Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  survival time
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
An original simplified procedure to estimate the remaining service time of corroded shell of an on-the-ground steel tank used to store liquid fuels is presented in this paper. Current corrosion progress trend, identified a’posteriori based on the obligatory technical condition monitoring, is extrapolated to the future tank service time under the assumption that the conditions of service would not change and no renovation or modernization works would be undertaken. Failure probability understood as exhaustion of the capability to safely resist the loads applied due to the corrosion progress constitutes the measure of the sought uptime. For comparative purposes several effective inference methods have been proposed for the same input data, based on formally qualitatively different but corresponding description measures. It has been shown, that in the analysis of this type the representative values, usually expressed as quantiles of probability distributions describing random variables in use, need not be specified to verify the safety condition. The proposed algorithm is based on fully probabilistic considerations, and those, according to Authors’ opinion, by their nature lead to more reliable, and at the same time, objective estimates.
PL
Przedstawiono uproszczoną, autorską procedurę szacowania pozostającego czasu zdatności skorodowanej powłoki naziemnego użytkowanego zbiornika stalowego wykorzystywanego do magazynowania paliw płynnych. W proponowanym algorytmie postępowania dotychczasowy trend postępu korozji, identyfikowany a posteriori na podstawie pomiarów dokonywanych w ramach obowiązkowych ocen stanu technicznego, zostaje ekstrapolowany na czas przyszłego użytkowania zbiornika, przy założeniu że sposób jego wykorzystania nie ulegnie zmianie i nie będą prowadzone jakiekolwiek prace remontowe lub modernizacyjne. Miarą oceny poszukiwanego czasu zdatności jest narastające wraz z postępem korozji prawdopodobieństwo awarii rozumianej jako wyczerpanie możliwości bezpiecznego przenoszenia obciążeń. Awaria nie oznacza przy tym natychmiastowego zniszczenia obiektu ale stan, w którym monitorowane prawdopodobieństwo osiągnęło poziom graniczny, niemożliwy do zaakceptowania przez użytkownika. Dla tych samych danych wejściowych, w celach porównawczych, zaproponowano różne sposoby efektywnego wnioskowania, oparte na formalnie jakościowo odmiennych ale odpowiadających sobie miarach opisu. Potwierdzono, że w tego typu analizie do weryfikacji warunku bezpieczeństwa nie ma potrzeby specyfikacji jakichkolwiek wartości reprezentatywnych, wyznaczanych na ogół jako kwantyle rozkładów prawdopodobieństwa opisujących poszczególne zmienne losowe, w szczególności losowe obciążenie i losową nośność rozważanej powłoki. Proponowany algorytm opiera się bowiem na wnioskowaniu w pełni probabilistycznym, a to, zdaniem autorów, ze swej natury pozwala oceniającemu na uzyskanie bardziej wiarygodnych a przy tym obiektywnych oszacowań. Prezentowana procedura została zweryfikowana numerycznie na przykładzie prognozy opracowanej dla istniejącego stalowego zbiornika paliwowego z dachem pływającym, zlokalizowanego w jednej z baz paliwowych Polski południowej.
EN
Regression models of censored survival data are often required to handle the cases, where information on the dependent (response) variable is only available as intervals, within which the actual values are located. We report on implementation and some preliminary tests of a new general method for regression with an interval-censored response variable. This method is based on minimization of a convex piecewise-linear (CPL) criterion function introduced earlier for perceptron-type classifier design. The presented interval regression method (CPL- IR) can handle arbitrary pattern of exact and left-, right-, or interval-censored data in one flexible computational framework.
3
Content available remote Zachowanie poli(chlorku winylu) w pożarach
PL
Omówiono aktualny stan wiedzy na temat roli PVC w pożarach. Przeanalizowano toksyczność dymu, w tym rolę CO, HC1 i dioksyn, a także znaczenie szybkości wydzielania ciepła i jej związek z czasem przeżycia ludzi - ofiar pożaru. Przedstawiono wyniki raportów komisji powołanych przez rząd Północnej Nadrenii-Westfalii (Niemcy) w sprawie dwóch wielkich pożarów z udziałem PVC: fabryki recyklingu tworzyw sztucznych w Lengerich (1992 r.) i lotniska w Dusseldorfie (1996 r.). Na podstawie wyników najnowszych badań stwierdza się obecnie, że PVC jest materiałem, który nie stwarza i nie zwiększa ryzyka pożaru. Nie powoduje on też zwiększonego zagrożenia dla zdrowia i życia, lecz przeciwnie - ze względu na małą szybkość wydzielania ciepła przedłuża czas przeżycia ludzi. Toksyczność dymu z PVC jest tego samego rzędu, co z innych materiałów naturalnych i syntetycznych, ponieważ toksyczność atmosfery pożaru determinowana jest prawie wyłącznie ilością tlenku węgla. Dokonana przez kompetentne komisje analiza dużych pożarów wskazuje, że PVC w pożarze nie powoduje tworzenia istotnych ilości dioksyn; nie zanotowano też zatruć dioksynami lub wielopierścieniowymi węglowodorami aromatycznymi w pożarach z udziałem PVC.
EN
The behavior of PVC on fire is described. Smoke toxicity involving that of CO, HC1 and dioxins, and evolution of heat and its connection with survival, are discussed. The Reports of the German Commissions set up by the Government of North Rhine and Westphalien to study the 1992 Plastics Recycling Plant at Lengerich and the 1996 Dusseldorf Airport fires are summarized. Most recent studies have shown PVC neither to create nor to increase the hazards for health and life; the low rate of heat release does even increase the time for survival. The PVC smoke is as toxic as is the smoke of other natural and synthetic materials; it is determined primarily by the carbon oxide content. Analysis of large fires showed PVC to form insignificant amounts of dioxins; so far, intoxication with dioxins or PAH has never been reported in PVC fires.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.