Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  system testujący
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Modelowy system do badań napędów elektromechanicznych
EN
The article presents the modelled system for tests and certification of the electromechanical actuators which is used in the active safety devices that increase the level of technical and fire safety. The important elements of the fire protection are: safety devices for removal of smoke and heat from the building, and devices for ensuring permeability of the evacuation tracts, and the actuators for opening the windows and valves for de-smoking and aeration. The developed system allows running tests on the actuators to determine on their load characteristics, durability and resistance to increased or decreased temperatures. The configuration of the control-measurement module includes the PC computer with implemented specialised software that cooperates with the PLC controller and allows to all necessary measurement operations and control functions that were earlier developed from the research procedures.
2
Content available remote Stacjonarne jednostanowiskowe stacje wzorcownicze
PL
Opisano urządzenia do testowania liczników energii elektrycznej i aktualny stan w zakresie stacjonarnych jednostanowiskowych stacji wzorcowniczych. Analiza schematów blokowych stacji i wad ich fizycznych realizacji umożliwiła sformułowanie wymagań na stacjonarną jednostanowiskową stację nowej generacji. Przedstawiono koncepcję w postaci schematu i konstrukcji stacji nowej generacji na przykładzie projektu stacji typu LS3, przeznaczonej do badania wszystkich rodzajów liczników energii elektrycznej.
EN
This article presents an idea of a new generation of a Stationary Single Position Three Phase Meter Test Bench for electricity meter testing. Different kind of Meter Test Equipment for testing of electricity meters and Polish complex proposal of the Meter Test Equipment pyramid is described. Actual state of the Stationary Single Position Meter Test Stations, analysis of their block scheme and disadvantages of physical realizations makes possible to formulate the requirements for modern Stationary Single Position Meter Test Bench. Idea, including the scheme and construction of the new generation Stationary Single Position Meter Test Bench model LS3 is presented.
PL
W artykule opisano właściwości mierników parametrów sieci energetycznej i analizatorów jakości tej sieci. Przedstawiono zarówno wymagania metrologiczne jak i jakościowe niezbędne do prawidłowej analizy w oparciu o obowiązujące normy. Sprecyzowano wymagania na sprzęt, który jest niezbędny do sprawdzania mierników i analizatorów. Opisano system testujący złożony z programowanego źródła sygnałów i oprogramowania na komputer klasy PC. Na przykładzie analizy zapadów i zaników napięcia przedstawiono sposób wykorzystania trójfazowego kalibratora mocy do testowania analizatora jakości energii. Automatyzacja procesu sprawdzania wieloparametrowych mierników pozwala na szybką i wiarygodną ocenę właściwości testowanego przyrządu pomiarowego.
EN
In the paper features of power network parameters meters and power quality analyzers are described. Fig.2 shows the structure of Power Quality Analyzer. A special attention is paid to the data recording and result evaluation which differentiate meters from analyzers. An example of the result evaluation according to the standard EN-50160 in a synthetic and detailed form is presented in Fig. 3. Then, there are given the accuracy and quality requirements (Tab. 1) for the correct analysis according to the standards (IEC 61000-4-30). There are also defined the requirements for equipment for testing meters and analyzers. Signal sources should have: voltage, current, phase shift, frequency and harmonics contents programmable in time. The technical parameters of C300 Three Phase Calibrator and Tester are given in Tab.2. The testing system consisting of a programmable signal source and PC software is also presented in the paper. An exemplary test of a power quality analyzer by means of a three phase calibrator illustrates the problem. Automation of testing multi-parameters analyzers enables the reliable evaluation of the tested device features.
PL
W artykule przedstawiono strukturę uniwersalnego systemu testującego oraz przykład zastosowania takiego systemu do wzorcowania, kalibracji i sprawdzania dokładności na przykładzie stanowiska do testowania rejestratora mikroprocesorowego.
EN
It is necessary to test an accuracy of measuring devices. Testing systems are used to improve testing process. There are many kinds of microprocessor-based measuring devices. Differences between them depend on the kind and number of inputs and outputs as well as the functions realised by the device blocks. A structure of a universal, microprocessor-based measuring device is shown in Fig. 1. Most of the measuring devices are tested in dedicated testing systems. There are some differences between them. A structure of a universal testing system is presented in Fig. 2. The use of the testing system is illustrated by the example of testing a microprocessor-based recorder. Fig. 3 shows a view of the exemplary recorder and Fig. 4 - a view of the recorder without a transporter for paper rewinding. The power on/off switch and the keyboard with an LCD display to program the recorder parameters can be seen in this picture. This recorder has one universal input to measure signals from many kinds of sensors. The keyboard is used to select a sensor. A view of the testing system during its activation is shown in Fig. 5. The system consists of a calibrator - 1, a meter - 2, a switch module - 3, a connection adapter - 4, a system control unit - 5 and a testing device - 6. Fig. 6 shows a testing algorithm implemented in the described testing system.
PL
W artykule przedstawiono przykładową strukturę systemu testującego urządzenia Elektroenergetycznej Automatyki Zabezpieczeniowej (EAZ). Aby układ mógł poprawnie pracować niezbędne jest dobranie optymalnych parametrów. Artykuł przedstawia porównanie metody tradycyjnej (sprawdzenie kolejnych kombinacji możliwych parametrów) z metodą wykorzystującą sztuczną inteligencję, która ułatwia użytkownikowi podjęcie decyzji dotyczących zadawanych wartości. Przeprowadzone badania pozwolą ocenić, która z prezentowanych metod jest lepsza i wydajniejsza.
EN
The effective and unfailing work of energetic system depends on Automatic Security Devices. It is a very important question how to test the ASD effectively. This publication contains the testing system for this device. It is also important to find the correct parameters for this system. It is a difficult and long task to check all the possible parameters, The Genetic Algorithm seems to be fit for it. There are two methods to find the correct parameters for the system and to test the ASD effectively, These methods are going to be compared. The first one looks for the parameters and checks different combinations of them to choose finally the best ones. The Genetic Algorithms are the second method. The Genetic Algorithm seems to be fit to choose the optimal parameters to tost the system. This is a quick method but it is not as accurate as a first method yet.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.