Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  thermocycling
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
An analysis of the operating conditions of gas turbine engines, their components, and the destruction causes was carried out. The designer problems of tribo-joints operating under difficult conditions of force and temperature loads are singled out. The study aimed at obtaining the comparable quantitative dependences of blade material wear, taking into account the role of both cyclical changes in the temperature of the gas flow under the conditions close to real ones, and their frictional characteristics. Deformable heat-resistant nickel alloys and foundry heat-resistant nickel alloys from which T-shaped samples were made, were chosen for the research. The tests were carried out on the developed gas dynamic stand, which simulates the working conditions of the bandage joints of the bladed turbomachines of gas turbine installations. The intensity of wear was determined as the ratio of the worn material volume to the number of load cycles under different temperature conditions. The wear resistance of three-way connections operating under the conditions of non-stationary thermal loads and fluctuations in the contact was considered. It was shown that thermal cycling leads to a decrease in the wear resistance of heat-resistant nickel alloys by 2–3 times and depends on the average temperature of the cycle. It was found that resistance to the wear, and also the character of change of coefficient of friction is mainly determined by the terms of education and destruction of the protective superficial layer. Basic factors managing tribology processes in the zone of contact were determined.
EN
Producers of hydraulic elements introduce new structural solutions and new materials. The aim of these activities is to increase the quality, reduce the costs, and shorten the assembly time of hydraulic elements. Consistently, with the requirements provided by the standards and technical specifications, the manufactured elements need to undergo tests of the resistance to variable temperatures and internal pressure loads. To reduce the time of tests and provide safety, the pressure applied to tested elements is higher than the load that they are exposed to while in regular operation. Additionally, the increased frequency of temperature changes is applied for the fluid, which flows through the system as well as a difference between the temperature of warm and cold fluid higher than in regular operation. Such tests are supposed to confirm the reliability of the tested structural solutions used in pipes and fittings and reveal problems connected with the impact of different types of materials and their combinations on hydraulic element systems. Commonly used tests stands are characterized by a large size and high energy needs. The aim of this study is to present the design and operation of a simple stand for tests of hydraulic elements and specimens whose internal surfaces are affected by the flow of fluid with higher pressures and variable temperatures. The analysed system is featured by smaller size, higher energy efficiency, and it needs less fluid for tests. Moreover, it enables the control of the test parameters in compliance with safety requirements.
PL
Producenci elementów hydraulicznych wprowadzają nowe rozwiązania konstrukcyjne i materiały. Celem tych działań jest zwiększenie jakości, zmniejszenie kosztów oraz skrócenie czasu montażu elementów hydraulicznych. Zgodnie z zaleceniami norm oraz wymaganymi aprobatami technicznymi produkowane elementy muszą przejść badania odporności na zmienne temperatury i obciążenia wewnętrznym ciśnieniem. W celu skrócenia czasu trwania testów i zapewnienia bezpieczeństwa elementy poddawane są obciążeniu większym ciśnieniem niż podczas normalnej eksploatacji. Dodatkowo stosuje się zwiększoną częstotliwość zmian temperatury przepływającej cieczy przez układ oraz większą różnicę pomiędzy temperaturą cieczy ciepłej i zimnej, niż ma to miejsce w docelowych instalacjach. Tak prowadzone badania mają na celu potwierdzić niezawodność stosowanych rozwiązań konstrukcyjnych złączek oraz problemy związane z zastosowaniem różnych typów materiałów i ich kombinacji na elementy układów hydraulicznych. Obecnie stosowane stanowiska badawcze posiadają znaczne gabaryty i charakteryzują się dużym zużyciem energii. Celem pracy jest przedstawienie budowy i sposobu działania prostego w budowie stanowiska do badań elementów hydraulicznych i próbek poddawanych od wewnętrznej strony przepływowi cieczy o podwyższonym ciśnieniu i zmiennej temperaturze. Przedstawiony układ cechuje się mniejszymi gabarytami, mniejszym zapotrzebowaniem na energię i ciecz wykorzystywaną podczas badania. Ponadto umożliwia kontrolę parametrów badania przy zachowaniu wymogów bezpieczeństwa.
PL
Mikroprzeciek jest główną przyczyną występowania próchnicy wtórnej w okolicy wypełnień stomatologicznych. W pracy badano wpływ cyklicznych obciążeń cieplnych na rozwój szczeliny brzeżnej dla 2 nanohybrydowych materiałów kompozytowych w wypełnieniach klasy I w ludzkich zębach trzonowych. Po każdych 2000 cykli (do 20000) próbki były oceniane na mikroskopie stereoskopowym stosując metodę penetrantu. Pomiarów długości szczeliny brzeżnej dokonano z wykorzystaniem systemu analizy obrazu. Uzyskano wyniki pomiarów długości szczeliny brzeżnej w zależności od ilości cykli termicznych. Wzrost szczeliny brzeżnej może być opisany wielomianem 3 stopnia, a szybkość rozwoju szczeliny zależy w szczególności od rodzaju systemu wiążącego oraz od interakcji między materiałami, właściwości powierzchni tkanek oraz od wpływu warunków w jamie ustnej.
EN
Microleakage is a major factor contributing to the occurrence of secondary carious lesions around restorations. This study investigated the effect of thermocycling on microleakage of 2 selected nanohybrid composite Class I restorations in human molars. After every 2000 thermocycles (till 20000 thermocycles) specimens were examined by stereomicroscopy using a dye penetration test. The marginal gap was measured using image analysis software. As a result the length of marginal gaps in dependence of number of thermocycles was presented. Increasing of marginal gap may be described by 3rddegree polynomial line and the velocity of marginal gap growth depends especially on adhesive system, and also on interactions between materials, physical properties of the tissue interface and the influence of the oral environment.
PL
W pracy badano wpływ cyklicznych obciążeń cieplnych na rozwój szczeliny brzeżnej dla 2 nanohybrydowych i 2 mikrohybrydowych materiałów kompozytowych w wypełnieniach klasy I w ludzkich zębach trzonowych. Próbki były oceniane na mikroskopie stereoskopowym stosując metodę penetrantu. Pomiarów długości szczeliny brzeżnej dokonano z wykorzystaniem systemu analizy obrazu. Mikroprzeciek oceniano na przekrojach wykonanych w kierunku policzkowo–językowym a następnie mezjo-dystalnym poprzez środek wypełnienia, wykorzystując 4-punktowy system oceny. Przedstawiono wyniki szczelności brzeżnej oraz ocenę punktową mikroprzecieku. Zmęczenie cieplne istotnie zwiększa mikroprzeciek w wypełnieniach klasy I, niezależnie od rodzaju kompozytu. Rodzaj kompozytu nie miał również wpływu na szczelność brzeżną.
EN
Microleakage is a major factor contributing to the occurrence of secondary carious lesions around restorations. This study investigated the effect of thermocycling on microleakage of 2 nanohybrid and 2 microhybrid composites Class I restorations in human molars. Specimens were examined by stereomicroscopy using a dye penetration test. The marginal gap was measured using image analysis software before and after thermocycling. Microleakage was evaluated on cross section in a buccolingual direction and then in a mesiodistall direction through the center of the restoration, using the 4-point scoring system. As a result the marginal integrity and microleakage scores were presented. Thermocycling significantly increased the microleakage of Class I composite restorations, independently of composite type. Composite type did not directly determine marginal integrity and microleakage as well.
PL
W pracy przedstawiono przegląd literatury dotyczący zmęczenia cieplnego zębów, jako podstawę do opracowania koncepcji badań. Na bazie analizy temperatur mierzonych w jamie ustnej oraz czasu ich oddziaływania na zęby opracowano warunki pracy stanowiska badawczego. W wyniku realizacji projektu zbudowano stanowisko oraz wykonano badania testowe. Przedstawiono zmiany temperatury wody w naczynku pomiarowym oraz w zębie, w którym umieszczono termoparę. Ponadto przedstawiono wyniki wstępnych badań zmęczenia cieplnego zębów z wypełnieniami.
EN
In this paper a short literature review of thermal fatigue as a basis for thermocycling research was presented. On the analysis the higher and the lower temperatures measured in oral cavity and time of their action the working conditions of the test stand were developed. To realize the project the test stand was constructed and tested to verify the parameters. Temperature changes in each cycle in the test cell and in tooth equipped with thermocouple were presented. Moreover preliminary results of thermocycling there were presented.
PL
W pracy wykazano, że ukierunkowana cykliczna obróbka termiczna w przedziale od kriogenicznych do wysokich temperatur pozwala w sposób zauważalny zmienić strukturę i mechanizm zniszczenia poliamidowych kompozytów z dodatkiem nanocząstek i nanorurek węglowych.
EN
It is exhibited, that directed thermocycling from cryogenic temperature up to heats allows to change noticeably structure and the mechanism of destruction of polyamide composites, filled with carbon nanoparticles and nanotubes.
EN
It is known that long term service of installations in energy and refinery industry in conditions of simultaneous action of loading and corrosion-hydrogen environments causes degradation of structural steels. This process of degradation is the most intensive on grain boundaries. Therefore structures with clad metal, namely, refinery shell, should be especially sensitive to degradation process. Three types of clad metal "low alloy steel/stainless steel" were studied: 15HM/304L, 516GR60/410S and 5l6GR70/N201. In-service degradation was modeled by thermocycling of specimens in the range of 25-550 st.C in hy-drogen atmosphere with fast rate of cooling. It allows to fix at law temperature such amount hydrogen in metal which is in equilibrium at high temperature and this is the reason of the intensive hydrogen degradation. Metal was tested after 30 and 100 thermocycles. Sensitiveness to hydrogen degradation was evaluated by slow strain rate tension of specimens during moderate cathodic polarisation. Same peculiarities of hydrogen cracking of clad metal were established and it was revealed that thermocycling in hydrogen atmosphere increases sensitivity of clad metals to hydrogen degradation. The degradation level depends on the type of clad metal and number of thermocycling.
first rewind previous Strona / 1 next fast forward last