Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  termika
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A highs ignifance of the Kutno 2 deep borehole is due to its location in the central zone of the Polish Basin where the Rotliegend complex has previously never been achieved by other drill holes and thus was not recognized and studied. Drill core from the Rotligend of the Kutno2 has been recently studied for its petrography and facies. The Rotligend in this zone is represented by fluvial and alluvial sediments. It is composed mainly of fine- to coarse-grained sandstones, with conglomerate inter beds. Diagenetic processes of the sediments have been dominated by mechanical and chemical compaction, as well as by transformation of the unstable mineral components. Fluid inclusion analysis for quartz and carbonates indicates that the diagenesis-associated temperature reached 120-180°C. The presence of haematite pseudomorphoses after framboidal pyrite indicates an extremely high palaeotemperature of approx. 500°C. Itis related here to the Jurassic hydrothermal event. The recent very high reservoir pressure might be associated with high temperatures due to the aqua thermal pressure mechanism.
2
Content available remote Tarasy nadziemne–projektowanie i warunki techniczne wykonania
PL
W artykule autor omawia kwestie związane z projektowaniem tarasów, doborem właściwych rozwiązań w zakresie materiałów i technologii stosowanych w tego typu konstrukcjach. W ramach tej publikacji szczegółowo omówiono kwestie doboru izolacji w zakresie termiki, akustyki i ochrony przed wilgocią.
EN
In the article, the author discusses issues related to the design of terraces, the selection of appropriate solutions in the field of materials and technologies used in this type of structures. This publication includes a detailed description of the selection of insulation in terms of thermal properties, acoustics and protection against moisture.
PL
W artykule przedstawiono analizę termiczną rozdzielnicy nN zawierającą moduł z wyłącznikiem głównym. Zaprezentowano podejście do analizy sprzężonej składającej się z dwóch etapów tj. wyznaczenia strat przy wykorzystaniu analizy elektromagnetycznej, a następnie przeniesieniu ich do analizy CFD. Obliczone straty ciepła Joule’a (szynoprzewody miedziane, straty indukowane w obudowie) wykorzystano jako dane wejściowe do analizy termicznej, która zawiera rozwiązanie promieniowania oraz konwekcji naturalnej. Wyniki otrzymane w symulacji numerycznej porównano z rzeczywistym testem termicznym wykonanym w laboratorium Rockwell Automation zgodnie z normą IEC 61439-1.
EN
Paper presents thermal analysis of low voltage motor control center column which contain the main unit with air circuit breaker. Described is two-stage simulation approach which includes electromagnetic and CFD analysis coupled together. The output of electromagnetic simulation is heat loss generated as the results of Joule heating and induction of eddy current on sheet metal parts of the enclosure. Heat loss in an input for further CFD simulation. CFD simulation is used to calculate radiation and natural convection. Results of performed simulation were compared to the real thermal test rain in Rockwell Automation laboratory according to IEC 61439-1 standard.
PL
W artykule przedstawiono analizę termiczną rozdzielnicy niskiego napięcia zawierającą moduł z wyłącznikiem głównym. Zaprezentowano podejście do analizy sprężonej składającej się z dwóch etapów, tj. wyznaczenia strat przy wykorzystaniu analizy elektromagnetycznej i przeniesieniu ich do analizy CFD. Na etapie analizy elektromagnetycznej obliczono straty ciepła Joule'a, jako wynik grzania rezystancyjnego w przewodnikach miedzianych oraz ciepła wyindukowanego na elementach stalowych obudowy (prądy wirowe). Analiza elektromagnetyczna uwzględnia również zjawisko naskórkowości oraz efekt zbliżenia pomiędzy przewodnikami różnych faz. Straty ciepła wykorzystane są jako dane wejściowe do analizy termicznej, która zawiera rozwiązanie promieniowania i konwekcji naturalnej. Wyniki otrzymane w symulacji numerycznej porównano z rzeczywistym testem termicznym wykonanym w laboratorium firmy Rockwell Automation zgodnie z normą IEC 61439-1.
EN
Paper presents thermal analysis of low voltage motor control center column which contains main unit with air circuit breaker. Described is two-stage simulation approach which includes solution of electromagnetic field and CFD analysis coupled together. The result of electromagnetic simulation, which is the first step of this combined approach, is heat loss generated as the result of Joule heating and induction of eddy currents on sheet metal parts of the enclosure. Heat loss is an input for further CFD simulation which is the final stage of analysis. CFD simulation is used to calculate radiation and natural convection. Results of conducted simulation were compared to real thermal test ran in Rockwell Automation laboratory according to IEC 61439-1 standard.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.