Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  temperature level
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The increasing importance of HVDC transmission systems requires the development and evaluation of suitable basic approaches regarding the partial discharge diagnosis. Although diverse promising approaches are identified, recent research is focused on standard atmospheric conditions. Due to the fact that this is just partly consistent to real operating conditions, additional research is required. Focusing on the time domain analysis of corona discharges, occurring under positive DC voltage stress in air, a measurement method for investigating the influence of varying atmospheric quantities is presented. Measurements are carried out for five different relative humidity levels in the range of 20 % to 95 % and for four different temperature levels in the range of 20°C to 65°C. As characterizing pulse shape parameters, the rise time, the pulse width and the fall time are determined as well as the apparent charge. The gained values are compared to each other and reconciled with physical processes.
PL
W artykule przedstawiono charakterystykę przebiegu procesu spalania słomy. Do tego celu wytypowano kocioł wsadowy małej mocy. Opalany słomą w kostkach. Dokonano analizy technicznej i elementarnej spalanego paliwa, a także określono przedziały wilgotności poszczególnych kostek. Opisano system pomiaru temperatury, dedykowany do określenia dynamiki jej rozkładu, a także opisano punkty pomiarowe, charakterystyczne dla wytypowanej jednostki. Przedstawiono wyniki szeregu czasowego poziomu temperatury dla trzech cykli. Na podstawie zebranych danych określono okres pojedynczego cyklu spalania wsadu, a także wyodrębniono i opisano charakterystyczne etapy wspomnianego cyklu. Kotły wsadowe na paliwo stałe, charakteryzują się wysoką bezwładnością cieplną. Opisano trudności ze sposobem sterowania procesem spalania, wynikające z niejednorodności parametrów paliwa oraz konstrukcji kotła. Sposób regulacji i sterowania procesem spalania w tych jednostkach, staje się zasadniczym wyzwaniem projektowo-technologicznym mającym na celu efektywne przetworzenie i energetyczne wykorzystanie paliwa, a znajomość dynamiki procesu jest kluczowa do ich opracowania.
EN
This paper presents the characteristics of the combustion process of straw. To achieve this aim a low-power batch boiler was selected, burning (combusting) straw cubes. Technical and elemental analyses of fuel combustion were carried out. and humidity ranges for individual cubes were specified. Temperature measurement system dedicated to determining the dynamics of its distribution was described, and the measurement points characteristic for given units were also described. The results of time series analyses of temperature levels for three cycles are provided. Based on the obtained data time of a single cycle of batch combustion was specified, and the characteristic stages of that cycle were defined and described. Batch boilers for solid fuel have a high thermal inertia. Difficulties related to controlling the combustion processes resulting from the heterogeneity of the fuel parameters and boilers' design were described. The method of regulating and controlling the combustion process in these units becomes a major challenge of design and technology, aimed at efficient transformation and utilization of fuel energy and understanding the dynamics of the process is crucial to their development.
3
Content available remote Prediction of thermal performance of double-glazed solar collector
EN
Solar energy heating system designers need estimates of energy amounts incident on collector surfaces in order to correctly size systems. Most collectors are tilted, but usually the only solar radiation data available refer to horizontal surfaces. The paper presents an approach to determine thermal parameters such as fluid temperature and efficiency of a double-glazed solar collector tested in north-western part of Algeria. Based on meteorological parameters collected during the year 2006, the study examines the validity of predicted performance of the tested solar collector when only one measured parameter is available, the global-horizontal radiation H[h] measured with Black and White pyranometer and obtained by the national meteorological institute of Algeria.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.