Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  thermal gradient
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Numerical 3D parametric models of temperature and thermal gradient distribution within the Polish Carpathians and the Carpathian Foredeep are constructed for the interval between ground level and the 160°C isotherm. The model construction was preceded by detailed analysis of over 500 thermal logs from the area investigated and its closest vicinity. This analysis showed that the vertical changes in temperature and thermal gradient have a non-linear character with no regular pattern in the distribution of the parameters modelled, so a 3D modeling approach was chosen as the most appropriate method for their quantitative description. Furthermore, standardization of the thermal logs was recognized as mandatory so the influence of drilling process would be eliminated. Among a broad array of methods and their preconditions discussed, the Kukkonen-Szewczyk method was selected for the data collected in the study area. Modeling results show a close relationship between thermal gradient, lithology and petrophysical rock properties as well as a correlation between the distribution of positive thermal anomalies and yield of hydrocarbon accumulations within the Carpathian Foredeep. The accuracy of the model has been assessed as ~10%. The model was then used for discussion of hydrocarbon generation and prediction of formation temperature.
2
Content available remote Thermal conductivity of the gas in small space
EN
The article is devoted to research of peculiarities of porous materials with micropores thermal conductivity. The temperature influence pattern of heating surface on the process of heat transfer by convection in the pores is given. Mathematical model of gravitational convection, which allows to predict the intensity of the convection current is proposed.
EN
Effects of structural parameters on the vibration of a tapered non-homogeneous rectangular plate with different combinations of boundary conditions are discussed. Tapering in the plate is assumed to be sinusoidal in the x-direction. Here, temperature variation and non-homogeneity in the plate material are also considered sinusoidal in the x-direction. The Rayleigh-Ritz method is used to calculate the frequency parameter for the first two modes of vibration for different values of the structural parameters, i.e. the taper parameter, thermal gradient, aspect ratio and non-homogeneity constant. Results are obtained for three boundary conditions, i.e. clamped boundary (C-C-C-C), simply supported boundary (SS-SS-SS-SS) and clamped-simply supported boundary (CSS-C-SS). Numerical values of the frequency parameter are given in a compact tabular form.
4
Content available remote Non-equilibrium Computer Simulations of Coupling Effects under Thermal Gradients
EN
In this work, we discuss recent developments in the computer simulations of molecular fluids under thermal gradients. Non-equilibrium simulations allow performing numerical tests of fundamental questions of non-equilibrium thermodynamics. These tests show that non-equilibrium simulations provide an efficient approach to quantify within a single simulation the thermophysical properties of fluids along an isobar. We discuss aspects connected to the computation of local temperatures in systems under the influence of heat fluxes, and how the combination of non-equilibrium molecular dynamics and non-equilibrium thermodynamics allows understanding phenomena arising from the coupling of internal molecular variables and heat fluxes, which lead, e.g. to thermo-molecular orientation. The behavior of these orientational effects near a fluid critical point is also discussed.
5
Content available remote Wpływ rozwiązania ściany zewnętrznej na rozkłady temperatur w przegrodzie
PL
W referacie porównano rozkład temperatur w przegrodach zewnętrznych bez oraz z barierą termiczną zlokalizowanymi w II strefie klimatycznej z projektową temperaturą zewnętrzną wynoszącą -18°C oraz temperaturą wewnętrzną w pomieszczeniu równą 20°C. Do analiz przyjęto ścianę zewnętrzną o konstrukcji betonowej zaizolowa ną z obu stron styropianem. W przypadku przegrody z barierą termiczną, utworzono barierę za pomocą polipropylenowych przewodów wypełnionych niskotemperaturowym czynnikiem zawartych centralnie w warstwie betonu. W obliczeniach wariantowano temperaturę otoczenia zewnętrznego oraz temperaturę bariery termicznej, przy czym temperaturę wewnętrzną w pomieszczeniu latem przyjęto równą 24°C, a w pozostałych miesiącach 20°C. Do symulacji przepływu ciepła w przegrodzie posłużono się jedną z metod numerycznych, metodą bilansów elementarnych, która opiera się na podziale rozpatrywanego elementu na podobszary i określeniu temperatur na końcu kroku czasowego. Zastosowaną metodę opisano krok po kroku, prezentując jednocześnie tok obliczeń dotyczących analizowanych wariantów. Równania temperatur w komórkach bilansowych dla odpowiednich warunków brzegowych zestawiono w formie tabelarycznej. Wspomagająco posłużono się modelem utworzonym w programie MS Excel, dla którego wykonano obliczenia iteracyjne z krokiem czasowym równym 5 s. Otrzymane rezultaty zaprezentowano w postaci rozkładu temperatury. Na ich podstawie stwierdzono np. w warunkach obliczeniowych przesunięcie izotermy 0°C w kierunku środowiska zewnętrznego oraz większą temperaturę w pomieszczeniu na powierzchni przegrody dla rozwiązania z barierą termiczną w porównaniu do wariantu klasycznego. Czynniki te wpływają na zmniejszenie ryzyka wystąpienia wykroplenia wewnątrz przegrody oraz odczucia nagłego spadku temperatury w pobliżu ścian zewnętrznych, a także podwyższenia temperatury odczuwalnej w pomieszczeniu.
EN
The paper shows the distribution of thermal gradient in the external walls with the thermal barrier and without the thermal barrier. The walls construction are made with the concrete and the polystyrene on the both sides. The thermal barrier are the polipropylene tubes filled by the low temperature medium. The calculations are prepared for two variants. One of them used the external temperature equals -18°C (the II climatic zone), the internal temperature in a room equals 20°C and the temperature of the thermal barrier equals to 18°C. The second used the internal temperature in a room equals 24°C (in summer), 20°C (in others months) and the mean monthly temperature. For the purpose to simulate the heat transfer in the wall are used one of the numerical methods, by elemental balances, which is based on a division of the element into sub-areas and determining the temperature at the end of the time step. To support the calculations it was prepared the spreadsheet in MS Excel , for which calculations were performed iteratively with a time step equal to 5 s for both walls. The results obtained are presented in the form of a thermal gradient. The isotherm 0°C was displaced towards to the external environment and the higher temperature at the surface of the wall in the room for the solutions with the thermal barrier compared to the classical variant. These factors affect the reduction of the risk of condensation inside constructions and feeling that the temperature falls near the external walls.
EN
The paper presents the procedure of determining the thermophysical properties of concrete: heat of hardening, thermal conductivity and specific heat, which is based on point temperature measurements in a cylindrical mold and the numerical solution of the inverse heat transfer problem. The procedure was tested on concrete materials made with high-calcium fly ashes. The obtained results show good agreement with the real values of individual parameters and can be used to determine the temperature field in the object of any complex shape.
PL
W pracy przedstawiono procedurę wyznacza-nia właściwości termofizycznych betonów: ciepła twardnienia, współczynnika przewodnictwa cieplnego oraz ciepła właściwego, opartą na punktowych pomiarach temperatury w formie walcowej i numerycznym rozwiązaniu zagadnienia odwrotnego przepływu ciepła. Procedurę testowano na przykładach betonu z dodatkiem popiołów lotnych wapiennych. Uzyskane rezultaty wykazują dużą zgodność z rzeczywistymi wartościami poszczególnych paramet-rów i mogą być wykorzystane do wyznaczenia pola temperatury w obiektach o dowolnym kształcie.
EN
This study focuses on TLES (Thermal Large Eddy Simulation). We study the influence of thermal boundary conditions on mean and fluctuating profiles for a turbulent bi-periodic channel with a thermal gradient. TLES simulations show that mean profiles of longitudinal velocity, transversal velocities and their fluctuations are not affected by the therm 1 boundary conditions (flux or temperature imposed at wall). Profiles of mean temperature and mean vertical velocity are slightly changed by the thermal boundary conditions. The thermal gradient at wall is stronger and temperature slope in the middle of channel is lower with imposed temperature boundary conditions. Although there are the same in the middle of the channel, temperature fluctuations profiles are very different near to the wall according to thermal boundary conditions. In fact, with flux boundary conditions, the temperature fluctuation profile is similar close to the wall than in the middle of channel; with imposed temperature boundary conditions, theses profiles tend to zero close to the wall. This result is very important for industrial process because thermal fatigue due to thermal fluctuations at wall can damage it.
EN
In article the analysis of temperature gradient of solidification in section of hypereutectic chromium cast iron model casting was introduced. On this example was presented the method (DTGA - derivative and thermal gradient analysis), which was worked out in Department of Foundry Silesian University of Technology enabling the record of indispensable data to execution of analysis the temperature gradient and its derivative after time on section of model casting. It multichanneled apparatus to registration of data was used Crystaldigraph - PC.
9
Content available remote Warunki geotermiczne Dolnego Śląska
PL
W sposób kompleksowy przedstawiono analizę parametrów termicznych: temperatury, gradientu temperatury, przewodności cieplnej i strumienia cieplnego na obszarze Dolnego Śląska. Zweryfikowano 72 pomiary temperatury w głębokich otworach wiertniczych, z czego 51 wykorzystano do obliczeń średniego gradientu temperatury i strumienia cieplnego (10 tych pomiarów wykonano w 1996 r. w monitoringowej sieci hydrogeologicznej PIG). Wykonano mapy temperatury dla głębokości: 500 m, 1000 m, 1500 m, gradientu temperatury, strumienia cieplnego. Zanotowano, że obniżony strumień cieplny i temperaturę obserwujemy między uskokiem Odry a uskokiem brzeżnym, w starych masywach metamorficznych (metamorfik kaczawski, środkowej Odry, niemczańsko-kamieniecki, kra sowiogórska). Stwierdzono, że istnieje związek między wiekiem i historią geologiczną obszaru a współczesnym strumieniem cieplnym i temperaturą - stare masywy metamorficzne wykazują znaczne obniżenie parametrów termicznych w stosunku do tła. Dla obszarów o dużej powierzchni jest to znana prawidłowość, natomiast dla rejonu o malej powierzchni i do tego mozaikowej budowie - trudno uchwytna zależność.
EN
Analysis of thermal parameters, such as temperature, thermal gradient, thermal conductivity and heat flow in the area of Lower Silesia are presented in the paper. Temperature determinations from 72 deep boreholes were verified, 51 of them were used for mean thermal gradient and heat flow calculations (among them 10 measurements were performed in 1996, for the purpose ofthis project). Basing on above data, the maps of temperature (for the depths 500, 1000, 1500 m), thermal gradient and heat flow were drawn. The correlation between the age, geological history and between the recent heat flow and temperature on the other hand was concluded. The old metamorphic massifs show low a thermal parameters in comparison to the average values for the area. Such a coincidence is a well known rule for the large geological units but for the small units such as dealt in this paper, the correlation is usually difficult to prove.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.