Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  system wielomaszynowy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Control and modelling of multi-machine power system stabilizer with FACTS
EN
The Multi-machine system controlled and modelling using the FACTS-PSS controller is one of the most recently application to control the active or reactive power flow transmission line, also to incorporate them with power system stabilizer (FACTS-PSS). The flexible alternating current transmission system (FACTS) as new technology based on high-advances in power electronics in high switching frequency semi-conductor, Control theory and microprocessors technology, as Thyristor Controlled Series Compensator (TCSC), Static Var Compensator (SVC), those static devices controller designed for consolidating network efficiency, reliability, controllability, high quality demand, and power transfer capability of AC transmission systems.
PL
System wielomaszynowy sterowany i modelowany za pomocą sterownika FACTS-PSS jest jedną z najnowszych aplikacji do sterowania linią przesyłową przepływu mocy czynnej lub biernej, również w celu połączenia ich ze stabilizatorem systemu elektroenergetycznego (FACTS-PSS). Elastyczny system przesyłu prądu przemiennego (FACTS) jako nowa technologia oparta na zaawansowanych rozwiązaniach energoelektronicznych w półprzewodnikach wysokiej częstotliwości przełączania, teorii sterowania i technologii mikroprocesorowej, jako Tyrystorowy Kompensator Szeregowy (TCSC), Kompensator Statycznych Warstw Statycznych (SVC), te sterowniki urządzeń statycznych przeznaczone do konsolidacji wydajności sieci, niezawodności, sterowalności, wysokiej jakości zapotrzebowania i zdolności przenoszenia mocy systemów przesyłowych prądu przemiennego.
2
Content available remote Modeling and control of multimachines system using fuzzy logic
EN
This work is devoted to modeling and vector control by fuzzy logic of a multimachines system connected in series. A six-phase asynchronous machine connected in series with a three-phase asynchronous machine fed by a single inverter and controlled independently. Thanks to the powerful means of calculation, which made possible the control of such a system and this allows its integration in applications where the constraints of space and weight require a particular attention.
PL
W artykule opisano zastosowanie układu fuzzy logic do sterowania wielomaszynowym systemem sześciofazowej maszyny asynchronicznej I trójfazowej maszyny asynchronicznej polączonych szeregowo.Do sterowania każdej z maszyn użyto niezeleżnego przekształtnika.
EN
This paper presents a method of behaviour model control (BMC) combined with fuzzy logic and a seven-level six-phase inverter to achieve mainly a high performance and to increase the robustness of the vector control and to keep its performances despite the presence of perturbations (parameters variations, abrupt load variations, etc.) of a series-connected two motor six phase drive system with single inverter supply. The idea of the proposed control is to induce adding supplementary control inputs, which yield the process to follow the model. The best of feature of this control design is that it achieves the same performances as the Field Oriented Control without the need for heavy and expensive gain tuning. The effectiveness of the proposed behaviour model control in conjunction with the fuzzy logic is confirmed through the application of different load torques for wide speed range operation. Comparison between fuzzy behaviour model control, fuzzy logic controller (FLC) and conventional controller (PI) of the proposed two-motor drive is provided. The simulation results confirm also that, the validity and effectiveness of the control strategy proposed in both terms of performance and robustness (rotor inertia variations J1=5J1nominal) of the provision of such an adaptive control for electrical drives with the two machines of the system.
PL
W artykule opisano wykorzstanie metody BMC (behaviour model control) wspartej logiką romytą w siedmiopoziomowym sześciofazowym przekształtniku w celu osiągnięcia dobrych parametrów I zwiększenia odpoeności w obecności zakłóceń. Osiągnioęto podobne parametry co w przypadku stosowania metody FOC (field oriented control) bez koniczności stosowania dopasowania wzmocnienia.
4
Content available remote Coordinated design of PSS and TCSC based on Fuzzy controller using global signals
EN
This paper presents a modified chaotic gravitational search algorithm (CGSA) as a novel heuristic algorithm for coordinate design of fuzzy logic controller-based thyristor controlled series capacitor (FLC-TCSC) and power system stabilizers (PSSs) in multi-machine power system. The coordinate design of PSS and FLC-TCSC damping controllers is converted to a single optimization problem with the time-domain objective function which is solved by the proposed CGSA algorithm which has strong ability for finding the most optimistic results. By minimizing the employed fitness function in which oscillatory characteristics between areas are included, the interactions among the FLC-TCSC controller and PSS under transient conditions in the multi-machine power system are enhanced. The generator speed and the electrical power are chosen as global input signals. The system performance is assessed through the time multiplied absolute value of the error (ITAE), Eigenvalues and figure of demerit (FD) analysis performance indices. The robustness is tested by considering several operating conditions to establish the superior performance with the proposed controller over the other stabilizers.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.