznych maksymalnych prędkości wiatru w porywach mierzonych na 39 stacjach meteorologicznych w latach 1971-2005 (35 lat), opisy najsilniejszych burz wiatrowych w Polsce w XXI wieku, oszacowanie ryzyka silnych i ekstremalnych wiatrów w Polsce i klasyfikację maksymalnych prędkości wiatru w Polsce i skutki ich działania, zaproponowaną w 2012 roku przez Lorenc [10]. Na podstawie powyższych danych zaproponowano dwie osobne skale klasyfikacji maksymalnych prędkości wiatru i skutki ich działania dla wszystkich burz wiatrowych, tj.: synoptycznych burz wiatrowych, burz wiatrowych lokalnych, burz w rejonach górskich (wiatru halnego w rejonie Tatr lub fenu w rejonie Karkonoszy), trąb powietrznych, szkwałów i rozległych burz wiatrowych typu derecho. Te dwie skale obejmują zakres maksymalnych prędkości wiatru od 20 do 90 m/s.
PL
Głównym celem pracy było wyróżnienie rodzajów sytuacji synoptycznych, podczas których występowało zjawisko intensywnej tornadogenezy. Dodatkowym celem opracowania było wskazanie położenia geograficznego obszarów pochodzenia mas powietrza, w jakich formowały się najsilniejsze trąby powietrzne w skali Fujity (F3 i F4) oraz analiza częstości adwekcji z wyznaczonych obszarów źródłowych. Baza danych niniejszej pracy składała się z części ogólnej (w pełni zweryfikowane raporty European Severe Weather Database o liczbie, sile i miejscu wystąpienia trąb powietrznych w latach 1998-2013 – 1 772 trąb powietrznych z obszaru Europy, w tym 102 przypadki w granicach Polski) oraz bazy wyselekcjonowanej, zawierającej dane m.in. o trąbach powietrznych występujących w trakcie zjawiska intensywnej tornadogenezy, towarzyszących im dolnych i górnych sytuacjach synoptycznych (mapy z archiwum www.wetter3.de), 72-godzinnych trajektoriach wstecznych mas powietrza napływających nad miejsce wystąpienia trąb powietrznych o sile F3 i F4 (wykorzystano model NOAA HYSPLIT 4.1). Zjawisko intensywnej tornadogenezy zdefiniowano jako wystąpienie co najmniej dwóch trąb powietrznych w ciągu 12 godzin w miejscach oddalonych od siebie maksymalnie o 150 km lub wystąpienie trąb powietrznych jako sekwencji zjawiska podążającego za frontami atmosferycznymi. Kryterium procesu intensywnej tornadogenezy spełniło 40% (718) trąb powietrznych w badanym okresie. Wyróżniono trzy główne sytuacje synoptyczne w dniach intensywnej tornadogenezy, tj. z frontami atmosferycznymi (51%), bezfrontowe (44%), z frontogenezą, frontolizą oraz frontami górnymi (5%). Łącznie główne sytuacje synoptyczne podzielono na 28 typów, z czego front chłodny oraz zatoka niskiego ciśnienia najczęściej towarzyszyły zjawisku intensywnej tornadogenezy. Silne trąby powietrzne o prędkości wiatru powyżej 250 km/h (F3 i F4) stanowiły tylko 3% (46) przypadków w badanym okresie. Analiza szlaków przemieszczania się mas powietrza trzy doby przed adwekcją nad miejsce obserwacji silnych trąb powietrznych wykazała przewagę powietrza morskiego nad kontynentalnym na poziomach 2 500 m i 5 000 m, a kontynentalnego nad morskim na wysokości 500 m. Wyróżniono szesnaście geograficznych obszarów pochodzenia mas powietrza 72-godz. przed napływem nad miejsca intensywnej tornadogenezy w Europie, ograniczonych równoleżnikami 25°N i 57°N oraz południkami 70°W i 25°E. Morze Śródziemne, środkowa i wschodnia część północnego Atlantyku i Półwysep Bałkański to obszary, które najczęściej zasilały adwekcje nad miejsca intensywnej tornadogenezy.
EN
The main purpose of this study was to distinguish types of synoptic situations corresponding to the intense tornadogenesis. An additional objectives of the study were to indicate the geographical location of air masses source in which the intense tornado (F3 and F4, Fujita scale) were formed, and analysis of the frequency of air masses fetch from the designated source areas. The database of this work consisted of a general part (entirely verified reports of the European Severe Weather Database on the number, strength and location of tornadoes in 1998-2013, i.e. 1 772 tornadoes from Europe, including 102 cases within Poland) and a selected database containing the data: about tornadoes occurring during the intense tornadogenesis, accompanying lower and upper synoptic situations (maps from the archive www.wetter3.de), 72-hour backward trajectories of air masses fetch over the site of the intense tornados F3 and F4 (using NOAAHYSPIT 4.1 model). The phenomenon of the intense tornadogenesis was defined in this study as the occurrence of two tornadoes within 12 hours at least in the sites located up to 150 km or the occurrence of tornadoes as a sequence of phenomena following the atmospheric fronts. There were 40% (718) cases of tornadoes within the intense tornadogenesis in analyzed period. Three main synoptic situations were distinguished in the days of intense tornadogenesis, i.e. with atmospheric fronts (51%), without atmospheric fronts (44%), with frontogenesis, frontolysis and upper fronts (5%). In total, the main synoptic situations were divided into 28 types, of which the cold front and the trough most often corresponded to the phenomenon of intense tornadogenesis. The intense tornadoes with wind speeds above 250 km/h (F3 and F4) occurred in 3% (46) cases in the analyzed period. Analysis of the 3-day air masses backward trajectories revealed the dominance of maritime air masses at 2 500 m and 5 000 m levels, and the continental air masses at 500 m level within the intense tornadoes occurrences. There were 16 geographical sources of air masses fetch over of the site of intense tornadogenesis in Europe, limited by latitudes of 25°N and 57°N and longitudes of 70°W and 25°E. Mediterranean Sea, the central and the eastern part of the North Atlantic, Balkan Peninsula are the areas that most often supplied air masses fetch over the sites of the intense tornadogenesis.
PL
Przedstawiono międzynarodowe skale opisujące intensywność tornad, raport Rządowego Centrum Bezpieczeństwa dotyczący wichur i tornad, częstość występowania tornad i propozycję klasyfikacji maksymalnych prędkości wiatru w Polsce oraz skutków ich działania. Informacje poddano analizie i na podstawie dostępnych danych statystycznych zaproponowano dwie skale klasyfikacji: skalę silnych wiatrów synoptycznych, halnych i fenowych oraz skalę intensywności tornad i szkwałów – oznaczoną jako skala P.
EN
The article presents an overview of international scales, describing the intensity of tornadoes. There is the report from the Government Security Centre on storms and tornadoes, the incidence of tornadoes in Poland, and the proposed classification in 2012 by Lorenc for the maximum wind speed in Poland and effects of their actions. This information was analysed and on the basis of available statistical data two separate intensity scales of strong winds, tornadoes and downbursts in Poland are proposed.
PL
W artykule przedstawiono przegląd międzynarodowych skali opisujących intensywność tornad, raport Rządowego Centrum Bezpieczeństwa dotyczący silnych wiatrów i tornad, częstość występowania tornad i propozycję klasyfikacji maksymalnej prędkości wiatru w Polsce z 2012 r. oraz skutków ich działania. Wymienione informacje poddano analizie i na podstawie dostępnych danych statystycznych zaproponowano dwie skale klasyfikacji dla naszego kraju: silnych wiatrów synoptycznych, halnych i fenowych oraz intensywności tornad – oznaczonej jako skala P.
EN
The article presents an overview of international scales, describing the intensity of tornadoes. There is the report from the Government Security Centre on strong winds and tornadoes, the incidence of tornadoes in Poland, and the proposed classification in 2012, for the maximum wind speed in Poland and effects of their actions. This information was analysed and on the basis of available statistical data two separate intensity scales of strong winds and tornadoes in Poland are proposed.
EN
The synoptic analyses of two different tornado cases, observed in Latvia and Poland in the summer of 2012, are examined in this paper. The first of them, the tornado in Latvia seemed to be a “textbook example” of tornado occurrence. Its development took place in the contact zone of the warm, tropical air, characterized by a very high CAPE (Convective Available Potential Energy), with cold and moist polar marine air mass behind the convergence line that determined very good conditions for convective updraft. Additionally, the moderate environmental wind shear favoured the sufficient condition for concentrating the atmosphere’s vorticity into well-organized strong rotating upward motions that produced the supercell structures and tornado. Thus, from the forecaster’s point of view, the occurrence of this severe convective event was not a surprise. This phenomenon was predicted correctly more than a dozen hours before the tornado occurred. The second event occurred in the north of Poland and was associated with a thunderstorm where a supercell was formed in conditions of low CAPE but favourable wind profile, both vertical and horizontal. Helical environments (characterized by large shear vectors that veered with height in the lowest three kilometres, especially the nearest one kilometre) were arguably the most important factor that determined the Polish tornado’s occurrence. In this case the analysis of the synoptic situation was not so clear and the superficial analysis, even post factum, regarding radar, satellite or detection maps might have suggested “quite a normal” summer thunderstorm. However, the detailed examination showed the reasons why tornado genesis took place. The potential conditions for the occurrence of this severe phenomenon were indicated by forecasters, although the forecasts were less exact with regard to the place of occurrence and the heaviness of the strike.
EN
The aim of this work was to perform the real case study for the US Surry Nuclear Power Plant which was touched down by tornado in 2011 causing the electrical switch yard destruction and loss of offsite power. Probabilistic methods have been applied to assess the reliability of the reactor shutdown and effective heat removal after this accident. The reactor protection system and auxiliary feedwater system were thoroughly analysed in the context of their safety features designed to prevent the reactor core damage. The emergency power system reliability has been also considered due to the fact that some components of the safety systems are electrically operated. Moreover, time-dependent analysis has been performed in order to address the level of damages after an extreme external event like tornado. Depending on the severity of such events the time required to restore the electrical grid may be significantly different and longer than 24 hours. The reliability and requirements for safety systems are changing with time and these changes have been taken into account as well.
9
Content available remote Tornada wywołane przez cyklony zwrotnikowe w Stanach Zjednoczonych (1950-2012)
PL
Celem pracy jest scharakteryzowanie rzadkiego zjawiska tornad wywołanych przez cyklony zwrotnikowe (TCT) oraz przedstawienie przebiegu ich występowania w Stanach Zjednoczonych w latach 1950-2012. Przedstawiono także warunki sprzyjające ich powstawaniu. Tego typu zjawiska najliczniej tworzą się w przedniej, prawej ćwiartce w stosunku do toru przemieszczania się cyklonu. W podanych latach na północnym Atlantyku uformowało się 737 cyklonów zwrotnikowych (398 huraganów oraz 339 burz i depresji zwrotnikowych). Ponad 190 z nich dotarło do wybrzeży USA, a 58 wywołało serie wirów (w ramach tych serii zanotowano ok. 1655 tornad). Ponadto zanotowano 356 pojedynczych tornad, niezwiązanych ze zjawiskiem tornado outbreak. TCT najczęściej występowały w godzinach popołudniowych. Najwięcej tornad było jesienią. Wiąże się to ze wzmożoną aktywnością huraganów w tym okresie. Większość przypadków osiągała najmniejszą intensywność w skali Fujity. Huragany docierając nad ląd nie otrzymują już dostatecznej ilości energii, przez co słabną i zanikają. Dlatego zdecydowana większość przypadków TCT była na wybrzeżu, na obszarze stanów Floryda i Teksas.
EN
The aim of this study was to characterise the phenomenon of tornadoes that arise from the transition of tropical cyclones as well as the analysis of their occurrence in the U.S. during 1950-2012. The conditions favouring the formation of Tropical Cyclone Tornadoes are also presented. Tornadoes most often form in the cyclone’s front right quadrant relative to its direction of travel. During the period studied, 737 tropical cyclones formed over the North Atlantic (398 hurricanes and 339 tropical storms or tropical depression), almost 190 of them reached the U.S. coast and 58 resulted in a series of tornadoes (around 1655 tornadoes were recorded overall). Also were noted 356 individual tornadoes, unrelated to the tornado outbreak. TCT usually occurred in the afternoon and most were recorded in autumn due to the elevated hurricane activity in this period. The majority of cases reached the lowest levels of the Fujita scale. Hurricanes reaching land no longer receive enough energy so they weaken and disappear which is why, in the vast majority of cases, TCT affect coastal areas (Florida and Texas).
PL
W artykule przedstawiono przykłady uszkodzeń budynków mieszkalnych i gospodarczych, stanowiących zwartą zabudowę jednorodzinną, w wyniku działania trąby powietrznej 15 sierpnia 2008 r.
EN
This paper presents the examples of damages of residential and farm buildings forming the compact built-up area, due to tornado in 15th August 2008.
PL
Przedstawiono opis i klasyfikację uszkodzeń i zniszczeń budynków mieszkalnych, gospodarczych i użyteczności publicznej po przejściu trąby powietrznej 15 sierpnia 2008 r. Oszacowano prędkość wiatru trąby, omówiono proces odbudowy uszkodzonych budynków i podano propozycję rozwiązań technicznych zmniejszających skutki działania silnych wiatrów.
EN
Tornado near Opole passed over the area of six villages in the early evening of Friday 15th August 2008 and caused severe damage to buildings and infrastructure. An assessment of buildings performance and the engineering estimates of wind velocity were conducted in that case for the first time in Poland. The paper ends with recommendations for design and construction of buildings against very strong winds.
PL
20 VII 2007 r. eksplozja gwałtownej konwekcji dotknęła liczne kraje Europy, a w Polsce powodując tornado. Niniejsza praca stanowi kontynuację części I: w tej części pracy skoncentrujemy się na szczegółowej analizie powstawania superkomórki i zjawiska tornada z wykorzystaniem przeprowadzonych symulacji komputerowych. Odbiciowość z radarów Ramża, Pastewnik i Legionowo została złożona tak, aby odtworzyć 3-wymiarową historię rozwoju systemu konwekcyjnego nad południową Polską z superkomórką burzową generującą tornado w pobliżu Częstochowy. Do interpretacji kompozycji radarowych wykorzystano symulacje komputerowe ze zmienną rozdzielczością, dane satelitarne i dane z systemu detekcji wyładowań PERUN, co pozwoliło wnioskować nawet o takich subtelnych procesach, jak prawo i lewoskrętność ruchu układów wiatrowych konwekcyjnego systemu tornada. Tym niemniej konwekcyjne struktury wody chmurowej, symulowane przez model, pozostały niedoszacowane - istnieje przypuszczenie, że w danym przypadku o nieudanej prognozie chmury konwekcyjnej zadecydowała zbyt skąpa rozdzielczość modelu w obszarze ageostroficznego przepływu mas powietrza pod prądem strumieniowym.
EN
On the 20 July 2007 explosive convection weather event has affected number of Europe countries and promoting tornado in Poland. This work is continuation of the part I: here we concentrate on the detail analysis of supercell and tornado generation basing on computer simulations by COSMO-Lm nonhydrostatic model. The radar reflectivity from Ramża, Pastewnik, Legionowo Doppler radars has been used in a way to restore - possibly real - 3D development history of the convective system over southern Poland with the giant supercell storm that produced tornado near Częstochowa. To interpret radar compositions we used computer simulations with different resolutions, satellite data and lightening detection system data PERUN. Many synoptic futures were correctly reproduced by the model and helped to understand the mechanisms of the case and deduce even such subtle processes like right and left moving wind patterns of tornado convective system. Nevertheless the cloud water convective structures as simulated by model remain underestimated. One of the fault reasons is that the proper radar assimilation scheme was not adopted, but the second suspicion is that the ageostrophic flow just under the jet stream was not adequately represented.
13
Content available remote Tornado w rejonie Częstochowy – 20 lipca 2007. Część II: Analiza synoptyczna
PL
20 VII 2007 r. eksplozja gwałtownej konwekcji dotknęła liczne kraje Europy: Anglię, Niemcy, Polskę i Ukrainę. Groźne burze spowodowały ekstremalne powodzie (Wyspy Brytyjskie i Ukraina) oraz niszczące wiatry, włączając tornado w Polsce. Przypadek ten był szeroko dyskutowany, zwłaszcza w mediach brytyjskich, nierzadko upatrujących źródła jego wystąpienia w zmieniającym się klimacie. Dla przykładu, komentarz renomowanego Instytutu Walkera (2007) wskazuje, m.in., że przyczyną powodującą, iż prąd strumieniowy latem 2007 został przemieszczony dalej na południe niż normalnie (co stanowiło kluczową osobliwość powodzi) była "niezwykła aktywność azjatycko-hinduskiego monsunu letniego" i dalej wyraża nadzieję, iż "eksperymenty z modelami atmosferycznymi ...wyjaśnią te możliwe dalekie związki". Do analizy synoptycznej wykorzystano symulacje modelem niehydrostatycznym COSMO-Lm nad Europą. Wiele charakterystycznych osobliwości procesu synoptycznego zostało poprawnie odtworzonych przez model i pomogło zrozumieć mechanizmy sterujące tym przypadkiem.
EN
On the 20 July 2007 explosive convection weather event has affected number of Europe countries: England, Germany, Poland and Ukraine. Severe storms caused extreme floods (Britain and Ukraine) and damaging winds, with tornado in Poland. The case has been broadly discussed, especially in British media, not rarely suggesting its climate change origin. For instant, the Walker Institute briefing note, 2007, indicates among others that the reason why " the jet stream was further south than normal during summer 2007" (recognized as the key feature for floods) was "a very vigorous Indian/Asian Summer Monsoon” and hopes in "experiments with atmospheric models .. to clarify these possible links". Here, for synoptic analysis purpose, additionally to standard weather charts, radar and satellite pictures, COSMO - Lm nonhydrostatic model simulations over Europe has been performed and thoroughly 3D examined. Many synoptic futures were correctly reproduced by the model and helped to understand the mechanisms that control the case.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.