A complexometric method for the determination of mercury in the presence of other metal ions based on the selective masking ability of thioglycollic acid towards mercury is described. Mercury(II) present in a given sample solution is first complexed with a known excess of EDTA and the surplus EDTA is titrated against lead nitrate solution at pH 5.0-6.0 (hexamine) using xylenol orange as indicator. A known excess of thioglycollic acid solution (1%) is then added, the mixture is shaken well, and the EDTA released from the Hg-EDTA complex is titrated against standard lead nitrate solution. Reproducible and accurate results are obtained for 1.6-80 mg of mercury with relative error 0.7% and standard deviation <0.1 mg. The interference of various ions was studied. This method was applied to the determination of mercury(II) in its alloy compositions.
PL
Opisano kompleksometryczną metodę oznaczania rtęci(II) w obecności innych jonów, w której wykorzystano selektywne wiązanie jonów rtęci za pomocą kwasu tioglikolo-wego. Rtęć w próbce jest początkowo kompleksowana znanym nadmiarem EDTA i nadmiar EDTA jest odmiareczkowywany za pomocą roztworu azotanu ołowiu przy pH 5.0—6.0 w buforze heksaminowym w obecności oranżu kśylenolowego jako wskaźnika. Następnie dodaje się 1% roztwór kwasu tioglikolowego, mieszaninę wstrząsa, a nadmiar uwolnionego EDTA odmiareczkowuje roztworem azotanu ołowiu. W zakresie od l .6 do 80 mg rtęci(II) uzyskuje się wyniki z błędem względnym 0,7% i odchyleniem standardowym mniejszym od O, l mg. Badano wpływ szeregu jonów, a metodę zastoso-wano do oznaczania rtęci w stopach.