A three-dimensional finite element model of the lower cervical spine was established to evaluate the biomechanical stability and stress distribution of the new lower cervical interzygapophyseal fusion device (IZFD) developed by ourselves under different construct. The aim of this study was to provide theoretical basis for further clinical application. Methods: A normal fresh cadaveric specimen (male, 35 years old) was used to establish an intact three-dimensional finite element model of C3–C6. On this basis, the comparative finite element models of the lateral mass screw rod (LMSR) system and LMSR+IZFD were established. Only C4–C5 is fixed in the lateral mass. The range of motion (ROM) and stress distribution in the flexion,extension, lateral bending and rotation of the C4–C5 segment under the three constructs were analyzed. Results: The ROM and stress distribution of the three-dimensional finite element model under load construct were within a reasonable range, which proved the validity and reliability of the model. The ROM and stress distribution of C4–C5 segment was significantly decreased in both LMSR and LMSR+IZFD constructs than those in the intact construct. The ROM and stresss distribution were even smaller in LMSR+IZFD construct than in LMSR construct. Conclusions: The IZFD combined with LMSR system can provide satisfactory stability for the lower cervical spine, and the IZFD can further improve the fixation effect of the LMSR system.
2
Content available remote Research advancing the design of large span deep corrugated metal culverts
EN
While it has long been understood that culvert response to live load depends on three dimensional effects, and that design of these heavily redundant structures should account for ultimate strength, it has only recently been possible to measure and calculate this behaviour. Laboratory tests on a deep corrugated metal box culvert of 10m span are described, including tests before burial and one test of the shallow buried structure up to the ultimate strength limit. Three dimensional finite element analysis is then discussed. The ultimate strength test demonstrates the substantial reserve capacity due to three dimensional load spreading. Finally, the potential for undertaking design using parametric studies based on three dimensional finite element analyses is illustrated.
PL
Mimo tego, że od dawna rozumiemy, że reakcja przepustów na obciążenia zmienne zależy od sił działających w trzech wymiarach, a podczas projektowania tych wysoce redundantnych konstrukcji należy brać pod uwagę ich wytrzymałość graniczną, dopiero niedawno pojawiła się możliwość mierzenia i obliczania takiego zachowania. W tej pracy opisano testy laboratoryjne przepustu skrzynkowego ze stalowej blachy falistej o głębokiej fali o rozpiętości 10 m, w tym testy przed zasypaniem oraz jeden test konstrukcji z płytkim naziomem aż do granicy wytrzymałości. Następnie omówiona jest trójwymiarowa analiza elementów skończonych. Test wytrzymałości granicznej pokazuje znaczącą rezerwę wytrzymałości dzięki rozprzestrzenianiu się obciążeń w trzech wymiarach. Na koniec przedstawiono potencjał projektowania przy użyciu badań parametrycznych opartych o trójwymiarowe analizy elementów skończonych.