Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  tablets
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Statins drugs are thought to be among the most prescribed drugs worldwide for the treatment of hypercholesterolaemia. A simple and reliable RP-HPLC method has been successfully employed for simultaneously separating and qualifying three statin drugs including atorvastatin, rosuvastatin and simvastatin in pharmaceutical tablets. The optimal conditions were mobile phase 50:50 (v/v) (formic acid pH 2.50: ETOH), column temperature 40.00 °C, detection wavelength 238.00 nm, and flow rate 1.00 mL/min. The proposed method has been validated based on the ICH guidelines in terms of linearity, precision, accuracy, and limit of detection and limit of quantification. The linear range investigated 2.0–80.0, 4.0–100.00, and 12.00–120.00 µg/mL for rosuvastatin, atorvastatin and simvastatin respectively with coefficients of determination (R2) within the range of 0.9993–0.9995. The LOD and LOQ for rosuvastatin, atorvastatin and simvastatin were (1.57, 4.76 µg/mL), (1.87, 5.66 µg/mL), (3.46, 10.49 µg/mL) respectively. In addition, in order to evaluate the feasibility of the method developed, it was employed towards the quantification of the pharmaceutical tablets for the analytes investigated and excellent recovery was obtained.
EN
The objective of the current research is to understand the degradation behavior of avanafil under different stress conditions and to develop a stability-indicating high-performance liquid chromatography (HPLC) method for simultaneous determination of degradants observed during degradation. Avanafil tablets were exposed to acid, base, water, oxidative, thermal, and photolytic degradation conditions. In acid, oxidative, thermal, and humidity degradation, significant degradation was observed. All the degradants observed during degradation were separated from known impurities of avanafil by using reverse-phase (RP)-HPLC. Mobile phase A, 0.1% trifluoro acetic acid and triethylamine in water, and mobile phase B, water and acetonitrile in the ratio of 20:80 (v/v), were used at a flow rate of 1.2 mL/min in gradient elution mode. Separation was achieved by using Inertsil ODS 3 column (3 μm, 4.6 mm × 250 mm) at 45 °C. Peak responses were recorded at 245 nm. Method capability for detecting and quantifying the degradants, which can form during stability, was proved by demonstrating the peak purity of avanafil peak in all the stressed samples. Mass balance was established by performing the assay of stressed sample against reference standard. Mass balance was found >97% for all the stress conditions. The developed analytical method was validated as per International Conference on Harmonization (ICH) guidelines. The method was found specific, linear, accurate, precise, rugged, and robust.
4
Content available Innowacyjne technologie w medycynie i farmacji
PL
Zastosowanie nowoczesnych technologii w medycynie i farmacji pozwala na coraz szybszą i skuteczniejszą diagnostykę oraz terapię wielu chorób. Do innowacyjnych należy np. drukowanie narządów, tkanek i tabletek w technologii 3D (w 2015 roku FDA zaaprobowała pierwszą drukowaną tabletkę zawierającą levetiracetam). Wyspecjalizowane roboty chirurgiczne są wykorzystywane w zabiegach chirurgicznych na odległość. Dzięki eliminowaniu drżenia rąk, ich użycie stanowi przyszłość w chirurgii i będzie coraz powszechniejsze. W poniższej pracy omówiono wykorzystanie potencjału druku 3D w medycynie i farmacji oraz zastosowania robotyki do wykonywania zabiegów chirurgicznych. Przedstawione zostały również przykłady innowacyjnych wynalazków, które mogą być stosowane podczas operacji chirurgicznych oraz w leczeniu bólu i gojeniu się ran.
EN
The use of modern technologies in medicine and pharmacy results in more rapid and effective diagnosis and treatment of many diseases. The 3D printing method is one of the innovative solutions that may be implemented for preparing organs, tissues, and solid drugs (in 2015 the FDA approved the first tablet containing levetiracetam, produced by 3DP). Specialized surgical robots are used for remote surgery. They eliminate hand tremor and their use is more and more popular. The following paper discusses the potential use of 3D printing method in medicine and pharmacy, and the application of robotics to perform surgical procedures. We also demonstrated examples of innovative devices, which can be used for surgical operations and in the treatment of pain and wound healing.
5
EN
The aim of the study was a continuation of previously provided research on the tablets usability in the rehabilitation of old patients with cognitive disabilities after a brain stroke. First, the analysis of the pilot research results was provided. It gave a hope for possible rationalization of the rehabilitation process after proper improvement of the proposed mobile solution. Prototype examples of mobile rehabilitation applications were extended and integrated in the RehaMob - a single mobile solution. The mobile application includes six different types of tasks, which can be useful for stimulation and rehabilitation of language functions, short-term memory, etc. The RehaMob was made available again to the therapists in the rehabilitation center. Finally, the mobile application is used with good results in the therapy of patients with cognitive disabilities. The mobile solution is useful support for traditional rehabilitation process, but its influence to the rehabilitation progress is difficult to assess, because the RehaMob can be used only as additional tool.
EN
A simple and selective liquid chromatographic method was developed for the simultaneous determination of tenofovir disoproxil fumarate (TEN) and emtricitabine (EMT) in combined tablets. The method is based on separation of TEN and EMT on a Zorbax SB-C8 column, 5 μm, 4.6 × 250 mm, with a mobile phase consisting of 50 mM disodium hydrogen phosphate-acetonitrile (50:50, v/v). The mobile phase contains 0.1% triethylamine (TEA) and was adjusted to pH 6.0. Quantification of the analytes is achieved with diode array — ultraviolet detector (DAD-UV) at 260 and 280 nm for TEN and EMT, respectively, based on peak area. Different variables affecting the method were carefully investigated and optimized. Reliability and analytical performance of the proposed method, including linearity, range, precision, accuracy, and detection and quantitation limits, were statistically validated. The high-performance liquid chromatography (HPLC) method was successfully applied for determination of each drug in their binary tablets.
PL
Z reguły pierwszym krokiem jest poddanie tabletki procesowi homogenizacji w odpowiedniej mieszaninie rozpuszczalników. W zależności od zastosowanej techniki oznaczenia wymagane są takie kroki jak dodatkowe rozcieńczenie próbki lub jej odpipetowanie. W większości laboratoriów powyższe etapy przeprowadzane są na drodze manualnej, co skutkuje pojawieniem się efektu przenoszenia próby, zanieczyszczeniem krzyżowym, a w konsekwencji niepowtarzalnością wyników. Ponadto czynności manualne są czasochłonne, żmudne i uzależnione od wielu różnych czynników.
EN
The first step is always the through homogenisation of the tablet in a suitable solvent mixture. Depending on the determination technique applied, steps such as additional dilution or pipetting are required. In most labs these steps are carried out manually, which can results in carryover or erratic results, as the time-consuming and tedious manual operations are influenced by many different circumatances.
8
Content available remote Rapid determination of nifuroxazide in tablets by near-infrared spectroscopy
EN
A novel method of quantification of nifuroxazide in pharmaceutical tablets by near-infrared ' reflectance spectroscopy was elaborated. The analysis was based on a S1MCA model gene- ; rated for pulverized nifuroxazide tablets and a set of calibration standards prepared by j mixing nifuroxazide with starch (weight percent of nifuroxazide 0-100%). Linear relationship between the principal component PCI calculated for the NIR reflectance spectra of the calibration standards and the contents of nifuroxazide was established. The calibration plot obtained this way allowed for quantification of nifuroxazide content in pharmaceutical tablets. Additionally, NIR reflectance spectra of the calibration standards were converted ' into 2nd derivatives. A number of analytical wavelengths were selected, for which separate calibration plots were constructed. Results of quantification of nifuroxazide in tablets using these plots were comparable to those obtained by the PC 1 method. Both versions of the NIR reflectance method of quantification of nifuroxazide content in tablets were simple, fast, and sufficiently accurate for routine analysis.
PL
Opracowano nową metodę ilościowego oznaczania nifuroksazydu w tabletkach farmaceutycznych za pomocą spektroskopii w bliskiej podczerwieni w odbiciu. Analiza opierała się na modelu SIMCA, utworzonym dla sproszkowanych tabletek i zestawu próbek kalibracyjnych, przygotowanych poprzez zmieszanie nifuroksazydu ze skrobią (O do 100% wagowych nifuroksazydu). Stwierdzono występowanie zależności liniowej między główną składową PCI, obliczoną dla widm próbek kalibracyjnych w bliskiej podczerwieni a zawartością nifuroksazydu. Otrzymana w ten sposób krzywa kalibracyjna umożliwiła oznaczenie ilościowe nifuroksazydu w tabletkach farmaceutycznych. Ponadto przekształcono widma próbek kalibracyjnych w 2-gie pochodne. Wybrano kilka analitycznych długości fal, dla których wykreślono osobne krzywe kalibracyjne. Wyniki ilościowego oznaczenia nifuroksazydu w tabletkach przy użyciu tych krzywych były porównywalne z wynikami uzyskanymi metodą PCI. Obie wersje metody oznaczania nifuroksazydu w tabletkach za pomocą spektroskopii w bliskiej podczerwieni w odbiciu okazały się proste, szybkie i wystarczająco dokładne do rutynowych analiz.
EN
Cyclic voltammograms of donepezil hydrochloride (donepezil HC1, DPH) recorded on a hanging mercury drop electrode in Britton-Robinson universal buffer of pH < 10 contai-ninglO % (v/v) methane! exhibited a single 2-electron irreversible cathodic peak corresponding to reduction of C=O bond. Adsorption of DPH on the mercury electrode surface was detected; each adsorbed molecule was found to occupy an area of 0.83 nm2. Based on the adsorptive behaviour of DPH on the mercury electrode surface, a simple and reliable square-wave adsorptive cathodic stripping voltammetric method for its determination in a bulk form at the trace level was developed. Limit of detection (LOD) and limit of quantification (LOQ) were respectively 9.3 x 10--1 mol L--1and 3.1 x 10-9mol L--1. The described method was validated with respect to linearity, precision, accuracy, specificity, robustness,and inter-laboratory precision. It was successfully applied to the determination of DPH in its pharmaceutical formulation — Aricept tablets and in DPH-spiked human serum (LOD = 1.5 x 10Q mol L-1 and LOQ = 5 x 10-9 mol L-9).No electroactive interferences from endogenous substances or excipients present in human serum or tablets, respectively, were found. This means that the proposed method does not require any extraction step prior to drug analysis, which makes the procedure superior over most of the reported methods for determination of DPH.
PL
Na cyklicznych woltamperogramach chlorowodorku donepezilu (DPH) otrzymanych na wiszącej, kroplowej elektrodzie rtęciowej w buforze Brittona-Robinsona o pH < I O, zawierającym 10% objętościowych metanolu pojawił się nieodwracalny, dwuelektronowy pik katodowy odpowiadający redukcji wiązania C=O. Stwierdzono, że na elektrodzie adsor-bowal się DPH, a każda zaadsorbowana cząsteczka zajmowała powierzchnię 0,83 nm2. : Wykorzystując fakt adsorbowania się DPH opracowano prostą i wiarygodną metodę oznaczania jego śladów. W metodzie wykorzystano zateżanie adsorpcyjne, katodowy striping i woltamperometrię kwadratowej fali. Granica wykrywalności i oznaczalności wynosiła dopowiednio: 9,3 x 10-10 i 3, l x 10-9 mol L-1. Metodę zwalidowano względem liniowości, precyzji, dokładności, specyficzności, odporności i międzylaboratoryjnej precyzji oraz z powodzeniem zastosowano do oznaczania DPH w tabletkach farmaceutycznych ,,Aricept"i w ludzkiej surowicy. W próbkach naturalnych granica wykrywalności i oznaczalności wzrosła odpowiednio do: 1,5 x 10-9 i 5,0 x 1-9 L-1. W badanych próbkach nie stwierdzono obecności innych elektroaktywnych składników, które mogłyby zakłócić analizę.Oznacza to. że proponowana metoda nie wymaga stosowania wstępnej ekstrakcji.
EN
A new, simple, accurate, and precise high-performance thin-layer chromatographic (HPTLC) method has been established for simultaneous analysis of eprosartan and hydrochlorothiazide in tablet formulations. Standard and sample solutions of eprosartan and hydrochlorothiazide were applied to precoated silica gel G 60 F 254 HPTLC plates and the plates were developed with benzene-methanol-formic acid 7:3:0.1 ( υ/υ ) as mobile phase. Detection and evaluation of chromatograms was performed densitometrically at 272 nm. The retention factors of eprosartan and hydrochlorothiazide were 0.76 and 0.57, respectively. The linear range was 4.8–43.2 μg per spot for eprosartan and 0.15–1.35 μg per spot for hydrochlorothiazide; the correlation coefficients, r , were 0.998 and 0.999, respectively. The method was validated and successfully used for analysis of the drugs in tablets.
EN
Electrochemical behavior of triamcinolone acetonide (TAA) has been studied by cyclic voltammetry at a hanging mercury drop electrode in universal buffers of pH 2-11. Due to the interfacial adsorption of triamcinolone acetonide onto the mercury surface, a fully validated square-wave adsorptive cathodic stripping voltammctric procedure was developed for its determination in the bulk form. Under optimized conditions, the stripping voltammetric peak current of triamcinolone acetonide showed a linear dependence on TAA concentration over the range 1 x 10-9-9 x 108 mol L-1. The mean percentage recovery of TAA was 99.84 š 0.64, the detection limit {LOD) was 3 x 10-10 mol L-1, and the quanlitation limit (LOQ) equaled 1 x 10-9 mol L-1. The proposed procedure was successfully applied in the determination of triamcinolone acetonide in Kenacort'K tablets and in human serum spiked with TAA without any pretreatment and/or time-consuming extractions prior to the analysis. LOD and LOQ corresponding to the determination of triamcinolone acetonide in spiked human serum were 7.5 x10-10 mol L-1 and 2,5 x 10-9mol L-1, respectively.
PL
Badano elektrochmiczne zachowanie acetonidu triamcinolonu (TAA) metodą cyklicznej woltamperometrii na elektrodzie rtęciowej w przedziale pH 2-11. Ponieważ stwierdzono adsorpcję TAA na powierzchni rtęci, do oznaczania tego związku zastosowano procedurę wykorzystującą wiszącą elektrodę rtęciową i adsorpcyjną, katodową woltamperometrię strippingową, W warunkach optymalnych otrzymano liniową zależność między wysokością piku woltamperometrycznego i stężeniem TAA w zakresie 1 x 10-9-9x 10-8mol L-1. Średni odzysk wyniósł 99.84 š 0.64 %, granica wykrywalności 3 x 10-9 mol L-1 a granica oznaczalności l x 10-9 mol L-1. Opacowaną procedurę zastosowano do oznac/.ania TAA w tabletkach Kenacort* i w ludzkiej surowicy krwi po dodaniu analitu. Nie było porzeby przeprowadzenia wstępnych działań chemicznych i ekstrakcji. Granicę wykrywalności i granicę oznaczalności w surowicy krwi oznaczono odpowiednio jako 7,5 x 10-10 mol L-1 i 2,5x 10 mol L-1.
12
Content available remote Determination of selenium in multicomponent pharmaceutical preperations
EN
Adsorptive stripping voltammetry (AdSV) and inductively coupled plasma mass spectro-metry (ICP-MS) have been applied to the determination of selenium in tablets. In AdSV method a con trolled-growth mercury drop electrode (CGMDE) served as the working electrode. 0.1 mo! L-1 HClO4 solution containing 1 μg of Cu(II) per 1 mL was used as the supporting electrolyte. Optimum parameters of AdSV determination were established.Detection limit for selenium was 50 pg mL-1. The method was successfully applied to the determination of selenium in tablets: Ekovit (Curtis Healthcare) and Rutinoscorbin Plus (Glaxo Wellcome). Strong matrix effects on the determination results of selenium in pharmaceutical products have been confirmed. For this reason standard addition method was applied. The determined content of selenium in Rutinoscorbin Plus and Ekovit tablets equalled to 7.35 μg/tablet and 20.35 μ.g/tablet, respectively. Corresponding relative standard deviations were 3.70% and 3.43%, respectively. Validation of both methods was carried out. The results obtained by AdSV were compared to those obtained by ICP-MS.Mass peak of 77Se was selected to determine the selenium content by ICP-MS. The method developed in this study provides accurate and precise determination of selenium in tablets without prior isolation of the analyte from the matrix.
PL
Oznaczano selen w tabletkach stosując metodę adsorpcyjnej woltamperometrii imvcrsyjnej (AdSV) oraz spektrometrii masowej z plazmą indukcyjnie sprzężoną (ICP-MS). Se(IV) oznaczano na kroplowej elektrodzie rtęciowej o kontrolowanym wzroście powierzchni (CGMDE) w 0.1 mol L-1 roztworze HClO4 z dodatkiem l μg Cu(II) na mL. Granica wykrywalności wynosiła 50 pg mL-1;. Opracowaną metodę AdSV zastosowano do oznaczenia zawartości selenu w tabletkach (Ekovit firmy Curtis Healthcare i Rutinoscorbin Plus firmy Glaxo Wellcome) po uprzedniej ekstrakcji analitu do wody. Badania wykazały duży wpiyw matrycy na wyniki oznaczania selenu w preparatach farmaceutycznych. Oznaczona zawartość selenu w preparacie Rutinoscorbin Plus wynosiła 7.35 μ/tabletkę (RSD 3.70%), a w preparacie Ekovit 20.35 μ/tabletkę (RSD 3.43%). Przeprowadzono walidację opracowanych metod. Porównano wyniki uzyskane metodami AdSV i TCP-MS. W metodzie ICP-MS całkowitą zawartość selenu wyznaczono z piku masowego izotopu 77Se. Opracowana metodyka przygotowania próbek i badań umożliwia rurynowe oznaczanie seienu w preparatach farmaceutycznych.
EN
The first-, second-, third- and fourth-order derivative spectrophotometric methods using the „peak-zero" (P-O) and „peak-peak" (P-P) techniques have been developed for the determination of cinoxacin and oxolinic acid in the model solutions and tablets. The calibration curves were linear (r = 0.9999) within the concentration ranges of 3.0-13.0 ug ml(-1)' and 1.0-10.0 ug mL(-1) for cinoxacin and oxolinic acid, respectively. The precision (RSD%) was better than 2.0 for cinoxacin and 0.5 for oxolinic acid. The procedure was simple and fast, and provided one with reliable results.
PL
W prezentowanej pracy zastosowano metodę spektrofotometrii pochodnej I-go, II-go, III-go i IV-go rzędu z użyciem techniki „pik do piku" (P-P) i „pik do lini podstawowej" (P-O) celem oznaczenia cynoksacyny i kwasu oksolinowego w roztworach modelowych i tabletkach. Wyznaczone krzywe kalibracji wykazują przebieg prostoliniowy (r = 0.9999) w badanym zakresie stężeń: 3.0-13.0ugmL (-1) i 1.0-10.0 ugml(-1) odpowiednio dla cynoksacyny i kwasu oksolinowego. Wartości względnego odchylenia standardowego (RSD) wynoszące ok. 2.0% i 0.5% odpowiednio dla wymienionych leków świadczą o dobrej precyzji opracowanych metod. Proponowane procedury analityczne są proste i szybkie, zaś rezultaty zadowalające.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.