Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  temperatura odbicia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Thermographic cameras are becoming increasingly popular in all kinds of diagnostic testing aiming to assess the technical state of thermal power engineering machinery, equipment and installations. The cameras provide thermograms that enable identification of various irregularities, including thermal bridges. However, it can be observed that their accuracy and reliability depend substantially on the conditions in which tests are carried out. Industrial thermographic testing, especially in thermal power engineering, is one of the most difficult procedures. Apart from the advantages of this particular technique, this paper presents an analysis of the effect of the conditions in which tests are performed on the obtained results. Attention is drawn to parameters characterizing the environment and the tested element surface, such as emissivity, reflected temperature, distance between the camera and the object, air temperature, etc. The sources of errors in the testing and in the interpretation of thermograms are indicated. Methods are also presented that enable elimination of irregularities, which improves the accuracy of the final results.
PL
Kamery termowizyjne są coraz częściej wykorzystywane w różnego rodzaju badaniach diagnostycznych mających na celu ocenę stanu technicznego maszyn, urządzeń i instalacji eksploatowanych w energetyce cieplnej. Uzyskiwane za ich pomocą termogramy pozwalają identyfikować różne nieprawidłowości, a także mostki termiczne. Można jednak zauważyć, że w badaniach termowizyjnych istotne znaczenie mają warunki, w jakich są one przeprowadzane. Te przemysłowe, w tym szczególnie w energetyce cieplnej, należy zaliczyć do trudnych. W artykule, obok wskazania zalet takich badań, przedstawiono analizę wpływu warunków, w jakich są one realizowane. Zwrócono uwagę na parametry charakteryzujące otoczenie i powierzchnię badanego elementu, jak np.: współczynnik emisyjności, temperatura odbicia, odległość kamery od obiektu, temperatura powietrza. Wskazano na źródła błędów podczas wykonywania tych badań i interpretacji termogramów. Podano sposoby eliminacji nieprawidłowości, co zwiększa dokładność wyników końcowych.
EN
The mathematical simulation of a plate fin and tube heat exchanger is presented in this paper. The simulation of the transient operation of the heat exchanger was carried out using a general numerical model that was previously developed by the authors. The Reynolds number of the water flowing inside the tubes varied in the range from 4000 to 12000. A detailed analysis of the transient response of a heat exchanger to sudden increase in water mass flow rate and the simultaneous reduction in air flow velocity was modelled. Heat transfer correlations for air and water were determined based on the experimental data. Unknown parameters appearing in the relationships for the Nusselt numbers on the airand water-sides were estimated using the least squares method. A set of partial differential equations for the temperature of water, air, tube wall, and fins was solved using the finite volume method. The results of the numerical simulations of a heat exchanger using experimentally determined air and water-side heat transfer formulas for the calculation of heat transfer coefficients were compared with the experimental data. Excellent agreement between computation results (air and water temperatures at the outlet of the heat exchanger) and experimental results was obtained.
PL
Przedstawiona została symulacja matematyczna wymiennika ciepła z rur ożebrowanych. Symulacja nieustalonej pracy wymiennika przeprowadzona została za pomocą modelu matematycznego opracowanego wcześniej przez autorów. Liczba Reynoldsa po stronie wody zmieniała się w zakresie od 4000 do 12 000. Szczegółowa analiza zmian temperatury została przeprowadzona dla przypadku nagłego wzrostu strumienia masowego płynu z jednoczesnym obniżeniem prędkości powietrza. Korelacje na współczynniki wnikania ciepła dla powietrza i wody określono na podstawie danych doświadczalnych. Nieznane parametry, które pojawiają się w równaniach na liczbę Nusselta dla powietrza i wody wyznaczono za pomocą metody najmniejszych kwadratów. Układ równań różniczkowych cząstkowych umożliwiający wyznaczenie temperatury wody, powietrza, ścianki rury i żeber zostały rozwiązane z użyciem metody objętości skończonej. Wyniki numerycznej symulacji pracy wymiennika z użyciem współczynników wnikania ciepła wyznaczonych z korelacji na liczby Nusselta od strony powietrza i wody porównano z danymi eksperymentalnymi. Uzyskano bardzo dobrą zgodność wyników obliczeń i pomiarów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.