The paper deals with transient analysis of grounding systems wind turbines.To improve the accuracy of lightning impact studies on wind power grid generation, it is necessary to develop faster, more accurate simulation tools and to use increasingly sophisticated models .First, we identify and characterize the different parameters that influence the behaviour of grounding systems, particularly when they broadcast a lightning current. To do this, an electromagnetic model from the theory of antennas equation’s by – Euler method with incorporating soil ionization allows to represent the behavior of an earthing system inthe frequency domain.. Different configurations with several complexity degrees have been simulated. To validate the obtained results, we compare our TLM results to the measurement results and FDTD simulation..A comparison between two different configurations of wind turbine grounding systems with comparing the transient potential, impulse impedance, and DC component of transient impedance between the two configurations when buried in soil. A number of illustrative computational examples are presented in the paper
PL
W celu poprawy dokładności badań wpływu wyładowań atmosferycznych na produkcję energii wiatrowej konieczne jest opracowanie szybszych i dokładniejszych narzędzi symulacyjnych oraz wykorzystanie coraz bardziej wyrafinowanych modeli. W pierwszej kolejności identyfikujemy i opisujemy różne parametry wpływające na zachowanie się systemów uziemienia, zwłaszcza gdy przekazują one prąd piorunowy. W tym celu opracowany został model elektromagnetyczny z teorii równań Eulera z wykorzystaniem jonizacji gruntu, który pozwala na przedstawienie zachowania się systemu uziemienia w dziedzinie częstotliwości. Symulowane są różne konfiguracje o kilku stopniach złożoności. W celu walidacji uzyskanych wyników, porównujemy nasze wyniki TLM z wynikami pomiarów i symulacji FDTD.Porównanie dwóch różnych konfiguracji uziemienia turbiny wiatrowej z porównaniem potencjału przemijającego, impedancji impulsowej i składowej stałej impedancji przemijającej pomiędzy tymi dwiema konfiguracjami, gdy są one zakopane w gruncie.
EN
Marconite is often used as alternative material to improve the performance of earth grounding system. This study aims to investigate of the physical and mechanical behaviour of conductive aggregate derived from Marconite namely, the electrical resistivity, water absorption, and crushing strength. In addition, similar tests were also conducted on mortar aggregate for comparison. The resistivity of aggregates were measured using soil box method. Test results showed that the electrical resistivity, water absorption, and crushing strength of both aggregates varied with time. These values were found to be stabilised after approximately after 14 days. The electrical resistivity for aggregates containing Marconite were found to be 39.2 Ω.m, far lower than 12700 Ω.m obtained for mortar-based aggregates. Similarly, the water absorption for Marconite aggregates were greater compared to mortar aggregates. On the other hand, the crushing strength for Marconite aggregates was to be lower. Incorporating Marconite significantly improved the electrical resistivity behaviour while maintaining acceptable mechanical properties crucial for electrical grounding purposes.
3
Content available remote Transient performance of interconnected wind turbine grounding systems
EN
We analyze the transient grounding characteristics of interconnected wind turbine grounding systems, for fast rising current pulses. By increasing the number of wind turbines, influences on harmonic impedance and transient potential are examined for different soil characteristics and different locations of excitation. Simulations are performed using simple model of grounding system that neglects the foundation reinforcement. The influence of such simplification for isolated wind turbines is analyzed in previous papers. Here we extend the previous analysis for interconnected wind turbines and we look at the possibilities for optimization of the transient analysis of extended grounding systems in wind farms.
XX
Przeanalizowano w pracy charakterystyki stanów przejściowych uziemień turbin wiatrowych dla szybkiego narastania impulsów prądowych. Przy wzroście liczby turbin wiatrowych zbadano wpływu na impedancje harmoniczną oraz stan przejściowy dla różnych charakterystyk gleby i różnych lokalizacji wzbudzenia. Przeprowadzono symulacje przy użycie prostego modelu uziemienia, który zaniedbuje wzmocnienie fundamentów. Wpływ takiego uproszczenia dla pojedynczych turbin przebadany został w e wcześniejszych publikacjach. W tym artykule rozszerzono poprzednia analizę na połączone turbiny oraz skierowano uwagę na możliwości optymalizacji analizy stanów przejściowych rozbudowanych systemów uziemienia na farmach wiatrowych.