Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  tendon
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: The aim of the study was to investigate the viscoelastic response in the low and high physiological strain with the use of experimental and modeling approach. Methods: Viscoelastic response in the low, transition and high physiologic strain (3, 6 and 9%) with consideration of simulated biological environment (0.9% saline solution, 37 °C) was measured in relaxation tests. Preconditioning of tendons was considered in the testing protocol and the applied range of load was obtained from tensile testing. The quasi-linear viscoelasticity theory was used to fit experimental data to obtain constants (moduli and times of relaxation), which can be used for description of the viscoelastic behavior of tendons. The exponential non-linear elastic representation of the stress response in ramp strain was also estimated. Results: Differences between stress relaxation process can be seen between tendons stretched to the physiological strain range (3%) and exceeding this range (6 and 9%). The strains of 6% and 9% showed a similar stress relaxation trend displaying relatively rapid relaxation for the first 70 seconds, whereas the lowest strain of 3% displayed relatively slow relaxation. Conclusions: Results of the model fitting showed that the quasi-linear viscoelastic model gives the best fit in the range of low physiological strain level.
PL
Scharakteryzowano metody nieniszczące najczęściej stosowane do kontroli stanu kabli podwieszających i sprężających mosty. Przedstawiono metody preferowane do wykrywania defektów cięgien kabli podwieszających oraz kabli zewnętrznych i wewnętrznych kablobetonowych dźwigarów mostowych. Omówiono zakresy przydatności tych metod w praktyce.
EN
The NDT methods most often used to control condition of tendons of these bridges have been characterized. Presented methods are preferable for the detection of defects in the strands of stay cables as well as external and inside cables of PT bridge girders. The range of usefulness of these methods in practice is discussed.
PL
W pracy przedstawiono wyniki badań doświadczalnych przeprowadzonych na ścięgnach przednich kończyn świńskich. Badania przeprowadzono przy użyciu maszyny wytrzymałościowej MTS Insight. W ramach badań wyznaczono wartości modułu Younga, naprężeń oraz odkształceń ścięgien palców przednich jako preparatów do zastosowań ksenogenicznych.
EN
In this paper it was presented the results of experimental investigations, performed on the swine tendons samples dissected from anterior limbs. The main aim of investigations was to determine the mechanical properties of swine tendons for xenogenic applications. The tests were carried out with the use of MTS Insight static machine. It was determined the Young's modulus values and also the stress and strains of tendons that occurs during the static tensile test.
PL
W artykule przedstawiono metodykę oraz parametry prób rozciągania stali, takie jak prędkość przyrostu obciążenia, prędkość odkształcenia, punkty wyznaczania modułu sprężystości. Uzyskane wyniki prób rozciągania przypisano poszczególnym producentom splotów. Analizę statystyczną rozrzutu wartości przeprowadzono osobno dla poszczególnych własności mechanicznych. Jako kryterium odniesienia przyjęto wymagania aprobat technicznych. Przeprowadzono również analizę schematu zniszczenia.
EN
The methodology and parameters of tensile tests of steel e.g. velocity of the load increase, strain velocity and the points determining of elastic modulus were presented in paper. The obtained results of tensile test were assigned to the individual producers of steel stands. Statistical analysis of the scatter of obtained values was carried out separately for mechanical properties. As benchmarks the requirements of Technical Approval were adopted. The analysis of the failure mode was also made.
PL
W przypadkach stanów awaryjnych silosów i zbiorników żelbetowych często używaną metodą jest wzmacnianie obwodowe za pomocą cięgien lub prętów sprężających. Metody wzmacniania stosowane wcześniej zastąpiono nowymi technologiami o większej skuteczności i trwałości. Wprowadzone zostały nowe systemy kotwienia i nowe zabezpieczenia cięgien sprężających, a także nowe materiały do sprężania konstrukcji. W artykule przedstawiono aktualne kierunki rozwojowe omawianych technologii. Istota zmian polega m.in. na możliwości zastosowania cięgien odpornych na korozję, z kontrolowaną przyczepnością, na zastosowaniu zakotwień zblokowanych oraz na optymalizacji geometrycznej tras cięgien sprężających w strefie zakotwienia.
EN
Circumferential strengthening of RC or PC tanks and silos by using prestressing tendons or bars is a frequently used method. The hitherto methods were replaced by new technologies of increased efficiency and durability. There were introduced new systems and new methods of protection of prestressing tendons, as well as new materials for the prestressing of structures. The author of the paper had taken part in the implementation of these new technologies in Poland. The paper presents the current directions of development of the technologies involved. The essence of the changes is, inter alia, the application of corrosion resistant tendon, with the controlled bond, the use of interlocked anchores and geometric optimization of tendons routes in the anchorage zone.
PL
W artykule przedstawiono szereg przykładów ilustrujących różne przypadki diagnostyczne. W wielu z nich występują (lub występowały) stany zagrożeń silosów sprężonych obwodowo spowodowane korozją cięgien. Obecnie dysponujemy metodami skutecznego i trwałego wzmacniania tego typu konstrukcji. Z analizy wyników monitorowaniu tych konstrukcji wynikają istotne wnioski odnośnie wymagań w zakresie projektowania, wykonawstwa, diagnostyki i eksploatacji omawianych obiektów.
EN
The article lists numerous examples which illustrate various diagnostic cases. In case of many of them, there is (or was) the risk to the silos as a result of the corrosion of the bands. Nowadays, we may use methods of efficient and durable reinforcement in this kind of constructions. The analysis of the results of monitoring the constructions provides significant conclusions regarding the design, performance, diagnostics and use of the said objects.
7
Content available remote Stalowe konstrukcje cięgnowe. Cz.3 Obliczenia statyczne
8
Content available remote Stalowe konstrukcje cięgnowe. Cz.1 Charakterystyka
9
Content available remote Badania nośności splotów typu Y1860-S7 w zakotwieniach szczękowych
EN
In the paper selected topics concerning the load-bearing capacity of seven wires splices using in a production of pre-tensioned prestressed concrete elements were presented. On the basis of the own investigations on load-bearing capacity of tension member – anchorage systems and the analysis of anchorages information a few conclusions and guides concerning safety of string tension during production of pre-tensioned prestressed concrete girders were defined.
EN
FT-Raman spectroscopy was used to investigate microstructural changes in the secondary protein structure of soft tissues subjected to increasing levels of macroscopic strain. Main protein bands at 938 cm-1 assigned as v(Cα–C), 1668 cm-1 — amide I and 1268 cm-1 — amide III are sensitive to applied strain and undergo wavenumber shifting. Other main vibrational modes at 1004 cm-1 assigned to the phenyl ring breathing mode and 2940 cm-1 (n(CH3,CH2)) remain unaltered. Spectroscopic results were compared with the mechanical relations obtained from the standard protocol of uniaxial tensile tests carried out in a testing machine. A clear correlation between Raman band shifting and the level of mechanical stress was established. Initially the load is transferred through elastin and then gradually also by collagen. It was proved that transferring loads by soft tissues involves changes in structural protein conformation. This process was described in detail for a tendon. It was also confirmed that mechanical properties of soft tissues depend on collagen and elastin fiers orientation.
11
Content available remote Structural alteration of collagen fibres - spectroscopic and mechanical studies
EN
Fourier Transform Near Infrared Raman Spectroscopy has been used to monitor the molecular changes of collagen in a tendon subjected to strain. In the Raman spectrum of the unstrained tendon, some protein bands, mainly assigned to collagen, can be observed: amide I (1666 cm–1) and III (1266 and 1248 cm–1) vibrational modes and skeletal (C–C) stretching vibrations (816 and 940 cm–1). The position of these bands is changing with the increasing strain values. It is concluded that elastin and non-helical domains of collagen are initially involved in the load transfer and triple helices of collagen are gradually joining this process.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.