EN
The paper analyses how cooling water temperature affects the performance of an EPR nuclear power plant. At higher cooling water temperatures, the power output and efficiency of the system are lower. One of the factors that influence the performance of a nuclear power plant is its geographical location, since mean water temperatures are lower in the northern part of Europe than in its southern part. Although the nature of changes and the trend related to the effect of cooling water temperatures are known, the quantitative effect has to be determined on a case-by-case basis. A power plant with most likely pressurized water reactors (PWR) is to be built in Poland, which is why a state-of-the-art EPR pressurized water reactor design was selected as a subject of the present analysis. Depending on the location of this power plant, various cooling water temperatures to cool down its condensers, and therefore various operating conditions of the cooling system can be achieved. It is important to note that due to the smaller available enthalpy drop in the turbine of an EPR unit compared to the turbines of conventional units, steam cooling conditions play a vital role in this case. To analyze how the temperature affects the performance of the power unit, a model of an EPR power plant was developed using the Ebsilon software.
PL
W artykule dokonano analizy wpływu temperatury wody chłodzącej na osiągi elektrowni jądrowej z reaktorem typu EPR. Wraz ze wzrostem temperatury wody chłodzącej następuje spadek mocy i sprawności układu. Osiągi elektrowni jądrowej zależą m.in. od położenia geograficznego, ponieważ na północy Europy średnie temperatury wody są niższe niż na południu Europy. Charakter zmian i tendencja wpływu temperatury wody chłodzącej są znane natomiast ilościowy wpływ należy określać indywidualnie dla każdej elektrowni. W Polsce ma zostać wybudowana elektrownia najprawdopodobniej z reaktorami PWR, dlatego do analizy wybrano jedną z najnowszych technologii z reaktorami typu wodno-ciśnieniowego typu EPR. W zależności od lokalizacji tej elektrowni możliwe do osiągnięcia są różne wartości temperatury wody chłodzącej skraplacze EJ a więc i różne warunki pracy układu chłodzenia. Warto podkreślić, iż ze względu na mniejszy rozporządzalny spadek entalpii w turbinie bloku jądrowego EPR, w stosunku do turbin bloków konwencjonalnych, warunki chłodzenia pary odgrywają tutaj istotną rolę. W celu przeprowadzenia analizy wpływu tej temperatury na osiągi bloku został stworzony model elektrowni z reaktorem EPR w programie Ebsilon [1].
EN
Although PWR reactors make up the large majority of the world's nuclear power plants, BWR reactors also have a share in this industry. It is difficult to find data on the performance of a BWR power plant in off-design and variable load conditions in the literature. Therefore, the paper presents how cooling water temperature affects the efficiency and power output of a BWR unit. The qualitative effect of changes and the trend related to the effect of cooling water temperature on the performance of the power plant are known, but the quantitative effect has to be determined for specific power units. Depending on the location of the nuclear power plant, various temperatures of cooling water for use in condensers and thus various operating conditions of the cooling system can be achieved. To analyze how cooling water temperature affects the performance of the power unit, a model of a BWR power plant was developed using the Ebsilon software. The model was based on data provided in [1] concerning LaSalle County Nuclear Generating Station. Calculations showed that within the examined range of cooling water temperatures at the condenser inlet between 10 and 28oC the gross power output of the unit decreases by 91.405 MW and the gross efficiency drops by 2.773 percentage points.
3
EN
In this paper the influence of changing cooling water parameters on condenser operation has been presented. The analysis has been carried out for varying cooling water temperature and flow rate, for various thermal loads of the condenser, based on the test data as measured by independent measuring instruments. The test was carried out on an extraction-condensing turbine with rated power output over 100 MW. The influence of cooling parameters on condenser pressure, efficiency and parameter 5, as the condenser operation characteristic parameters, was tested. It has been shown that the lowest pressure in the condenser for a given steam load is obtained at the lowest temperature and the highest mass flow rate of cooling water. The cooling water temperature was being increased by changing the cooling tower operation setup, simulating the cooling conditions over the entire year. The cooling water flow rate was reduced by throttling the flap at the inlet to the condenser.
PL
W artykule przedstawiono wpływ zmiany parametrów wody chłodzącej na pracę skraplacza parowego. Analizę wykonano dla zmiennych temperatur oraz przepływu wody chłodzącej dla różnych obciążeń cieplnych skraplacza, opierając się na danych pomiarowych zmierzone niezależną aparatura pomiarową. Badania przeprowadzono na turbinie upustowo-kondensacyjnej o mocy nominalnej ponad 100 MW. Analizowano wpływ parametrów chłodzenia na ciśnienie w skraplaczu, sprawność oraz parametr 5, jako parametry charakterystyczne pracy wymiennika. Pokazano, że najniższe ciśnienie w skraplaczu dla danego obciążenia parowego uzyskuje się przy najniższej temperaturze oraz największym przepływie wody chłodzącej. Badania wykonywano w okresie zimowym. Temperaturę wody chłodzącej podwyższano przez zmianę konfiguracji pracy chłodni kominowej, symulując warunki chłodzenia w okresie całego roku. Przepływ wody chłodzącej zmniejszano przez dławienie klapą na wlocie do skraplacza.