Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 40

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  thermal conditions
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The paper concentrates on seasonal and spatial variations of sub-daily water temperature dynamics in lowland agricultural streams. Temperature monitoring was carried out in 24 sampling sites distributed along the tributaries of the Wkra River during the hydrological year 2021. Statistical analysis of the obtained data documented the highest water temperature dynamics in the morning, from 5:00 to 9:00 CEST, while the lowest - from 14:00 to 18:00 CEST. Seasonally, greater water dynamics were noted in the winter, expressed by a coefficient of variation reaching up to 100%. Spatially, the highest dynamics occurred in sites with the lowest proportion of riparian vegetation, while the lowest dynamics was related to higher catchment area. In the winter, the minimum daily values were recorded most frequently in the morning hours, while maximum values in the afternoon. A similar pattern was observed in the summer, but with much lower dispersion of the relative frequencies. It was found that in the winter, the dominant influence on temperature dynamics was exerted in the upstream catchment area, while in the summer, a negative relationship with riparian shade was marked. The findings suggest that the presence of riparian vegetation reduces diurnal dynamics of water temperature and is simultaneously extremely important in prolonging the duration of optimum fluctuation, responsible for the proper development of poikilothermic organisms.
PL
Najnowsze światowe raporty klimatyczne pokazały, że rok 2019 był jednym z najcieplejszych w historii pomiarów. Celem opracowania było określenie cech warunków termicznych i biotermicznych wybranych regionów Dolnego Śląska w 2019 r. oraz odniesienie ich do wartości w okresie wieloletnim 1971-2019. W analizach wykorzystano dane meteorologiczne z trzech stacji IMGW-PIB (Wrocław, Kłodzko, Śnieżka), które reprezentowały różne piętra wysokościowe. Do oceny warunków biotermicznych wykorzystano wskaźnik temperatury odczuwalnej STI. Wyniki badań pokazały, że 2019 r. był najcieplejszym lub jednym z najcieplejszych w uwzględnionym wieloleciu. Jednocześnie wykazano, że w okresie 1971-2019 znacząco wzrosła temperatura powietrza oraz częstość dni upalnych i gorących, przy malejącej liczbie dni przymrozkowych i mroźnych. W zakresie warunków biotermicznych zarówno w 2019 r., jak i wieloleciu widać wyraźną różnicę pod względem kształtowania się odczuć cieplnych między stacjami niżej położonymi (Wrocław i Kłodzko) a szczytową strefą Karkonoszy (Śnieżka). Stacje położone niżej cechuje znaczna częstość dni ze stresem gorąca w okresie letnim, w szczytowej strefie Karkonoszy natomiast przez cały rok dominują odczucia z zakresu silnego stresu zimna. W 2019 roku, w porównaniu do okresu wieloletniego, byłą większa częstość dni ze stresem gorąca i warunków pogodowych o charakterze termoneutralnym. Uzyskane wyniki badań będą mogły zostać wykorzystane w ocenie potencjału rekreacyjnego regionu Dolnego Śląska.
EN
The results of the latest WMO and NOAA reports on climate show that 2019 was one of the warmest years in the history of meteorological measurements. Therefore, the aim of the paper was to evaluate thermal conditions in 2019 in the selected regions of the Lower Silesia, Poland, and compare the results to the multiannual period of 1971-2019. Additionally, analysis on bio-thermal conditions were carried out in order to examine how changes in thermal conditions affects biometeorological issues. The analysis was carried out on the basis of meteorological data for 1971-2019 from IMGW-PIB stations representing various altitude. Wrocław (120 m a.s.l.) represented the lowlands, Kłodzko (356 m a.s.l.) the lower mountain parts, while Śnieżka (1603 m a.s.l.) represented the summit zone of the Giant Mts. In case of bio-thermal conditions evaluation, subjective temperature index STI, developed on the basis of MENEX model, was used. The results showed that 2019 at the considered stations was characterized as the warmest (Wrocław, Kłodzko) or one of the warmest years (Śnieżka) in the 1971-2019 period. Furthermore, for 1971-2019, increasing and statistically important trend was noticed for mean annual air temperature and the number of heat and warm days. The rate of increase in mean air temperature was equal to 0,5°C/ decade in Wrocław, 0,3°C/decade in Kłodzko and 0,4°C/decade on Śnieżka. On the other hand, decreasing tendency was observed for annual frequency of frosty and icy days. In terms of bio-thermal conditions, ‘cool’ thermal senses were prevailing throughout the year in the lower located regions. During the summer season, higher frequency of heat stress was noticed for both 2019 and 1971-2019. In case of Śnieżka, intensive cold stress (“extremely cold”, “very cold” and “cold”) dominates during the cold season. In the warm season, ‘cool’, “comfortable” and “warm” conditions are also observed with no weather types considered as heat stress. Comparing bio-thermal conditions in 2019 to 1971- 2019, lower frequency of cold stress occurred in 2019 at each station. In the lower located regions, higher number of days with heat stress and ‘comfortable’ conditions was noticed. On Śnieżka, frequency of ‘cool’, “comfortable” and “warm” conditions increased if compared to 1971-2019. Therefore, in case of further increase in air temperature and frequency of heat and warm days, additional increase in heat stress frequency can be expected in the lower located regions. On the other hand, improvement in bio-thermal conditions can be noticed in the summit zone of the mountains because of increase in thermoneutral conditions frequency. Nevertheless, it should be emphasized that in spite of increase in air temperature, “very cold” “cold” and “cool” thermal senses should still be predominant throughout the year in the summit zone. As bio-thermal indices are often considered in evaluations of weather conditions for tourism, the results of the analysis can be used for assessment of recreational potential of the Lower Silesia.
EN
The thermal conditions of freeze-thaw processes acting on the active cliff face of the Jeziorsko Reservoir were recognised based on temperatures of surface sediments measured directly on the monitored cliff face and data from the Kalisz weather station forming part of the network of the Institute of Meteorology and Water Management –National Research Institute (IMWM-NRI) in Warsaw, Poland. In the period from 15.01 to 04.05.2020, directly on the cliff face, 77 freeze-thaw cycles were recorded over 41 freeze-thaw days (FTD), which, on average, corresponds to two cycles per day. Concurrently, in the same period only 33 FTD were recorded in the instrument shelter, which is 20% less. In addition, the outcomes corroborate the view reported in literature; namely, that on the northern hemisphere vertical cliff faces exhibiting western exposure are advantaged in terms of the development of freeze-thaw processes.
4
Content available remote Stropy i sufity grzewczo-chłodzące o dużej pojemności cieplnej
PL
Celem artykułu jest analiza wpływu stropu aktywowanego termicznie i sufitu grzewczo-chłodzącego z wypełnieniem materiałem zmiennofazowym (PCM) na temperaturę powierzchni, temperaturę powietrza wewnętrznego oraz zapotrzebowanie na energię do ogrzewania i chłodzenia w pomieszczeniu biurowym, uwzględniając pojemność cieplną przegród i systemu grzewczo-chłodzącego. Scharakteryzowano stropy aktywowane termicznie i sufity grzewczo-chłodzące z wypełnieniem materiałem zmiennofazowym. Wykonano symulacje dynamicznych oddziaływań stropu i sufitu aktywowanego termicznie na warunki termiczne w pomieszczeniu i bilans energetyczny.
EN
The aim of the article was analysis of the thermally activated building system and heating/cooling ceiling system with phase change material (PCM) impact on the surface temperature, internal air temperature and energy demand for heating and cooling in an office room, taking into account the thermal capacity of construction and system. In this article was characterized thermally activated building system and heating/cooling ceiling system with phase change material. Based on the simple hourly method, simulation of the thermally activated building system and cooling – heating ceiling system influence on thermal conditions and energy balance in the office room were carried out.
5
Content available remote Research on thermal conditions in ventilated large space building
EN
The aim of the paper was to verify whether it is possible to predict thermal indoor environment in an industrial facility, characterized by large cubature and significant heat sources using a computational fluid dynamics (CFD) technique. For this purpose, thermal imaging measurements were carried out to obtain boundary conditions, followed by numerical simulations of the airflow using the Ansys CFX software. Direct results of temperature and velocity distribution of air were analyzed for two different cases. The possibility of reducing the supply airflow rate without affecting either technology safety or thermal comfort was examined. The results of calculations can be helpful for improving the energy efficiency of the tested object by indicating the optimal operating modes for given operating conditions of the production hall.
PL
W artykule przedstawiono wyniki badań warunków termicznych występujących w złączu izolacji wodochronnej z betonem w trakcie wykonywania nawierzchni asfaltowej na obiekcie mostowym. Impulsem do prowadzenia takich badań była potrzeba opracowania nowej hydroizolacji na betonowe pomosty obiektów mostowych. Powinna ona być odporna na zjawisko pęcherzenia występujące w ostatnich latach na wielu obiektach. Badania stanowiły element projektu badawczego zrealizowanego w ramach umowy INNOTECH-K3/IN3/50/229332/NCBR/14 [4].
EN
The paper presents the results of investigations of thermal conditions occurring in the joints of waterproofing insulation with concrete during an asphalt pavement construction on a bridge object. The impulse to conduct such research stemmed from the need to develop a new waterproofing insulation for the decks of bridge objects. This should be resistant to blistering, which has arisen on many sites during recent years. This study was part of a research project carried out under contract INNOTECH-K3/IN3/50/229332/NCBR/14 [4].
PL
Celem niniejszej pracy było zbadanie związku pomiędzy temperaturą powierzchni czynnej i gleby a temperaturą powietrza w warunkach jurajskiej doliny rzecznej. W badaniach wykorzystano materiał obserwacyjny z lat 1991– 2006 pochodzący ze stacji meteorologicznej w Ojcowie. Stacja ta położona jest w południowej części Wyżyny Krakowsko-Częstochowskiej na dnie jurajskiej doliny. Obliczono średnie dobowe, miesięczne i roczne temperatury gleby oraz jej miesięczne i roczne amplitudy. Do oceny związku pomiędzy temperaturą gleby na różnych głębokościach, a temperaturą powietrza, opadami atmosferycznymi oraz pokrywą śnieżną posłużono się współczynnikiem korelacji rang Spearmana. Na podstawie przeprowadzonych badań stwierdzono, że najsilniejsze związki temperatury powietrza z temperaturą gleby występowały w okresie wiosny i jesieni. Wzrost opadów atmosferycznych wiosną i jesienią powodował osłabienie związku temperatury powietrza z temperaturą gleby. W okresie lata związki temperatury powietrza z temperaturą gleby były słabsze i statystycznie istotne tylko do głębokości 20 cm. Wykazano ponadto, że opady atmosferyczne w lecie mogą powodować wzrost temperatury gleby. Zimą, ze względu na pokrywę śnieżną, związki temperatury powietrza z temperaturą gleby były najsłabsze i w większości przypadków statystycznie nieistotne. Stwierdzono również, że różnica temperatury powierzchniowej warstwy gleby pokrytej śniegiem i gleby bez pokrywy śnieżnej zależy przede wszystkim od grubości zalegającego śniegu.
EN
The paper presents the results of research on thermal conditions of the soil and active surface. The main aim of the research was to evaluate the relation of active surface and soil temperature with air temperature. In this evaluation, data from the period 1991–2006 from meteorological stations in Ojców were used. The meteorological station is situated in the southern part of the Kraków-Częstochowa Upland in the bottom of the Jurassic valley. For all the depths, daily, monthly and annual soil temperature was calculated. To evaluate the relation between soil temperature and air temperature, precipitation and snow cover the Spearman correlation coefficients were used. The strongest relation between the air temperature and soil temperature was observed in spring and autumn. The rise in the precipitation in spring and autumn made the relation of air temperature and soil temperature weaker and in summer the relation between the air temperature and soil temperature and statistically significant only to 20 cm deep. It was also proved that the precipitation in summer may lead to higher soil temperature. In winter, because of the snow, the relation between air temperature and soil temperature was the weakest and in most cases statistically not significant. It was also found that the differences in the temperature of the surface covered with snow and the soil without any snow cover depends primarily on the snow cover thickness.
PL
Celem opracowania jest szczegółowa analiza przebiegu warunków termicznych, oraz częstości występowania inwersji temperatury w różnych piętrach wysokościowych północnych stoków Małego Skrzycznego (1211 m n.p.m.). Materiałem badawczym wykorzystanym do analizy warunków termicznych, były dane monitoringowe pochodzące z pięciu stacji pomiarowych zainstalowanych na różnych wysokościach nad poziomem morza, wzdłuż profilu wysokościowego, na zboczach o ekspozycji południowej. W ramach opracowania wyznaczono częstości występowania poszczególnych termicznych typów pogody, zjawisk inwersji temperatury, oraz opracowano mapy rozkładu przestrzennego temperatur powietrza na badanym stoku.
EN
The aim of the research paper is a detailed analysis of a course of thermal conditions and frequency of occurrence of temperature inversion on the different height above sea level of north slopes of Małe Skrzyczne (1211 m.a.s.l.). Monitoring data coming from five meteorological stations installed on different height above sea level along hypsometric profile on slopes with southern exposure were used in order to analyze the thermal conditions. Moreover, frequency of occurrence of thermal weather types, temperature inversion phenomena and maps of spatial distribution of air temperature on the studied slope were determined.
EN
The aim of the experiment presented in this paper is to assess the relationship between the height and diameter increase rate and the thermal conditions and precipitation during its growth. The experiment was carried out in the Agro- and Hydrometeorology Observatory of the Wrocław University of Environmental and Life Sciences in 2013–2015. The height and diameter measurement was made each time on the same 43 plants, randomly selected at the stage of setting up the experiment in 2012 and specially marked. Plants included in further analyses were divided into 5 classes and the classification criterion was their height in the 3rd year of cultivation. Initially, an analysis of relationships of selected morphological parameters of Scots pine was carried out, i.e. of the heights and diameters against the changing weather conditions, i.e. precipitations and air temperatures. Subsequently, an effect of the thermal conditions and the amount of precipitation on growth of Scots pine was assessed with the use of the two meteorological parameters mentioned above. These parameters were used as their accumulated sums, calculated as of the dates of biometric measurements, made at the end of each month (the last ten days of a month) in the summer half-year period. Multiple regression analysis was applied to evaluate the effect of thermal conditions and precipitation on the growth of Scots pine in both variants and the significance of the relationships under study was examined with the use of an adjusted coefficient of determination R2. The analyses and calculations indicate a close significant relationship between the height of pine trees and their diameter at the base on any measurement date. Analyses of different measurement periods indicated a decrease in significance of the relationships between the height of pine trees and their diameter at the base. A decrease in these relationships is becoming more and more pronounced with the age of the trees. Of the two weather parameters, i.e. total air temperature and total precipitation, the precipitation dominates in the relationship with the trees height and air temperature – with the trees diameter.
PL
W artykule wykonano wskaźnikową ocenę komfortu termicznego dwóch różnych budynków mieszkalnych. Wykorzystano do tego wskaźniki PMV (przewidywana ocena średnia) i PPD (przewidywany odsetek osób niezadowolonych). Badania sporządzono w oparciu o długoterminowe pomiary temperatury, prędkości i wil-gotności powietrza wewnętrznego.
EN
The article presents an indicative assessment of thermal comfort for two different residential buildings. The following indicators were used: PMV (Predicted Mean Vote) and PPD (Predicted Percentage Dissatisfied). The study was prepared on the basis of long-term measurements of temperature, velocity and humidity of indoor air.
11
Content available Warunki termiczne w Centrum Bielska-Białej
PL
Na terenach miejskich temperatura powierzchni jest wyższa niż w otaczających obszarach pozamiejskich. Zjawisko to określane jest jako miejska wyspa ciepła (m.w.c.). Efekt ten badano porównując średnie temperatury mierzone na dwóch stanowiskach w latach 2010–2013 w terenie miejskim i pozamiejskim. Systematyczne różnice temperatur wskazują na występowanie zjawiska kontrastów termicznych o różnym natężeniu w analizowanych częściach miasta, co może być częściowo związane z położeniem terenu w obszarze podgórskim.
EN
In urban areas surface temperatures are higher than in surrounding rural areas. This phenomenon is called urban heat Island (UHI). This phenomenon was investigated by the comparison of the mean temperatures from two measurement points in urban and suburban areas from 2010 to 2013. The observed systematic temperature differences validate the occurrence of UHI of diverse intensities in different parts of the urban area which can be partially connected with the foothills location of the city.
PL
W artykule przedstawiono wyniki badań eksperymentalnych przegród zawierających materiały fazowo zmienne (PCM). Przedmiotem badań było jednoczesne zastosowanie dwóch rodzajów PCM: płyt gipsowo-kartonowych zawierających kapsułki z parafiną o temperaturze przemiany 23 °C oraz elastycznych mat wypełnionych materiałem organicznym o temperaturze przemiany 25 °C. Badania przeprowadzono w komorze klimatycznej. Analizowano pomiary przebiegu temperatury oraz rozkładu gęstości strumieni cieplnych na powierzchniach płyt w zmiennych warunkach panujących w komorze klimatycznej.
EN
The article presents results of experimental studies on component containing phase change materials (PCM). The subject of research was the simultaneous usage of two different PCM materials: gypsum-carton boards with paraffin capsules of change temperature 23 °C and the flexible mat filled with organic material of change temperature 25 °C. The tests were carried out in a climatic chamber. Measurements of temperature course were taken as well as heat flux density distribution on the surfaces of boards for variable conditions in the climatic chamber.
EN
The research was carried out in a mesotrophic and dimictic lake during winters with ice cover. In the last forty years, the development of phytoplankton was analyzed in five extreme winter seasons. The studies of phytoplankton characteristics in the water column took into account values of biomass, concentration of chlorophyll-a and species composition, including dominant species. Differences in the vertical distribution of flagellate and non-flagellate species belonging to cyanobacteria and algae were analyzed in the gradient of light and thermal conditions. The phytoplankton biomass was low and vertically differentiated, with the lowest values at the deeper part of the water column. Flagellate species from the group of Cryptophyceae, Chrysophyceae and Dinophyceae were most abundant. Species biodiversity was low but every winter the dominant species represented different taxonomic groups. In some periods, larger non-motile phytoplankton species from green or blue-green algae dominated. The research proved that the development of phytoplankton under the ice cover was limited mainly by light and, to a lesser extent, by temperature.
PL
Na bezpieczeństwo i wydajność pracy górników w znaczący sposób wpływają cieplne warunki pracy. Głównym czynnikiem decydującym o poziomie zagrożenia cieplnego jest rosnąca wraz z głębokością temperatura pierwotna skał. Wynikająca z tego wysoka temperatura powietrza w połączeniu ze znaczną wilgotnością negatywnie wpływa na warunki pracy górników w wyrobiskach podziemnych kopalń węgla kamiennego oraz rud miedzi. Coraz częściej konieczne jest wprowadzanie skróconego czasu pracy lub stosowanie środków służących poprawie warunków cieplnych w wyrobiskach. W polskim górnictwie obowiązują kryteria prawne regulujące zasady pracy w warunkach zagrożenia cieplnego.
EN
This paper reports the results of computer simulations of the flow of liquid steel in a single-nozzle tundish, which describe the flow hydrodynamics, depending on the thermal conditions and casting speed. In this paper, five casting speeds, namely 0.3, 0.6, 0.9, 1.2 and 1.5 m/min., have been examined. In view of the fact that tundishes are being equipped with various flow control devices and the process of creating specific hydrodynamic conditions is influenced also by the temperature gradient, computer simulations of liquid steel flow under isothermal and non-isothermal conditions were performed. Computer simulations of liquid steel flow were performed using the commercial program Ansys-Fluent ®. In order to explain the phenomena occurring in the tundish working space, the buoyancy number (Bu) has been calculated. The next research step in the analysis of the flow pattern forming in different casting conditions was to record the E and F-type RTD characteristics and to describe the pattern of flow.
PL
Praca przedstawia wyniki symulacji komputerowej opisujacej wpływ warunków cieplnych i predkosci odlewania na przepływ ciekłej stali w jedno-wylewowej kadzi posredniej. W pracy testowano piec predkosci odlewania: 0,3; 0,6; 0,9; 1,2 i 1,5 m/min. Ze wzgledu na gradient temperatury powstajacy w objetosci ciekłej stali i stosowanie w kadziach posrednich urzadzen sterujacych przepływem, symulacje komputerowa przepływu ciekłej stali wykonano dla warunków izotermicznych i nieizotermicznych. Symulacje komputerowa przepływu ciekłej stali wykonano za pomoca programu Ansys-Fluent ®. Dla wyjasnienia zjawisk wystepujacych w przestrzeni roboczej kadzi posredniej obliczono liczbe wyporu (Bu). Do analizy struktury hydrodynamicznej przepływu ciekłej stali w róznych warunkach odlewania zarejestrowano krzywe czasu przebywania typu E i F.
PL
Zaprezentowano ocenę warunków cieplnych oraz jakości powietrza wewnętrznego w budynku szkoły podstawowej. Przeanalizowano skuteczność wentylacji, warunki cieplne oraz poziom stężenia CO2 w wybranych pomieszczeniach budynku.
EN
The paper presents an estimation of thermal conditions and indoor air quality in a primary school building. The efficiency of ventilation, thermal conditions and CO2 concentration level have been analysed in selected rooms of the building
17
Content available remote Parametry powietrza w suchym odpylaczu filtracyjnym
PL
W artykule dokonano oceny szczelności pracującej instalacji odpylającej z suchym odpylaczem typu HBKM 1/400 oraz określono jego wpływ na temperaturę i wilgotność przepływającego powietrza. Znajomość tych wielkości ma istotne znaczenie dla prawidłowego określenia rozkładu temperatury i wilgotności powietrza w wyrobiskach korytarzowych przewietrzanych kombinowaną wentylacją lutniową, w której w pomocniczym lutniociągu zabudowany jest ten typ odpylacza. W formie tabelarycznej przedstawiono wyniki przeprowadzonych w warunkach in situ pomiarów parametrów termodynamicznych przepływającego rozważaną instalacją powietrza. Wykonano analizę statystyczną bezwzględnych i względnych odchyłek wilgotności właściwej oraz wydatku objętościowego powietrza w instalacji odpylającej. Wyznaczono również średni przyrost temperatury powietrza w przedmiotowej instalacji.
EN
In the present article the tightness of a working dust extracting installation equipped with a dry filter dust collector of the HBKM 1/400 type is assessed and the filter’s influence on the temperature and humidity of flowing air through the installation is determined. The knowledge of these quantities is highly important for the appropriate determination of the distribution of air temperature and humidity in roadway workings ventilated by means of combined air duct ventilation, where in the auxiliary air duct this type of dust collector is installed. The results of measurements of thermodynamic parameters of air flowing through the considered installation conducted under in situ conditions are presented in the tabular form. The statistic analysis of absolute and relative deviatons of the specific humidity as well as volumetric expenditure of air in the dust extracting installation has been performed. Moreover, the average air temperature increase in the installation has been determined.
18
Content available remote Optimisation of Thermal Conditions in a Composite Wet Diving Suit
EN
The main goal was to optimise the thermal conditions within a diving suit and improve the user’s comfort. The wet diving suit consisted of (i) an external neoprene layer with air bubbles as additional insulation, and (ii) internal textile clothing to improve the insulation effect. Both layers were connected as a composite because the friction coefficient is very high. The core temperature should be constant and monitored during activity because a change in it is a sign of hypothermia. The internal textile layer contained textronic systems to transfer the medical parameters selected. The state variable is the temperature, whereas the design variables are the coordinates of the crucial points within the layers. Heat transfer is described by a state equation and set of boundary and initial conditions. The first-order sensitivities of an arbitrary behavioural functional are formulated and implemented into the optimality conditions of the problem. A simple numerical example of the optimisation of the thermal conditions is considered.
PL
Główny cel to optymalizacja warunków termicznych w ubiorze do nurkowania oraz polepszenie komfortu jego użytkownika. Mokry ubiór do nurkowania składa się z (i) zewnętrznej warstwy neoprenu z pęcherzykami powietrza jako dodatkową izolacją cieplną, (ii) wewnętrznego ubioru włókienniczego do polepszenia efektu izolacji cieplnej. Obie warstwy są połączone na zasadzie kompozytu, ponieważ współczynnik tarcia miedzy nimi jest bardzo duży. Temperatura ciała powinna być stała i monitorowana podczas aktywności, jej zmiana może być sygnałem hipotermii. Wewnętrzna warstwa materiału włókienniczego zawiera systemy tekstroniczne do transportu wybranych parametrów medycznych. Zmienna stanu to temperatura, zaś zmienne projektowania to współrzędne podstawowych punktów w każdej warstwie. Przewodzenie ciepła jest opisane za pomocą równania stanu oraz układu warunków brzegowych początkowych. Zostały sformułowane wrażliwości pierwszego rzędu dla dowolnego funkcjonału w postaci ogólnej, które dalej wprowadzono do warunków optymalności problemu. Został rozwiązany prosty przykład numeryczny optymalizacji warunków termicznych.
PL
Bardzo ważnym elementem systemów zasilania gwarantowanego jest zasobnik energii, którym najczęściej jest bateria akumulatorów kwasowo-ołowiowych. Producenci zalecają dla akumulatorów pracę w zakresie temperatur 15÷25°C. Aby zapewnić takie warunki, konieczne jest klimatyzowane pomieszczenie. Kiedy ze względów ekonomicznych nie ma klimatyzacji lub z powodu awarii klimatyzacja nie działa, bateria akumulatorów jest narażona na pracę w skrajnych warunkach temperaturowych.
PL
Opracowano charakterystyki energetyczne z przedstawieniem wskaźników zapotrzebowania na energię użytkową, końcową i pierwotną. Porównano otrzymane wyniki z wartościami referencyjnymi, tj. wariantem bazowym WT, maksymalnym WM i maksymalnie technicznym możliwym do wykonania z wentylacją mechaniczną z odzyskiem ciepła WMO. Przedstawiono wyniki badań parametrów środowiska wewnętrznego w pomieszczeniach biurowych w budynku tradycyjnym i energooszczędnym, które wykazują zgodność z rezultatami obliczeń emisji ditlenku węgla w warunkach rzeczywistych.
EN
In the paper energy characteristics and consumption indicators for usable final and primary energy have been determined. The results were compared with reference values, i.e. base variant WT, the maximum WM and maximum technically possible to implement with mechanical ventilation and heat recovery WMO. The paper presents also the investigation results of the internal environment in offices for the traditional and energy-efficient buildings which demonstrate compatibility with the results of calculations of carbon dioxide emissions in real conditions.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.