Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  thermal mass
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Over the past 50 years the use of air conditioning in non-domestic buildings has become a norm and an indicator of status. Today the rediscovering of the natural ventilation is a part of rediscovering the buildings’ energy efficiency, or maybe even a part of a wider approach, which is a desire to be closer to nature. The main task of all ventilation systems is to maintain an appropriate indoor air quality and to improve the indoor environment. Natural ventilation systems could do the above using less energy than mechanical systems. However, it requires also the implementation of other passive measures. The most important of them are: the reduction of the harmful air contaminants, the control of heat gains, the exposition of the building’s thermal mass and utilisation of the night cooling. Because of energy efficiency and thermal comfort reasons, in temperate climate ventilation systems have to work according to at least three scenarios: spring/autumn, winter and summer. The thermal comfort parameters in naturally ventilated buildings are usually more variable than in air-conditioned ones, what does not mean that the occupants will experience thermal discomfort. Therefore, thermal comfort in passively ventilated buildings should be evaluated according to the adaptive comfort standard, appropriated for the naturally ventilated buildings. The natural ventilation has its limits and probably not all buildings can be ventilated naturally. From the energy efficiency and thermal comfort reasons, implementing the mixed mode systems is sometimes more feasible. However, the real reason why the full potential of natural ventilation could not be explored is very often the lack of confidence in relying exclusively on it.
2
Content available remote Naturalne przewietrzanie i komfort termiczny w budynkach użyteczności publiczne
EN
System wentylacji ma wpływ zarówno na występującą w budynku jakość powietrza, jak i na panujący w nim komfort termiczny. Jakość powietrza i klimat wewnętrzny oddziaływają na zdrowie i samopoczucie użytkowników budynków. Użytkownicy preferują budynki przewietrzane w sposób naturalny. Koszty eksploatacji takich budynków są niższe niż budyn - ków przewietrzanych mechanicznie, jednak ich koszty inwestycyjne mogą być większe. Budynki użyteczności publicznej mogą być przewietrzane w sposób naturalny, jednak związane jest to z wieloma ograniczeniami. Podstawową zasadą stosowaną w budynkach przewietrzanych naturalnie jest ograniczenie w nich zysków ciepła i występujących w powietrzu szkodliwych substancji oraz stosowanie materiałów i konstrukcji o dużej pojemności cieplnej i higroskopijnych. W budynkach przewietrzanych naturalnie, nie zawsze jest możliwe zachowanie stałej temperatury i innych parametrów powietrza, dlatego raczej nie jest możliwe stosowanie jej w budynkach i jego częściach, w których parametry te muszą być zachowane w sposób ciągły. Przewietrzanie naturalne wymaga zastosowania tzn. „adaptacyjnego modelu komfortu termicz - nego”, który uwzględnia warunki panujące na zewnątrz i adaptację użytkowników. W klimacie umiarkowanym systemy wen - tylacji w budynkach efektywnych energetycznie, muszą pracować, co najmniej w trzech scenariuszach: wiosenno-jesiennym, zimowym i letnim. Systemy wentylacji naturalnej najlepiej funkcjonują w okresach przejściowych. Rozwiązania stosowane zimą, muszą uwzględniać ryzyko strat ciepła powodowanych przez nawiewane zimne powietrze. Natomiast latem problemem może być zapewnienie ciągłości działania systemu wentylacji naturalnej i ochrony budynku przed przegrzewaniem się. Ze scenariuszem letnim związane są systemy nocnego chłodzenia, których skuteczność zależy od ograniczenia zysków ciepła występujących w budynku, jego pojemności cieplnej oraz temperatury nocnego powietrza. Budynek przewietrzany naturalnie wymaga zastosowania rozwiązań przestrzennych, konstrukcyjnych i funkcjonalnych, które nie mogą pozostawać jedynie w gestii projektanta jednej branży. Dlatego ich projekt wymaga projektowania zinte - growanego, w którym będą brali udział projektanci wielu branż już od fazy wstępnej koncepcji. To wymaganie wraz z innymi ograniczeniami i wyższymi kosztami inwestycyjnymi powoduje, że inwestorzy często decydują się jednak na systemy me - chaniczne lub hybrydowe.
PL
Indoor air quality and building’s thermal comfort depend very much on a ventilation system. At the same time they have an influence on health and well- being of users of buildings. The users prefer the natural ventilated spaces. The running costs of naturally ventilated buildings are smaller than the running costs of mechanically ventilated buildings. How - ever, the construction costs of the naturally ventilated buildings could be bigger. Public buildings could be ventilated nat - urally, but the natural ventilation has its limits. The main rule for designing the natural ventilated spaces is to minimize the heats gains and indoor air pollution, and to expose the hygroscopic building’s components and the components with the high thermal capacity. The temperature and the other air quality components would be more variable in naturally ventilated buildings than in air conditioned buildings. This is the reason, why the natural ventilation rather cannot be used in the buildings and the buildings parts, where the indoor climate parameters have to be constant. The thermal comfort in the naturally ventilated buildings should be assessed by the adaptive comfort model. The adaptive comfort model, relates indoor climate param - eters to the outdoor conditions, and take into account the adaptation capacity of the users. The ventilation systems in the buildings located in moderate climates has to work at least in three scenarios: spring-autumn, winter and summer. The nat - ural ventilation systems the best work in spring-autumn scenario. Winter scenario has to take into account the heat losses caused by the intake air. In summer, it could be difficult to maintain the continuity of the natural ventilation and to preserve the building from overheating. The night cooling could be used in periods of the occurring of the high outside tempera - tures. The effectiveness of the night cooling depends on the limitation of the heat loads, the building’s thermal mass and the night air temperature. The natural ventilation systems require integrated planning. From the very beginning, architects, structure engineers, HVAC designers and the other specialists should work together on the design of the naturally ventilated building. This re - quirement, the limitations of the natural ventilation and the higher construction costs are the reasons why investors oft prefer the air condition or mixed mode systems.
EN
Tertiary sector buildings and office buildings in particular are heavy users of energy and hence have the potential to make significant improvements in their energy efficiency. To achieve this there needs to be a rethinking of the building design process leading to an optimization of the building’s energy demand and good indoor environmental quality conditions. The right decisions have to be taken in the early stages of design in order to achieve the best possible energy performance of the building. The main objective of this paper is to present the results of research on the parameters that most influence the building envelope’s energy performance for Mediterranean and Oceanic climatic conditions, according to the Köppen climate classification. The study investigates how two factors-thermal mass and window-to-wall ratio-influence a building’s energy performance. A parametric study on those variables is carried out through a dynamic simulation in order to evaluate their influence for Thessaloniki, Greece, and Nicosia, Cyprus-which both feature a Mediterranean climate-and London, United Kingdom, and Munich, Germany-which both feature an Oceanic climate. The results are discussed and conclusions drawn on the influence of each parameter.
PL
Przedstawiono autorskie rozwiązania instalcji pozwalające na przygotowanie ciepła do celów c.o, c.w.u. bądź wentylacji, bazując na współpracy betonowych akumulatorów energii ze sprężarkowymi pompami ciepła.
EN
The paper presents, designed by author, schemes of installations which allow to gain low temperature energy thanks to which it is possible to prepare heat that can be efficiently used in central heating, warm water preparing and home ventilation systems. The are based on cooperation of concrete accumulators of energy with compressor heat pumps.
PL
Przedstawiono jakościową analizę wpływu pojemności cieplnej i struktury przegrody budynku na przebieg wymiany termicznej między przegrodą a pomieszczeniem na podstawie formuł całkowitych dla przepływu ciepła przez powierzchnie ściany między dwoma stanami ustalonego przewodzenia ciepła.
EN
The qualitative analysis of the influence of thermal capacity and the structure of partition of building on the course of the thermal exchange between partition and room was introduced.
7
Content available remote Wpływ struktury przegród budowlanych na ich periodyczną pojemność cieplną
PL
Pojemność cieplna elementów budynku oraz ich wewnętrzna struktura termiczna, czyli sposób ułożenia materiałów o różnej przewodności cieplnej, gęstości i cieple właściwym, mają wpływ dynamikę procesów przepływu ciepła, wywołanych oddziaływaniami czynników zewnętrznych i wewnętrznych. Dynamiczne charakterystyki cieplne przegród, które określają przebiegi procesów periodycznych, to tzw. admitancje, transmitancje i pojemności periodyczne. W niniejszej pracy rozważana jest zależność periodycznej pojemności cieplnej przegród od zależnych od struktury czynników masy termicznej.
EN
Thermal capacitance of building partitions and their internal thermal structure, that is location of materials of different thermal conductivity, density and specific heat, have an influence on dynamics of the heat transfer processes, caused by external and internal thermal excitations. Dynamic thermal characteristics of building partitions, which govern the periodic processes, are admittances, transmittances and periodic thermal capacities. In this paper, dependence of periodic capacity on the structure dependent thermal mass factors is considered.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.