Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  topological indices
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A topological index is a numeric quantity associated with a network or a graph that characterizes its whole structural properties. In [Javaid and Cao, Neural Computing and Applications, DOI 10.1007/s00521-017-2972-1], the various degree-based topological indices for the probabilistic neural networks are studied. We extend this study by considering the calculations of the other topological indices, and derive the analytical closed formulas for these new topological indices of the probabilistic neural network. Moreover, a comparative study using computer-based graphs has been carried out first time to clarify the nature of the computed topological descriptors for the probabilistic neural networks. Our results extend some known conclusions.
EN
The present work proposes two new Euclidean distance functions, six new centrality measures as well as several new entropies definable on any complex network. It is demonstrated on four spatial and two social real-world datasets that these concepts are applicable in network data mining. Also, several new topological indices are introduced and their basic computational properties are established.
3
Content available remote Electrotopological structural parameters for polychlorinated biphenyls
EN
Polychlorinated biphenyls (PCBs) have been characterized with new topological indices: E-state parameter and electrotopological index TIE. Their discriminating power and degeneracy level has been presented and discussed. It has been shown that electrotopological index TIE may be utilised as a structural parameter in the structure-retention relationships due to its high discrimination power and low degeneracy.
PL
Do charakterystyki polichlorowanych bifenyli wykorzystano dwa nowe indeksy topologiczne: parametr E-state oraz indeks elektrotopologiczny TI(E);. Dokonano oceny ich zdolności dyskryminacyjnej oraz stopnia degeneracji. Wykazano, że ze względu na wysoką zdolność dyskryminacji oraz niski stopień zdegenerowania indeks elektrotopologiczny TI1- może być wykorzystywany w zależnościach struktura-retencja.
PL
Zbadano możliwość wykorzystania krajowych związków powierzchniowo czynnych (ZPC) z szeregu "Rofamów" (ok-syetylenowanych estrów metylowych kwasu oleinowego) w technologii postaci leku. Określaną metodą H NMR rzeczywistą średnią zawartość segmentów oksyetylenowych (HTE) wykorzystano do oznaczania analitycznego poziomu równowagi hydrofilowo-lipofiłowej (HLB/, H/L). Deklarowana przez producenta (n TE) i ustalona doświadczalnie (TITE) liczba segmentów oksyetylenowych w szeregu homologicznym "Rofamów" umożliwiła weryfikację ich ciężaru cząsteczkowego (odpowiednio M i M), obliczenie indeksów topologicznych (LIC i LSIC), parametru rozpuszczalności (8 i 8), a także strukturalnego poziomu równowagi hydrofilowo-lipofilowej (HLB) metodami Griffina, Daviesa, HLBR (wymagana wartość HLB) i H/L. Równaniami korelacyjnymi opisano zależności między liczbą segmentów oksyetylenowych zawartych w strukturze "Rofamów" a HLB, H/L i i indeksami topologicznymi 27C i LSIC. Wykazano, że wartości strukturalnego i analitycznego poziomu HLB są zbliżone, co pozwala na doświadczalne oszacowanie wartości HLB danego ZPC, a więc ocenę jego przydatności praktycznej. Najlepszymi właściwościami użytkowymi pod względem farmaceutycznym (jako promotory przejścia przezskórnego, solubilizatory oraz emulgatory typu O/W) charakteryzowały się "Rofamy" o TITE 2:8.
EN
Possibility of the application of domestic surfactants (ZPC) from the "Rofam" series (oleic acid oxyethylenated methyl esters) in a drug form technology has been investigated. The real mean number of oxyethylene units ((n) over bar (TE)), measured by H-1 NMR, has been used to determine the analytical level of hydrophylic-lipophylic equilibrium (HLB, H/L). The number of oxyethylene units in the,Rofam" homologous series, declared by producer (n(TE)*) as well as experimentally found (n(TE)), made possible verification of their molecular weights (M* and M, respectively) and calculation of the topological indices (SigmaIC and SigmaSIC), solubility parameters (delta* i delta) and structural level of hydrophylic-lipophylic equilibrium (HLB), using methods by Griffin or Davies, as well as HLBR (required HLB value) and H/L. Dependences between the number of oxyethylenated units in the "Rofam" structure and HLB, H/L and the topological indices (SigmaIC and SigmaSIC) have been described using correlation equations. It was demonstrated that the values of structural and analytical HLB levels are similar what makes the experimental evaluation of HLB value of chosen ZPC possible. This let estimate of ZPC practical usability. "Rofam" products characterized with n(TE) greater than or equal to8 showed the best functional properties from the pharmaceutical point of view, as transdermal transition promotors, solubilizers and emulsifiers of oil/water type.
EN
(Received April 9th, 2001; revised manuscript November 21st, 2001) An improved numerical procedure is presented in order to enhance the possibilities of fitting polynomial equations to predict log P data within the realm of the QSAR/QSPR theory. The use of real exponents instead of restricting to integer ones for the variables in the mathematical equations gives better results and a minor number of independent variables are needed to achieve a given accuracy degree. Some possible future extensions of the method are pointed out.
PL
Omówiono właściwości indeksów topologicznych polichlorowanych bifenyli jako potencjalnych parametrów strukturalnych w zależnościach struktura - aktywność. Stwierdzono zróżnicowaną zdolność dyskryminacyjną badanych indeksów topologicznych oraz malejący stopień ich degradacji przy przejściu od indeksów opartych na macierzy sąsiedztwa do indeksów wyznaczonych z wykorzystaniem macierzy odległości.
EN
The properties of topological indeces for PCBs which could be used as potential structural parameters in structure - retention relationships were calculated and discussed. The examined topological indeces are characterized by varying discrimination ability and decreasing degeneracy on moving from indeces calculated from adjacency matrix to those calculated from distance matrix.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.