EN
This paper aims to discuss the behavior of the proprietary real-time simulator (RTS) during testing the coordination of distance relay protections in power engineering. During the construction process of the simulator, the mapping of various dynamic phenomena occurring in the modeled part of the power system was considered. The main advantage to the solution is a lower cost of construction while maintaining high values of essential parameters, based on the generally available software environment (MATLAB/Simulink). The obtained results are discussed in detail. This paper is important from the point of view of the cost-effectiveness of design procedures, especially in power systems exploitation and when avoiding faults that result from the selection of protection relay devices, electrical devices, system operations, and optimization of operating conditions. The manuscript thoroughly discusses the hardware configuration and sample results, so that the presented real-time simulator can be reproduced by another researcher.
EN
Real time simulators of IEC 61850 compliant protection devices can be implemented without their analogue part, reducing costs and increasing versatility. Implementation of Sampled Values (SV) and GOOSE interfaces to Matlab/Simulink allows for interaction with protection relays in closed loop during power system simulation. Properly configured and synchronized Linux system with Real Time (RT) patch, can be used as a low latency run time environment for Matlab/Simulink generated model. The number of overruns during model execution using proposed SV and GOOSE interfaces with 50 µs step size is minimal. The paper discusses the implementation details and time synchronization methods of IEC 61850 real time simulator implemented in Matlab/Simulink that is built on top of run time environment shown in authors preliminary works and is the further development of them. Correct operation of the proposed solution is evaluated during the hardware-in-the-loop testing of ABB REL670 relay.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.