Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  symulator ruchu stawu biodrowego
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents the construction of a hip joint movement simulator intended for friction and wear studies of hip joint endoprostheses. The endoprosthesis head is mounted on a special base in the lower position with a neck-shaft angle of 135°, while the acetabular cup of the endoprosthesis is mounted in the upper part in the mounting head with an inclination angle of 45°. The production of three heads (responsible for the anteversion angle of the acetabulum) and three special bases (responsible for the antitorsion angle of the head) with different fixing angles of the components of the hip joint endoprosthesis, made it possible to carry out tribological tests with nine variants of alignment settings. The hip joint endoprosthesis tester is designed to simulate the following movements: flexion and extension as well as loads occurring in the human hip joint while walking. The subject of friction and wear studies were hip joint endoprostheses with a head diameter of 44 mm, made of high-carbon Co28Cr6Mo alloy. For each of the nine variants of endoprosthesis component alignment settings, average values of the coefficient of friction were calculated based on the recorded values of the friction. torque.
PL
W artykule przedstawiono konstrukcję symulatora ruchu stawu biodrowego, przeznaczonego do badań tarciowo-zużyciowych endoprotez stawu biodrowego. Głowa endoprotezy mocowana jest na cokole w dolnym położeniu z kątem szyjkowo-trzonowym 135°, natomiast panewka endoprotezy zamontowana jest w górnej części w głowicy mocującej z zachowaniem kąta inklinacji 45°. Wykonanie trzech głowic (odpowiedzialnych za kąt antywersji panewki) oraz trzech cokołów (odpowiedzialnych za kąt antetorsji głowy) różniących się kątami osadzenia komponentów endoprotezy stawu biodrowego umożliwiło przeprowadzenie testów tribologicznych z dziewięcioma wariantami ustawień. Tester endoprotezy stawu biodrowego przeznaczony jest do symulacji ruchów: zgięcia i wyprostu oraz obciążeń występujących w stawie biodrowym człowieka podczas chodu. Przedmiotem badań tarciowo-zużyciowych były endoprotezy stawu biodrowego o średnicy głowy 44 mm, wykonane z wysokowęglowego stopu Co28Cr6Mo. Dla każdego z dziewięciu wariantów ustawień komponentów endoprotezy obliczone zostały średnie wartości współczynnika tarcia w oparciu o rejestrowane wartości momentu tarcia.
2
Content available Stand for tribological testing of hip endoprostheses
EN
The paper presents a new construction of hip-joint simulator. The SBT-01.2 simulator is designed for conducting tribological testing of hip endoprostheses based on ISO 14242-1, which specifies the requirements for the range of motion and load characteristics of the friction pair (femoral head vs. acetabular cup) during one test cycle. The construction of the simulator is based on the anatomical structure of the human hip joint. The prosthesis acetabulum is mounted in the upper part of the mounting head while maintaining the inclination angle relative to the axis of the socket to the direction of the loading force. The head of the prosthesis is mounted on a pin embedded in the bottom, movable base. After placing a special sleeve on the lower base, liquid lubricant is applied on the head-cup tribological system. The employed software enables continuous control, online visualization, and data recording. During testing, parameters such as lubricant temperature, instantaneous loading force, friction torque, and the number of cycles are recorded.
PL
W artykule przedstawiono nową konstrukcję symulatora ruchu stawu biodrowego. Symulator SBT-01.2 przeznaczony jest do realizacji badań tribologicznych endoprotez stawu biodrowego w oparciu o normę ISO 14242-1, która określa wymogi dotyczące zakresu ruchów i charakterystyki obciążenia pary trącej (głowa-panewka) w czasie jednego cyklu badawczego. Konstrukcja symulatora oparta została na anatomicznej budowie stawu biodrowego człowieka. Panewka endoprotezy zamontowana jest w górnej części w głowicy mocującej z zachowaniem kąta inklinacji osi panewki względem kierunku przyłożenia siły obciążającej. Głowa endoprotezy mocowana jest na trzpieniu osadzonym w dolnej, ruchomej podstawie. Po założeniu specjalnego rękawa na dolnej podstawie układ tribologiczny głowa-panewka zalewany jest cieczą smarującą. Zastosowane oprogramowanie umożliwia stałą kontrolę, wizualizację online i zapis danych. Podczas testu rejestrowane są takie parametry jak: temperatura cieczy smarującej, chwilowa wartość siły obciążającej, moment siły tarcia i aktualna liczba cykli.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.