Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  temperature rise
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Temperature rise of the hub motor in distributed drive electric vehicles (DDEVs) under long-time and overload operating conditions brings parameter drift and degrades the performance of the motor. A novel online parameter identification method based on improved teaching-learning-based optimization (ITLBO) is proposed to estimate the stator resistance, 𝑑-axis inductance, 𝑞-axis inductance, and flux linkage of the hub motor with respect to temperature rise. The effect of temperature rise on the stator resistance, 𝑑-axis inductance, 𝑞-axis inductance, and magnetic flux linkage is analysed. The hub motor parameters are identified offline. The proposed ITLBO algorithm is introduced to estimate the parameters online. The Gaussian perturbation function is employed to optimize the TLBO algorithm and improve the identification speed and accuracy. The mechanisms of group learning and low-ranking elimination are established. After that, the proposed ITLBO algorithm for parameter identification is employed to identify the hub motor parameters online on the test bench. Compared with other parameter identification algorithms, both simulation and experimental results show the proposed ITLBO algorithm has rapid convergence and a higher convergence precision, by which the robustness of the algorithm is effectively verified.
2
Content available remote Temperature rises of wires discharging lightning current placed in polystyrene
EN
Results of temperature rise measurements for lightning current discharge wires placed in polystyrene are presented in the article. The tests were run using a lightning current generator. The present practice in construction is to place wires discharging lightning current in insulation tubes. The obtained test results unequivocally show that there is no hazard arising from temperature rise if the discharging wire is placed directly in polystyrene insulation.
PL
W artykule zaprezentowano wyniki pomiarów przyrostu temperatury przewodów odprowadzających prąd piorunowy umieszczonych w styropianie. Badania przeprowadzono z wykorzystaniem generatora prądu piorunowego. Dotychczasowa praktyka stosowana w budownictwie zakładała prowadzenie przewodów odprowadzających prąd piorunowy w rurkach izolacyjnych. Otrzymane wyniki pomiarów jednoznacznie wskazują na brak zagrożenia niebezpiecznym wzrostem temperatury przy bezpośrednio prowadzonym przewodzie odprowadzającym w izolacji styropianowej.
PL
W artykule zaprezentowano wyniki pomiarów przyrostu temperatury przewodów odprowadzających prąd piorunowy umieszczonych w styropianie. Badania przeprowadzono z wykorzystaniem generatora prądu piorunowego. Dotychczasowa praktyka stosowana w budownictwie zakładała prowadzenie przewodów odprowadzających prąd piorunowy w rurkach izolacyjnych. Otrzymane wyniki pomiarów jednoznacznie wskazują na brak zagrożenia niebezpiecznym wzrostem temperatury przy bezpośrednio prowadzonym przewodzie odprowadzającym w izolacji styropianowej.
EN
Results of temperature rise measurements for lightning current discharge wires placed in polystyrene are presented in the article. The tests were run using a lightning current generator. The present practice in construction is to place wires discharging lightning current in insulation tubes. The obtained test results unequivocally show that there is no hazard arising from temperature rise if the discharging wire is placed directly in polystyrene insulation.
PL
Miejsca połączeń elektrycznych są potencjalnym źródłem zagrożenia, wynikającego z trudnych warunków operacyjnych, takich jak przepływ dużych prądów, warunki środowiskowe, narażenie na wibracje połączeń skręcanych, rosnąca z czasem rezystancja styku. W artykule przedstawiono system GIT chroniący instalacje elektroenergetyczne przed skutkami wzrostu temperatury. Zaprezentowane rozwiązanie zostało zaprojektowane w celu zminimalizowania ryzyka związanego ze zwiększoną temperaturą, która może pojawić się na mostach, szynach, kablach, przepustach, izolatorach i stykach aparatury łączeniowej, a także odbiornikach i generatorach energii elektrycznej. System GIT ma na celu ciągłe monitorowanie temperatury w newralgicznych punktach instalacji elektroenergetycznej, włączając w to połączenia szyn z aparatami łączeniowymi znajdującymi się pod napięciem. Opracowane sensory przewidują możliwość pomiaru temperatury nawet w przypadku, kiedy w szynach lub mostach nie płynie prąd.
EN
Electrical connections are a potential source of hazards due to difficult operating conditions such as high currents, environmental conditions, vibration exposure to twisted connections, and contact resistance increasing over time. The article presents the GIT system protecting electrical installations against the effects of temperature rise. The presented solution is designed to minimize the risk of increased temperatures that may occur on bridges, rails, cables, culverts, insulators and contacts of the switching equipment, as well as the receivers and generators. The GIT system is designed to continuously monitor the temperature in the critical points of the power system, including the connections of contactor or breaker unit. Developed sensors can measure the temperature even in unconnected, unpowered rails or bridges.
EN
Emergency motor switch-on happens occasionally while operating a doublesquirrel- cage motor at full supply voltage with the rotor blocked (e.g., in coal mills). After releasing the blockage, the by now heated motor is started up again. However, the mechanical stress caused by the increased temperature poses considerable hazards to the squirrel-cage winding. This paper presents a double-cage induction motor model for analysis of thermal fields in transient operation. The thermal field for the rotor of a doublesquirrel- cage motor of soldered or cast structure, operating in the conditions described, has been calculated in the present paper using a thermal network method. Measurement results have been presented for the double-squirrel-cage winding temperature for a soldered cage construction in the blocked rotor state.
PL
W artykule przedstawiono zagadnienia związane ze spadkami napięcia występującymi w instalacjach elektrycznych. Szczególną uwagę zwrócono na różnice w wartościach spadków napięć występujących w rzeczywistych obwodach elektrycznych od tych wyznaczonych teoretycznie. Wskazano również wartość współczynnika poprawkowego uwzględniającego termiczny wzrost rezystancji, rzeczywisty przekrój przewodu oraz rezystancje pasożytnicze wprowadzane przez połączenia montażowe obwodu elektrycznego.
EN
The article presents the issues related to the voltage drop occurring in the electric system, especially the differences in the values of voltage drops occurring in the electrical circuits and theoretical circuits.
PL
Materiały funkcjonalnie gradientowe (FGM), po raz pierwszy wprowadzone w 1984 r., stały się bardzo popularne w badaniach naukowych i zastosowaniach inżynierskich. Typowy FGM jest dwufazowym (zwykle metal-ceramika), heterogenicznym kompozytem, których wzajemna zawartość zmienia się w sposób ciągły. Wysoka odporność na temperatury (ceramika) i dobre właściwości mechaniczne (metal) sprawiają, że konstrukcje wykonane z FGM są stosowane jako osłony w otoczeniu wysokich temperatur. Wyboczenie FG płyt pod wpływem ustalonych w czasie obciążeń cieplnych było, w ostatnich kilku latach, przedmiotem wielu prac. Problem dynamicznego wyboczenia cienkościennych, gradientowych konstrukcji poddanych impulsowemu przyrostowi temperatury wydaje się być ważny inżynierskiego punktu widzenia.
PL
Przedstawiono analizę wpływu zmiany przyrostu temperatury przewodów na ich dobór na pracę długotrwałą, zwarciową oraz straty energii elektrycznej.
EN
The paper presents analysis of influence of temperature rise of conductors on their selection for continuous operation, short-circuit operation and electric power losses.
PL
Celem badań było określenie zmian temperatury tkanek w polu zabiegowym podczas różnych zabiegów stomatologicznych z wykorzystaniem lasera. W artykule opisano metody pomiarów opracowane dla poszczególnych zabiegów oraz urządzenia do rejestracji temperatury. W badaniach zastosowano lasery stomatologiczne: laser CO2, laser Nd:YAG i laser Er:YAG. Rejestracje termograficzne wykonano za pomocą dwóch pomiarowych kamer termowizyjnych ThermaCAM SC1000 i ThermaCAM SC3000. Omówiono efekty uzyskane dzięki rejestracji powierzchniowych rozkładów temperatury podczas zabiegów, a w szczególności opracowano zalecenia zwiększające bezpieczeństwo stosowania laserów w stomatologii.
EN
The aim of the study was to determine the temperature changes of tissues in the operative area during several dental treatments involving the use of a laser. The paper presents the measurement methods specially created for that task as well as the devices used to record infrared images. During the research three kinds of laser devices were used: CO2 laser, Nd:YAG laser and Er:YAG laser. Infrared images were recorded by two measurement IR cameras: ThermaCAM SC1000 and ThermaCAM SC3000. The effects obtained by the possibility of real-time recording of surface temperature distribution during treatment were discussed and the recommendations improving the safety of use of laser devices in dental treatment were created.
EN
In the paper dependencies allowing the indication of temperature increases in the three-phase of a stator winding at intermittent work in conditions of asymmetric voltage feed are presented.
PL
W referacie zaproponowano zależności pozwalające na obliczenie przyrostów temperatuy najbardziej obciążonej prądowo fazy uzwojenia stojana trójfazowego silnika indukcyjnego przy pracy przerywanej w warunkach niesymetrii napięcia zasilającego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.