Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 16

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  surface charge
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Surface charging and particles aggregation ascharite are investigated through Zeta potential measurement, XPS analysis, SEM analysis and dissolution experiments. The results show that more Mg2+ are removed from ascharite surface after dissolution, which confirms that incongruent dissolution of ions in the case of certain ionic substances like rmagnesium ions, hydroxyl groups and borate ions can lead to a net charge on surface. Isomorphous substitution of Fe3+ for Mg2+ is also regarded as one factor that causes surface charging behavior, which is in consistent with the experimental data. The dissolution process is analyzed to show more details about the dissolution reactions. The disparity in the bonding energy of B–O and Mg–OH surface groups and the difference in free energy of hydration of surface groups are considered to be the basic reason that lead to incongruent dissolution. Eventually, the effect of surface potential on particles aggregation is analyzed by DLVO theory, indicating that dissolution of ascharite has a detrimental effect on particles dispersion.
PL
Przedstawiono wyniki adsorpcji wybranych jonów metali nieżelaznych na sproszkowanych skorupach jaj kurzych. Skuteczność działania sorbenta jest wyższa w roztworach chlorkowych niż w roztworach siarczanowych. Stwierdzono, że istnieje możliwość usunięcia ponad 70% jonów Fe(ll) i Fe(lll) z roztworu chlorkowego i ok. 55% jonów Fe(ll) i 63% jonów Cu(ll) z roztworu siarczanowego. W przypadku pozostałych jonów (Cd(ll), Co(ll), Mn(ll), Ni(ll), Zn(ll)) efektywność działania sorbenta w badanych warunkach wyniosła poniżej 50%. Niezależnie od rodzaju soli, kinetyka procesu podlega opisowi reakcji pseudo-drugiego rzędu. Sorpcja zachodzi w wyniku wymiany jonowej, a adsorbent charakteryzuje się ujemnym ładunkiem powierzchniowym.
EN
Results of adsorption ofselected non-ferrous metalś ions on powdered chickenś egg shells were presented. Effectiveness of the sorbent was hi-gher in chloride than in sulfate solutions. It was found that more than 70% Fe(ll) and Fe(lll) ions from the chloride solution and about 55% Fe(ll) and 63% Cu(ll) ions from the sulfate solution can be removed. For remaining ions (Cd(ll), Co(ll), Mn(ll), Ni(ll), Zn(ll)l adsorption efficiency was below 50%. Regardless of the salt type, kinetics of the process is described by pseudo-second order reaction eąuation. Sorption occurs by ion exchange and the adsorbent is characterized by a negatiwe surface charge.
3
Content available remote Ocena rozkładu ładunku na powierzchni elektretów
PL
Przedstawiono zagadnienia związane z oceną stanu naelektryzowania materiału polimerowego. Badania wykonano na próbkach z policzterofluoroetylenu (PTFE), poddając je wcześniej elektryzacji metodą wyładowania koronowego w układzie powietrznej triody. Napięcie zastępcze elektretów badano metodą kompensacyjną. Ocenę jednorodności rozkładu ładunku elektrycznego na powierzchni elektretów wyznaczano z wykorzystaniem indukcyjnej sondy pomiarowej.
EN
We present issues related to the assessment of static electricity in the polymeric material. Tests were performed on samples of polytetrafluoroethylene (PTFE), before subjecting them to the electrification of the corona discharge in anair triode system. Equivalent voltage ofelectrets studied by compensation method. The evaluation of uniformity of distribution of the electric charge on the surface of electrets determined using the inductive probe.
EN
The paper presents the results of research on the influence of the electric charge deposited on composite insulators models on DC flashover voltage. The influence of the charge on the flashover voltage was observed on the level of 0-18%. That influence depended on the insulator position. There was no visible influence (occurrence of any regularity) of core and housing material on a flashover voltage.
PL
Przedstawiono wyniki badań wpływu ładunku elektrycznego zgromadzonego na modelach izolatorów kompozytowych na napięcie przeskoku przy narażaniu napięciem stałym. Wpływ ładunku na napięcie przeskoku był na poziomie 0-18%. Wpływ ten zależał od położenia izolatora. Nie było żadnego widocznego wpływu (wystąpienia jakichkolwiek regularności) materiału rdzenia i powłoki na napięcie przeskoku.
EN
The cell-material interaction is significantly influenced by the physicochemical properties of the material surface, including its electrical charge. In this study, the effect of the surface polarity of ferroelectric LiNbO3 single crystals on the adhesion, growth and osteogenic differentiation of human bone marrow mesenchymal stem cells was investigated. The cells were cultured on the normal-to-plane poled and in-plane poled plates resulting in positive, negative and zero surface charge. The number of initially adhering cells on day 1 after seeding, their spreading, shape, and their metabolic activity, production of type I collagen, activity of alkaline phosphatase and mineralization in the following days of cultivation (days 6 and 20) were comparable on all three tested surfaces. However, significant differences were found in the expression of mRNA for type I collagen, alkaline phosphatase and osteocalcin, i.e. an early, medium-term and late arkers of osteogenic cell differentiation, respectively. On day 20, the expression of type I collagen was significantly lower in cells on negatively-charged than on non-charged surfaces. Moreover, the expression of alkaline phosphatase and osteocalcin was higher in cells on positively-charged than on negatively-charged surfaces. These differences were generally more pronounced in standard cell culture medium than in osteogenic medium, which could, at least partly, mask the influence of the material surface properties on the cell behaviour. Thus, positively-charged LiNbO3 surfaces seemed to be more suitable for the osteogenic differentiation of bone marrow mesenchymal stem cells than the negatively-charged surfaces.
EN
This study examines changes that occur in yeast cell surface properties during physical, chemical and mechanical treatment and their potential impact on the biomass uptake capacity for lead. As a result of biomass treatment, the negative surface charge decreased and relative hydrophobicity increased. A strong negative correlation was discovered between the negative surface charge of variously modified yeast cells and their relative hydrophobicity. Despite the lower negative surface charge of treated in comparison to untreated yeast cells, the treated biomass had higher lead sorption capability. No relationship was found between the effectiveness of lead sorption by treated biomass and its surface charge or relative hydrophobicity.
7
Content available remote Zanik ładunku na izolatorach kompozytowych
PL
Zbadano proces zaniku ładunku powierzchniowego na cylindrycznych kompozytowych izolatorach zawierających różne kombinacje materiałów rdzenia i płaszcza. Izolatory zostały poddane „punktowej” elektryzacji za pomocą wyładowania koronowego przy napięciu stałym. Wyniki badań wykazały zależność szybkości zaniku ładunku od materiału płaszcza jak i rdzenia przy czym transport ładunku ma miejsce głównie w płaszczu. Stwierdzono również wpływ interfazy rdzeń-płaszcz na szybkość zaniku ładunku.
EN
Surface charge decay process was examined on cylindrical composite insulators models with various combinations of core and housing materials. Insulator models were subjected to “point” electrification by DC corona discharge. The results showed that the rate of charge decay depend on the material of the core and the housing wherein the charge transport takes place primarily in the housing. It was also found the influence of core-housing interphase on the rate of charge decay.
EN
Intravascular stenting of atherosclerotic coronary arteries is a life-saving, widely used procedure in interventional cardiology. Adverse clinical outcomes such as restenosis high-light the importance of meeting the excellent biocompatibility by cardiovascular implants. Many attempts have been made to improve the safety profile of implant surface. We for the first time developed the photoactive intravascular titania-based nanomaterials for the application as cardiovascular stent coating. Photoactive biomaterial deposited on the cardiovascular stent surface demonstrated promising features, making it an excellent substrate for endothelial cells growth and proliferation. The biocompatibility of these coatings has been compared with 316L stainless steel surfaces typically used in commercial coronary stents production. The results of the study proved that the innovative titania- based coatings have better biocompatibility characteristics than the 316L stainless steel and in regard of its antithrombotic potential provided protection against restenosis. Further-more, the titania coating supported endothelial cells attachment and proliferation, and induced prolonged plasma recalcification time in comparison with stainless steel surface. Innovative photoactive titania coating can be an important factor to prevent the process of the restenosis in the place of implantation.
PL
W pracy przedstawiono wyniki pomiarów wytrzymałości elektrycznej izolatorów ceramicznych, zarejestrowano przebiegi prądów oraz napięć podczas prób. Badane obiekty zmodyfikowano powierzchniowo poprzez nałożenie warstw zmieniających ich rezystywność powierzchniową. Określono wpływ modyfikacji powierzchni na zarejestrowane przebiegi jak i charakter wyładowań. Wyznaczono napięcie przeskoku na badanych próbkach. Zastosowanie warstw półprzewodzących o rezystywności na poziomie 1010–1011 podnosi napięcie przeskoku o ok. 17%. Zarejestrowano obrazy wyładowań powierzchniowych podczas prób napięciem impulsowym o dodatniej biegunowości. Na podstawie wyników pomiarów oraz obserwacji wyładowań stwierdzono, że istotną rolę w ich trajektorii może odgrywać ładunek gromadzony na powierzchni próbki.
EN
The results of electrical strength investigations of a ceramic insulators was showed. The current and voltage graphs during impulse high voltage tests were recorded. The spices were modified by coatings which change the surface resistivity of the samples. Effect of surface modification on the current and voltage figures was described. The results of the flashover voltage with the use of impulse voltage was showed. Using the layers with surface resistivity in order of 1010 - 1011 increases flashover voltage about 17%. The figures of discharges during impulse voltage tests with positive polarization were recorded. Based on the electrical strength results and discharge observation the impact of surface charge on the discharge trajectory was showed.
PL
W artykule opisano mechanizm przeskoku elektrycznego na powierzchni próbek wykonanych z poliamidu oraz poliamidu z dodatkiem włókna szklanego, stosowanych na osłony izolacyjne beziskiernikowego ogranicznika przepięć. Podczas prób napięciem impulsowym stwierdzono występowanie przeskoków powierzchniowych, które prowadzą do trwałego uszkodzenia ograniczników przepięć. Podczas wyładowań powstają rozwarstwienia pomiędzy stosem warystorowym a izolacją, które powodują obniżenie wytrzymałości powierzchniowej Wykazano rolę ładunku powierzchniowego w rozwoju wyładowania powierzchniowego. Stwierdzono, że włókno szklane wykorzystane w poliamidowej osłonie izolacyjnej ogranicznika, może powodować zwiększenie jej wytrzymałości elektrycznej oraz mechanicznej. W pracy wyznaczono napięcia przeskoku na próbkach. Zarejestrowano obrazy wyładowań powierzchniowych przy napięciu impulsowym, przemiennym oraz stałym obu biegunowości. Na ich podstawie określono wpływ zawartości włókna szklanego na napięcie przeskoku, charakter wyładowania powierzchniowego oraz określono rolę ładunku powierzchniowego determinującego przeskok.
EN
This paper describes the mechanism of an electric flashover on the surface of polyamide samples and samples of the polyamide with the glass fiber, which are used as an insulating housing of the metal oxide surge arrester. During the impulse voltage tests it was claimed that the surface flashovers occurring, which lead to the damage of the surge arresters. During the discharges, the stratification between varistors pile and insulating, which lead to lower surface strength are occurred. The role of a surface charge in the development of surface discharge was shown. It was found that the glass fiber used in polyamide housing of the surge arrester can be cause the increasing the electrical and mechanical strength. In this work the flashover voltage was measured. Pictures of the surface discharges by high impulse voltage tests, AC and DC tests were recorded. On the basis of this the impact of the glass fiber on the flashover voltage, the character of the surface discharge and role of the surface charge which determine the flashover was defined.
11
Content available remote Wyładowania elektryczne na granicy faz
PL
W artykule opisano mechanizm wyładowań powierzchniowych na granicy faz dielektryk stały - powietrze atmosferyczne. Przedstawiono wyniki pomiarow napięć przeskoku przy probach napięciem impulsowym wykonanych na płytkach porcelanowych z różnego rodzaju powłokami zewnętrznymi o różnej wartości rezystywności powierzchniowej. Na podstawie pomiarow natężenia pola elektrycznego, przed doprowadzeniem do przeskoku elektrycznego jak i po wystąpieniu wyładowania, pośrednio wykazano wpływ ładunku powierzchniowego na trajektorię wyładowań jak równiez wartości napięć przeskoku. Stwierdzono, że wykorzystanie jako powłoki lakieru półprzewodzącego o rezystywności powierzchniowej rzędu 1010 [omega] podnosi wartość napięcia przeskoku i obniża wartość natężenia pola elektrycznego od ładunku powierzchniowego, zmieniającego rozkład pola przy badanej próbce.
EN
This paper describes the mechanism of a surface discharges on the solid dielectric – atmospheric air boundary phase. The results of the flashover voltage, with the use of impulse voltage, on the ceramic samples with different coating and various surface resistivity, was showed. Based on electrical field measurements, before and after flashover, the impact on the discharge trajectory and flashover voltage, was showed. Using the semiconducting varnish layer with surface resistivity about 1010 [omega] as a coating, increase flashover voltage and decrease the electrical field from the surface charge, which change the electrical field distribution near the tested sample.
EN
The studies have been presented on spatial and temporal distributions of surface charge on samples of ethylene propylene diene monomer (EPDM) and silicon rubber (SIR). The charge was deposited from a positive impulse corona source located at 1 mm above the polymeric surfaces. During the experiments, the number of pulses and their voltage level were varied. It was observed that the spread of the charge over the surface of the samples as well as its magnitude were both increasing with increasing number of impulses applied. EPDM accumulated charge easier and had a longer relaxation time than SIR. A common feature frequently observed in both cases was that the resulting charge distributions had a saddle-like pattern. Performed computer simulations showed that this feature can be attributed to peculiarities of the corona charging in the considered system, which took place in a form of a burst corona, and the dynamics of the deposited charges could be related to burst corona pulses.
13
Content available remote Factors Affecting the Mechanism of Flashover in Metal Oxide Surge Arrester
EN
The paper describes the mechanism of an electric flashover on a boundary surface between a ceramic varistor and polyamide casing of a metal oxide surge arrester. The role of a surface charge in the development of surface discharge was shown. The surface flashovers lead to constant destruction of a varistor pile and to stratification of the surfaces which lower the electrical strength of the metal oxide surge arrester. It was found that this problem can be solved by means of covering the ceramic varistor surface with a semi-conducting layer which carry away the generated surface charge and compensate the distribution of a electric field along the boundary surface.
PL
W tym artykule opisano mechanizm przeskoku elektrycznego na powierzchni granicznej między ceramiką warystorową i poliamidową obudową odgromników tlenkowych. Wykazano rolę ładunku powierzchniowego w rozwoju wyładowania powierzchniowego. Przeskoki powierzchniowe prowadzą do trwałego niszczenia stosu warystorowego oraz tworzenia się rozwarstwień, które obniżają wytrzymałość elektryczną odgromnika. Stwierdzono, że problem może być rozwiązany przez pokrywanie powierzchni ceramicznych warystorów warstwą półprzewodzącą umożliwiającą odprowadzenie generowanego ładunku powierzchniowego i wyrównywanie rozkładu pola elektrycznego wzdłuż powierzchni granicznej.
EN
This paper presents studies on spatial and temporal distributions of surface charge on samples of Ethylene Propylene Diene Monomer (EPDM) and Silicon Rubber (SIR). The charge was deposited from a positive impulse corona source at 1 mm above the polymeric surfaces. During the experiments, the number of pulses and their voltage level were varied. It was observed that the spread of the charge over the surface of the samples as well as its magnitude were both increasing with increasing number of impulses applied. EPDM accumulated charge easier and had a longer relaxation time than SIR. A common feature frequently observed in both cases was that the resulting charge distributions had a saddle-like pattern. Performed computer simulations showed that this feature can be attributed to peculiarities of the corona charging proc the considered system, which took place in form of a burst corona, and the dynamics of the deposited charges could be related to burst corona pulses.
15
EN
The structures of the electrical double layer at the Al2O3-SiO2/NaClO4 interface with different alumina-to-silica ratios were interpreted using the surface complexation model. The surface charge and potential ζ of the system has been determined as a function of pH for 0.1, 0.01, and 0.001 mol/dm3 solutions of NaClO4. A significant difference in the pH values of IEP and point of zero charge was observed for Al2O3-SiO2 samples. The ionization and complexation constants have also been determined.
PL
Badania właściwości powierzchniowych tlenków mieszanych są ważne z praktycznego i teoretycznego powodu, ponieważ są szeroko rozpowszechnione w glebach i nowoczesnych technologiach np. jako katalizatory. Struktura podwójnej warstwy elektrycznej na granicy faz Al2O3-SiO2/NaClO4, z różną zawartością objętościową tritlenku glinu w badanych układach została zinterpretowana przy użyciu odpowiedniego modelu pwe. Określono gęstość ładunku powierzchniowego i wartość potencjału dzeta w zależności od pH dla następujących stężeń elektrolitu 0.1, 0.01 i 0.001 mol/dm3 NaClO4.Obliczono stałe jonizacji i kompleksowania metodą optymalizacji numerycznej dla poszczególnych układów oraz porównano wartości gęstości ładunku powierzchniowego wyznaczonego metodą miareczkowania potencjometrycznego do wyznaczonego teoretycznie.
EN
Some peculiar electret properties of fibrous polymer materials have been studied by complementary methods. The residual polarization has been proved to result from capture of free charge carriers on two main types of defects, namely oxygen-containing groups and the defects formed from violated permolecular structure. A spontaneous electrel charge is generated in the fibrous material at both melt blowing and melt spinning and its value depends on the process parameters. The forced polarization of fibers in an external electric field makes the electret effect more pronounced and adds a specific character to the polarizing charge relaxation.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.