Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  surface coverage
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The relation between the diurnal sum of atmospheric precipitation and the diurnal volume of rainwater runoff from four experimental hardened surfaces was the subject of a pilot study conducted within the area of the Departmental Agro- and Hydrometeorology Observatory in Wrocław. The selection and the structure of the experimental surfaces were preceded with an inventory-taking of the coverage of hardened surfaces within a Wrocław housing estate with high-rise multifamily buildings. That estate was the second location, next to the area of the Observatory, at which the study presented here was conducted. The surfaces included in the experiment were roof surfaces P1 and P2 covered with heat-sealable roll roofing, surface APB made of gravel-filled openwork concrete plates, and tarmac surface AS. The pilot study was conducted during the period from April to November, 2014. During that period, depending on the type of experimental surface, from 81 to 87 days with atmospheric precipitation were analysed. The mean values of the rainwater runoff coefficients for the eightmonth period were 0.77, 0.77, 0.33 and 0.67 for surfaces P1, P2, APB and AS, respectively. The range of variability of mean values of the coefficients of rainwater runoff from the experimental surfaces in a month is presented by the following relation: APB > P1 > AS > P2. The study did not reveal any direct effect of the number of rainfall days in a month on the value of the coefficient of determination describing the correlation between the diurnal sums of precipitation and the diurnal volumes of rainwater runoff.
PL
Zależność między sumą dobową opadu atmosferycznego a dobową objętością spływu powierzchniowego z czterech eksperymentalnych powierzchni utwardzonych była przedmiotem badań pilotażowych prowadzonych na terenie Wydziałowego Obserwatorium Agro- i Hydrometeorologii we Wrocławiu (Wrocław-Swojec). Wybór i budowa powierzchni eksperymentalnych zostały poprzedzone inwentaryzacją pokrycia powierzchni utwardzonych w obrębie wrocławskiego osiedla mieszkaniowego o zabudowie wielorodzinnej wysokiej, będącego drugą, poza obszarem Obserwatorium, lokalizacją, w której prowadzone są badania. Dwie z powierzchni eksperymentalnych stanowią powierzchnie dachowe P1 i P2 pokryte papą termozgrzewalną, natomiast kolejne dwie to powierzchnia APB wykonana z ażurowych płyt betonowych wypełnionych materiałem żwirowym oraz powierzchnia asfaltowa AS. Badania pilotażowe wykonywano w okresie od kwietnia do listopada 2014 roku. W tym czasie, w zależności od rodzaju powierzchni doświadczalnej przeanalizowano od 81 do 87 dni, w których wystąpił opad atmosferyczny. Wartości średnie współczynników spływu powierzchniowego z okresu ośmiu miesięcy wyniosły: 0,77, 0,77, 0,33 i 0,67 odpowiednio dla P1, P2, APB i AS. Zakres zmienności średnich wartości współczynników spływu z powierzchni doświadczalnych w miesiącu (ψs) przedstawia następująca zależność: APB > P1 > AS > P2. Na podstawie badań nie stwierdzono bezpośredniego wpływu liczby dni z opadem w ciągu miesiąca na wartość współczynnika determinacji opisującego zależność między sumami dobowymi opadu i dobowymi objętościami spływu wody opadowej z powierzchni doświadczalnych.
2
Content available remote Influence of frother concentration on bubble dimensions and rising velocities
EN
Influence of á-terpineol concentration on local and terminal velocities of bubbles, their dimensions and shapes was studied within solution concentration range 1ź 10-5 to 1ź 10-3 mole/dm3. Bubble behaviour was monitored using CCD camera with stroboscopic illumination and high speed camera Speedcam 512. Variations of the bubble local velocity and its deformation were determined as a function of distance from the capillary orifice and analysed in terms of adsorption coverage at interface of the departing bubble. Two kinds of dependencies of the bubbles local velocities on distance were observed. At low á-terpineol concentrations the profiles of the bubble local velocity showed maximum at distances ca. 5-20 mm from the capillary orifice, prior to reaching a value of the terminal velocity. No maximum was observed at distilled water and á-terpineol concentrations c>0.0001 mole/dm3. It was found that á-terpineol adsorption coverage of ca. 6% was the minimum needed to assure the full immobilization of the bubble surface and the lowering of bubble terminal velocity by ca. 60% as result of it.
PL
Badano wpływ stężenia .-terpineolu na prędkości lokalne i graniczne baniek, ich rozmiar oraz deformacje kształtu. Wyznaczono profile prędkości lokalnych baniek i kształtów w funkcji odległości od kapilary (.=0.07mm) na której wytwarzano bańki przy pomocy precyzyjnej pompy strzykawkowej. Pomiary wykonano dla roztworów .-terpineolu w zakresie stężeń od 1*10-5 do 1*10-3 mole/dm3. Ruch baniek był monitorowany za pomocą dwóch kamer, zbierających informacje o położeniu i kształcie z częstotliwościami 100 i 1182 Hz. Stwierdzono występowanie kilku różnych etapów w ruchu baniek wypływających w roztworach .-terpineolu. Bańki bezpośrednio po oderwaniu od kapilary przyspieszają, po czym w zależności od badanego stężenia ich prędkości osiągają stałą wartość graniczną (woda i roztwory .-terpineolu o dużym stężeniu) lub też obserwowane jest przejście przez maksimum i stopniowe spowolnienie prędkości do innej, często znacznie mniejszej niż maksymalna, wartości prędkości granicznej (stężenia mniejsze od 0.0001 mol/dm3). W przypadkach niskich stężeni równocześnie ze zmianami profili prędkości lokalnych są obserwowane dynamiczne zmiany kształtu baniek. Wartości prędkości granicznych unoszących się baniek spadają wraz ze wzrostem stężenia .- terpineolu od 34.8š0.03 cm/s w wodzie destylowanej do 15.4š0.03 cm/s w roztworze .-terpineolu o stężeniu 0.001 mol/dm3 . Stwierdzono, że stopień pokrycia adsorpcyjnego na powierzchni bańki jest czynnikiem decydującym o profilach prędkości lokalnych baniek, jak i ich deformacjach. Największe zmiany występują w obszarze niskich stężeń .-terpineolu, przy których stopień pokrycia adsorpcyjnego zmienia się w zakresie 0-10%. Pokrycie adsorpcyjne .-terpineolem .=6% jest minimalnym pokryciem niezbędnym dla całkowitego unieruchomienia powierzchni bańki w wyniku którego graniczna prędkość baniek ulega znacznemu zmniejszeniu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.